Development of personal comfort model and its use in the control of air conditioner

被引:19
|
作者
Wu, Yeyu [1 ,2 ]
Cao, Bin [1 ,2 ]
Hu, Minzhi [3 ]
Lv, Gengui [3 ]
Meng, Jianjun [4 ]
Zhang, Heng [4 ]
机构
[1] Tsinghua Univ, Sch Architecture, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Key Lab Eco Planning & Green Bldg, Minist Educ, Beijing 100084, Peoples R China
[3] Hisense Home Appliances Grp Co Ltd, Foshan, Guangdong, Peoples R China
[4] Qingdao Hisense Hitachi Air Conditioning Syst Co L, Qingdao, Shandong, Peoples R China
关键词
Thermal comfort; Infrared sensor; Skin temperature; Air conditioner control; Machine learning; THERMAL COMFORT; ENVIRONMENT; BEHAVIOR; PMV;
D O I
10.1016/j.enbuild.2023.112900
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The accurate identification of the real-time thermal state of personnel working indoors has been the focus of researchers. In this study, a detailed examination of the entire process of developing a personal comfort model, from theory to practice, is conducted. In particular, the subject of this investigation is a smart air conditioner capable of predicting thermal sensation based on an infrared (IR) sensor that measures the skin temperature of personnel and then implements automatic control. Random forest algorithm was employed to establish a thermal sensation prediction model, which accepts skin and air temperatures as input parameters. The model achieves a high prediction accuracy value of 0.84. Given the measure-ment errors of low-cost IR sensors, a simulated temperature measurement experiment based on the man-ikin was conducted, and an error calibration method based on multiple linear regression was developed through the experiment. 30 subjects participated in another prototype test experiment, which proved that the air conditioner can accomplish effective automatic control based on the prediction of thermal sensation, avoid the occurrence of extreme temperatures, and ensure the thermal comfort of personnel. The possible causes of remaining problems and potential improvement schemes are discussed in detail.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Development of an air conditioner for computer rooms
    Song, Liangyong
    Nuantong Kongtiao/HV & AC, 2000, 30 (03):
  • [22] Investigation of thermal comfort of room air conditioner during heating season
    Yang, Zixu
    Dong, Xian
    Xiao, Hansong
    Sun, Hongli
    Wang, Baolong
    Shi, Wenxing
    Li, Xianting
    BUILDING AND ENVIRONMENT, 2022, 207
  • [23] Development of heat exchanger for air conditioner
    Nakamura, Y
    Koido, T
    Hongo, I
    Nagamori, A
    COMPACT HEAT EXCHANGERS FOR THE PROCESS INDUSTRIES, 1997, : 475 - 482
  • [24] Air conditioner consumption optimization in an office building considering user comfort
    Khorram, Mahsa
    Faria, Pedro
    Abrishambaf, Omid
    Vale, Zita
    ENERGY REPORTS, 2020, 6 : 120 - 126
  • [25] Numerical experiment of thermal comfort in a bedroom equipped with air-conditioner
    Sin, VK
    Sun, HI
    Tam, LM
    Wong, KI
    COMPUTATIONAL METHODS IN ENGINEERING AND SCIENCE, PROCEEDINGS, 2003, : 787 - +
  • [26] Evaluation of Explicit Model Predictive Temperature Control for On-off Air Conditioner
    Chesof, Abdulhafiz
    Boksuwan, Sungwan
    Panaudomsup, Sumit
    Cheypoca, Thepjit
    2017 17TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2017, : 621 - 624
  • [27] Controller Design for Air Conditioner of a Vehicle with Three Control Inputs Using Model Predictive Control
    Parent, Trevor
    Defoe, Jeffrey J.
    Rahimi, Afshin
    MODELLING, 2024, 5 (01): : 117 - 152
  • [28] ROOM AIR-CONDITIONER FOR TROPICAL USE
    WATANABE, O
    TAJIMA, M
    NIGO, T
    TOSHIBA REVIEW, 1979, (119): : 31 - 34
  • [29] Building to Act as Its Own Air Conditioner
    不详
    ASHRAE JOURNAL, 2015, 57 (12) : 8 - 8
  • [30] CUSTOM AIR-CONDITIONER FOR STORE USE
    TANAKA, T
    MORI, M
    SUGIURA, H
    TOSHIBA REVIEW, 1979, (121): : 41 - 48