Comparison of intra- and inter-patient intensity standardization methods for multi-parametric whole-body MRI

被引:1
作者
Ceranka, Jakub [1 ,2 ]
Lecouvet, Frederic [3 ]
Michoux, Nicolas [3 ]
de Mey, Johan [4 ]
Raeymaekers, Hubert [4 ]
Metens, Thierry [5 ]
Vandemeulebroucke, Jef [1 ,2 ,4 ]
机构
[1] Vrije Univ Brussel, Dept Elect & Informat, Pleinlaan 2, Brussels, Belgium
[2] Imec, Kapeldreef 75, B-3001 Leuven, Belgium
[3] Univ catholique Louvain UCLouvain, Inst Rech Experimentale & Clin IREC, Clin Univ St Luc, Brussels, Belgium
[4] Univ Ziekenhuis Brussel, Dept Radiol, Brussels, Belgium
[5] Univ Libre Bruxelles ULB, ULB Hop Erasme, Dept Radiol, Brussels, Belgium
关键词
whole-body MRI; multi-parametric MRI; intensity standardization; average image population; REGISTRATION;
D O I
10.1088/2057-1976/acc80e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. To test and compare different intensity standardization approaches for whole-body multi-parametric MR images, aiming to compensate voxel intensity differences between scans. These differences, common for magnetic resonance imaging, pose problems in image quantification, assessment of changes between a baseline and follow-up scan, and hinder performance of image processing and machine learning algorithms. Approach. In this work, we present a comparison on the accuracy of intensity standardization approaches with increasing complexity, for intra- and inter-patient multi-parametric whole-body MRI. Several approaches were used: z-scoring of the intensities, piecewise linear mapping and deformable mapping of intensity distributions into established reference intensity space. For each method, the impact on standardization algorithm on the use of single image or average population distribution reference; as well as, whole image and region of interest were additionally investigated. All methods were validated on a data set of 18 whole-body anatomical and diffusion-weighted MR scans consisting of baseline and follow-up examinations acquired from advanced prostate cancer patients and healthy volunteers. Main results. The piecewise linear intensity standardisation approach provided the best compromise between standardization accuracy and method stability, with average deviations in intensity profile of 0.011-0.027 and mean absolute difference of 0.29-0.37 standard score (intra-patient) and 0.014-0.056 (inter-patient), depending on the type of used MR modality. Significance. Linear piecewise approaches showed the overall best performance across multiple validation metrics, mostly because of its robustness. The inter-patient standardization proved to perform better when using population average reference image; in contrary to intra-patient approach, where the best results were achieved by standardizing towards a reference image taken as the baseline scan.
引用
收藏
页数:14
相关论文
共 30 条
  • [1] MR image normalization dilemma and the accuracy of brain tumor classification model
    Alnowami, Majdi
    Taha, Eslam
    Alsebaeai, Saeed
    Anwar, Syed Muhammad
    Alhawsawi, Abdulsalam
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (03) : 33 - 39
  • [2] Assessment of Treatment Response by Total Tumor Volume and Global Apparent Diffusion Coefficient Using Diffusion-Weighted MRI in Patients with Metastatic Bone Disease: A Feasibility Study
    Blackledge, Matthew D.
    Collins, David J.
    Tunariu, Nina
    Orton, Matthew R.
    Padhani, Anwar R.
    Leach, Martin O.
    Koh, Dow-Mu
    [J]. PLOS ONE, 2014, 9 (04):
  • [3] Rapid automated measurement of body fat distribution from whole-body MRI
    Brennan, DD
    Whelan, PF
    Robinson, K
    Ghita, O
    O'Brien, JM
    Sadleir, R
    Eustace, SJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (02) : 418 - 423
  • [4] Computer-aided detection of focal bone metastases from whole-body multi-modal MRI
    Ceranka, Jakub
    Lecouvet, Frederic
    de Mey, Johan
    Vandemeulebroucke, Jef
    [J]. MEDICAL IMAGING 2020: COMPUTER-AIDED DIAGNOSIS, 2020, 11314
  • [5] Multi-atlas segmentation of the skeleton from whole-body MRI-Impact of iterative background masking
    Ceranka, Jakub
    Verga, Sabrina
    Kvasnytsia, Maryna
    Lecouvet, Frederic
    Michoux, Nicolas
    de Mey, Johan
    Raeymaekers, Hubert
    Metens, Thierry
    Absil, Julie
    Vandemeulebroucke, Jef
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1851 - 1862
  • [6] Registration strategies for multi-modal whole-body MRI mosaicing
    Ceranka, Jakub
    Polfliet, Mathias
    Lecouvet, Frederic
    Michoux, Nicolas
    de Mey, Johan
    Vandemeulebroucke, Jef
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1684 - 1695
  • [7] MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES
    DICE, LR
    [J]. ECOLOGY, 1945, 26 (03) : 297 - 302
  • [8] Inter-station intensity standardization for whole-body MR data
    Dzyubachyk, Oleh
    Staring, Marius
    Reijnierse, Monique
    Lelieveldt, Boudewijn P. F.
    van der Geest, Rob J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 422 - 433
  • [9] Analysis of intensity normalization for optimal segmentation performance of a fully convolutional neural network
    Jacobsen, Nina
    Deistung, Andreas
    Timmann, Dagmar
    Goericke, Sophia L.
    Reichenbachl, Juergen R.
    Guellmar, Daniel
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (02): : 128 - 138
  • [10] Nonrigid Registration of Joint Histograms for Intensity Standardization in Magnetic Resonance Imaging
    Jaeger, Florian
    Hornegger, Joachim
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (01) : 137 - 150