A Sensitive and Reliable LC-MS/MS Method for the Determination of Ambroxol and its Application to a Pharmacokinetic Study in healthy Chinese Subjects

被引:0
|
作者
Wang, Yilin [1 ,2 ]
Zhao, Yingying [1 ,2 ]
Wu, Yingxiang [1 ,2 ]
Wang, Yan [1 ,2 ]
机构
[1] Dali Univ, Coll Pharm, Dali 671000, Peoples R China
[2] Yunnan Key Lab Screening & Res Anti Pathogen Plant, Dali 671000, Peoples R China
来源
LATIN AMERICAN JOURNAL OF PHARMACY | 2023年 / 42卷 / 03期
关键词
ambroxol; LC-MS; MS; pharmacokinetics; MASS-SPECTROMETRY METHOD; HUMAN PLASMA; HYDROCHLORIDE; AMOXICILLIN; VALIDATION; TABLET;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
. In the present study, a sensitive and reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for assessment of ambroxol pharmacokinetics in human plasma sample according to FDA guidelines. Ambroxol and propranolol (internal standard, IS) were extract-ed from plasma samples using liquid-liquid extraction (LLE) with ethyl acetate. Chromatographic separation was achieved on a Luna C18column (2.0 mm x 150 mm, 5 mu m) using acetonitrile-0.1% formic acid water as the mobile phase at a flow rate of 0.6 mL/min under gradient elution procedure. Quantification was performed by using an electrospray ionization (ESI) source in the positive ion mode, and the multiple reaction monitoring (MRM) conversions of m/z 379.0 -> 263.9 for ambroxol, and m/z 260.1 -> 116.1 for IS were conducted. Correla-tion coefficients > 0.9966 were achieved for all the calibration curves with linear regression. The intra-day and inter-day precisions of ambroxol were 6.9-9.1% and 1.2-14.4%, respectively, while the corresponding accuracies were-2.4-2.8% with high extraction recovery and little matrix effect. The method developed in the current study was successfully applied to the evaluation of pharmacokinetic study of ambroxol in healthy Chinese volunteers after single oral administration of salbutamol/ambroxol fixed-dose combination granules (containing 15 mg ambroxol). Compared with the other literature available for human plasma, the current study possesses many advantages, e.g. high sensitivity (LLOQ of 0.100 ng/mL for ambroxol), low cost (small plasma volume of 100 mu L), and a short chromatographic run time (4.0 min per sample).
引用
收藏
页码:636 / 642
页数:7
相关论文
共 50 条
  • [21] A simple and sensitive LC-MS/MS method for the determination of polyphyllin VII in rat plasma and its application to pharmacokinetic study
    Wang, Hao
    Han, Han
    Xu, Ying
    Yang, Yishun
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (05)
  • [22] A rapid and sensitive LC-MS/MS method for the determination of osthole in rat plasma: application to pharmacokinetic study
    Yun, Fei
    Kang, An
    Shan, Jinjun
    Zhao, Xiaoli
    Bi, Xiaolin
    Di, Liuqing
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (05) : 676 - 680
  • [23] Development and Validation of a Sensitive LC-MS/MS Method for Determination of Betamethasone in Human Plasma. Application to a Pharmacokinetic Study of Healthy Mexican Subjects
    Patino-Rodriguez, Omar A.
    Escobedo-Moratilla, Abraham
    Maria Martinez-Medina, Rosa
    Torres-Roque, Irma
    Martinez-Delgado, Maricela
    Perez-Urizar, Jose
    CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) : 2 - 8
  • [24] A sensitive LC-MS/MS method for determination of levamisole in human plasma: Application to pharmacokinetic study
    Tong, Liping
    Ding, Likun
    Li, Yan
    Wang, Zhirui
    Wang, Jingwen
    Liu, Yu
    Yang, Lin
    Wen, Aidong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (5-6): : 299 - 303
  • [25] A novel LC-MS/MS method for mepivacaine determination and pharmacokinetic study in a single-dose two-period crossover in healthy subjects
    Duan, Ruo-Wang
    Song, Jiong
    Li, Yu-Ping
    Xing, Chun-Gen
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2017, 45 (08) : 1605 - 1611
  • [26] Determination of tamsulosin in plasma of healthy Chinese male subjects by a novel and simple LC-MS/MS method and its application to pharmacokinetic studies
    Zhong, Maolian
    Wang, Xing
    Xiong, Wenqiang
    Liu, Yan
    Wang, Xiaosong
    Yi, Xiaoyi
    Zhang, Hong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1229
  • [27] Sensitive method for the determination of rocilinostat in small volume mouse plasma by LC-MS/MS and its application to a pharmacokinetic study in mice
    Gupta, Manish
    Dixit, Abhishek
    Devaraj, V. C.
    Zainuddin, Mohd
    Bhamidipati, Ravi Kanth
    Hallur, Mahanandeesha S.
    Dewang, Purushottam
    Rajagopal, Sridharan
    Rajagopal, Sriram
    Mullangi, Ramesh
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (07) : 1138 - 1144
  • [28] Simultaneous determination of atorvastatin and niacin in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Ravi, Vasu Babu
    Mullangi, Ramesh
    Inamadugu, Jaswanth Kumar
    Pilli, Nageswara Rao
    Gajula, Ramakrishna
    Ponneri, Venkateswarlu
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (11) : 1436 - 1443
  • [29] HIGHLY SENSITIVE LC-MS/MS METHOD FOR THE DETERMINATION OF CLOZAPINE IN RAT PLASMA: APPLICATION TO A PRECLINICAL PHARMACOKINETIC STUDY
    Haas, Sandra Elisa
    Brum, Liberato, Jr.
    de Andrade, Cristiane
    Azeredo, Francine Johansson
    Pigatto, Maiara
    Silva Torres, Bruna Gaelzer
    Guterres, Silvia Stanicuaski
    Dalla Costa, Teresa
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (20) : 2873 - 2883
  • [30] Determination of swertianolin in rat plasma by LC-MS/MS and its application to a pharmacokinetic study
    He, Jun
    Tian, Chengwang
    Ouyang, Huizi
    Adelakun, Tiwalade A.
    Yu, Bin
    Chang, Yanxu
    Pan, Guixiang
    Jiang, Linghuo
    Gao, Xiumei
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (10) : 1418 - 1422