Test-Retest Reliability and Convergent Validity of Piezoelectric Force Plate Measures of Single-Leg Sit-to-Stand Performance in Trained Adults

被引:3
作者
Makaraci, Yucel [1 ]
Nas, Kazim [1 ]
Ruiz-Cardenas, Juan D. [2 ]
Gunduz, Kerem [3 ]
Aydemir, Mustafa [3 ]
Orange, Samuel T. [4 ,5 ]
机构
[1] Karamanoglu Mehmetbey Univ, Fac Sports Sci, Dept Coaching Educ, Karaman, Turkiye
[2] Univ Catolica Murcia, Physiotherapy Dept, Fac Hlth Sci, Murcia, Spain
[3] Karamanoglu Mehmetbey Univ, Inst Hlth Sci, Dept Sports Sci, Karaman, Turkiye
[4] Newcastle Univ, Sch Biomed Nutrit & Sport Sci, Fac Med Sci, Newcastle Upon Tyne, Tyne & Wear, England
[5] Newcastle Univ, Newcastle Univ Ctr Canc, Newcastle Upon Tyne, Tyne & Wear, England
关键词
reliability; validity; functional strength; kinetic chain; limb symmetry index; lower extremity; unilateral jump; FUNCTIONAL PERFORMANCE; ASYMMETRY; STRENGTH; BALANCE; MUSCLE; POWER; VELOCITY; ABILITY;
D O I
10.1519/JSC.0000000000004489
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The single-leg sit-to-stand (STS) test has emerged as a promising method of assessing lower-limb functional strength and asymmetry. However, the reliability of its performance parameters on a force plate has not been explored. This study examined the test-retest reliability and convergent validity of the single-leg STS test performed on a piezoelectric-based force plate in trained subjects. Thirty trained male adults (age: 21.4 +/- 1.7 years) performed 3 separate single-leg STS days of testing to assess both intraday and interday reliability. Performance parameters included STS time, ground reaction force (GRF), and center of pressure (CoP) sway velocity. The relationship between single-leg STS parameters and unilateral countermovement jump (CMJ) variables was assessed for convergent validity. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were calculated for reliability analyses, and convergent validity was assessed with Spearman's correlation coefficient (rho). In the dominant leg, single-leg performance parameters showed moderate-to-excellent intraday reliability (ICC = 0.65-0.90, CV = 4.3-11.2%) and moderate interday reliability (ICC = 0.54-0.74, CV = 5.8-13.5%). In the nondominant leg, all single-leg STS performance parameters showed good intraday (ICC = 0.79-0.86, CV = 3.8-9.8%) and interday reliability (ICC = 0.75-0.82, CV = 4.6-9.7%). STS times in the dominant and nondominant legs were inversely related to unilateral CMJ velocity (rho = -0.47 and -0.38, respectively). CoP sway velocity in the nondominant leg showed positive correlations with unilateral CMJ power and velocity (rho = 0.38 and 0.54, respectively). In conclusion, the force plate-based single-leg STS test provides reliable measures of STS time, GRF, and CoP sway velocity in trained adults and could be used to assess lower-limb function and asymmetry.
引用
收藏
页码:2373 / 2380
页数:8
相关论文
共 30 条
  • [21] Concurrent and discriminant validity and reliability of an Android App to assess time, velocity and power during sit-to-stand test in community-dwelling older adults
    Juan D. Ruiz-Cárdenas
    Alessio Montemurro
    María del Mar Martínez-García
    Juan J. Rodríguez-Juan
    Aging Clinical and Experimental Research, 2023, 35 (8) : 1631 - 1640
  • [22] Concurrent and discriminant validity and reliability of an Android App to assess time, velocity and power during sit-to-stand test in community-dwelling older adults
    Ruiz-Cardenas, Juan D.
    Montemurro, Alessio
    del Mar Martinez-Garcia, Maria
    Rodriguez-Juan, Juan J.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2023, 35 (08) : 1631 - 1640
  • [23] Test-Retest Reliability of Single Leg Jump Performance Using the Drift Protocol in Division I Baseball Pitchers
    Bergquist, Amy M.
    Lebron, Modesto A.
    Mangum, L. Colby
    Stout, Jeffrey R.
    Fukuda, David H.
    JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2023,
  • [24] Sit-to-stand muscle power test: Comparison between estimated and force plate-derived mechanical power and their association with physical function in older adults
    Baltasar-Fernandez, Ivan
    Alcazar, Julian
    Rodriguez-Lopez, Carlos
    Losa-Reyna, Jose
    Alonso-Seco, Maria
    Ara, Ignacio
    Alegre, Luis M.
    EXPERIMENTAL GERONTOLOGY, 2021, 145
  • [25] Test-retest reliability and convergent validity of (R)-[11C]PK11195 outcome measures without arterial input function
    Pontus Plavén-Sigray
    Granville James Matheson
    Zsolt Cselényi
    Aurelija Jucaite
    Lars Farde
    Simon Cervenka
    EJNMMI Research, 8
  • [26] Test-retest reliability and convergent validity of (R)-[11C]PK11195 outcome measures without arterial input function
    Plaven-Sigray, Pontus
    Matheson, Granville James
    Cselenyi, Zsolt
    Jucaite, Aurelija
    Farde, Lars
    Cervenka, Simon
    EJNMMI RESEARCH, 2018, 8
  • [27] Norms, convergent validity, test-retest reliability, and practice effects for verbal fluency overall performance, clustering, and switching in Spanish-speaking children
    Filippetti, Vanessa Aran
    Gutierrez, Marisel
    Krumm, Gabriela
    CLINICAL NEUROPSYCHOLOGIST, 2024, 38 (07) : 1726 - 1755
  • [28] Test-retest Reliability, Convergent Validity, and Internal Consistency of the Persian Version of Fullerton Advanced Balance Scale in Iranian Community-dwelling Older Adults
    Sabet, Azar
    Azad, Akram
    Taghizadeh, Ghorban
    SALMAND-IRANIAN JOURNAL OF AGEING, 2016, 10 (04): : 18 - 28
  • [29] Construct validity and test-retest reliability of the Modified Agility T-Test in healthy adults A single-center cross-sectional study
    Zurcher, John
    Liechti, Seraina
    Degenfellner, Jurgen
    Pfeiffer, Fabian
    Bauer, Christoph
    PHYSIOSCIENCE, 2024, 20 (04) : 163 - 169
  • [30] RETRACTED: Test-Retest Reliability of Dynamic Balance Performance-Based Measures Among Adults With a Unilateral Lower-Limb Amputation (Retracted Article)
    Cardoso, Jefferson R.
    Beisheim, Emma H.
    Horne, John R.
    Sions, J. Megan
    PM&R, 2019, 11 (03) : 243 - 251