A Meta-Analysis and Systematic Review of Normothermic and Hypothermic Machine Perfusion in Liver Transplantation

被引:11
作者
Mugaanyi, Joseph [1 ,2 ]
Dai, Lei [1 ]
Lu, Changjiang [1 ]
Mao, Shuqi [1 ]
Huang, Jing [1 ]
Lu, Caide [1 ]
机构
[1] Ningbo Univ, Ningbo Med Ctr, Dept Hepatopancreato Biliary Surg, Affiliated Hosp,Li Huili Hosp, Ningbo 315040, Peoples R China
[2] Ningbo Univ, Sch Med, Ningbo 315211, Peoples R China
关键词
machine perfusion; normothermic; hypothermic; liver transplant; survival; EXTENDED-CRITERIA DONORS; STATIC COLD-STORAGE; OXYGENATED PERFUSION; RISK-FACTORS; PRESERVATION; DONATION; SURVIVAL; OUTCOMES; QUALITY; IMPACT;
D O I
10.3390/jcm12010235
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The gap between the demand and supply of donor livers is still a considerable challenge. Since static cold storage is not sufficient in marginal livers, machine perfusion is being explored as an alternative. The objective of this study was to assess (dual) hypothermic oxygenated machine perfusion (HOPE/D-HOPE) and normothermic machine perfusion (NMP) in contrast to static cold storage (SCS). Methods: Three databases were searched to identify studies about machine perfusion. Graft and patient survival and postoperative complications were evaluated using the random effects model. Results: the incidence of biliary complications was lower in HOPE vs. SCS (OR: 0.59, 95% CI: 0.36-0.98, p = 0.04, I-2: 0%). There was no significant difference in biliary complications between NMP and SCS (OR: 0.76, 95% CI: 0.41-1.40, p = 0.38, I-2: 55%). Graft and patient survival were significantly better in HOPE than in SCS (HR: 0.40, 95% CI: 0.23-0.71, p = 0.002, I-2: 0%) and (pooled HR: 0.43, 95% CI: 0.20-0.93, p = 0.03, I-2: 0%). Graft and patient survival were not significantly different between NMP and SCS. Conclusion: HOPE/D-HOPE and NMP are promising alternatives to SCS for donor liver preservation. They may help address the widening gap between the demand for and availability of donor livers by enabling the rescue and transplantation of marginal livers.
引用
收藏
页数:13
相关论文
共 43 条
[1]   Risk factors, surgical complications and graft survival in liver transplant recipients with early allograft dysfunction [J].
Bastos-Neves, Douglas ;
de Oliveira Salvalaggio, Paolo Rogerio ;
de Almeida, Marcio Dias .
HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2019, 18 (05) :423-429
[2]   Combined Hypothermic and Normothermic Machine Perfusion Improves Functional Recovery of Extended Criteria Donor Livers [J].
Boteon, Yuri L. ;
Laing, Richard W. ;
Schlegel, Andrea ;
Wallace, Lorraine ;
Smith, Amanda ;
Attard, Joseph ;
Bhogal, Ricky H. ;
Neil, Desley A. H. ;
Hubscher, Stefan ;
Perera, M. Thamara P. R. ;
Mirza, Darius F. ;
Afford, Simon C. ;
Mergental, Hynek .
LIVER TRANSPLANTATION, 2018, 24 (12) :1699-1715
[3]   Preliminary Single-Center Canadian Experience of Human Normothermic Ex Vivo Liver Perfusion: Results of a Clinical Trial [J].
Bral, M. ;
Gala-Lopez, B. ;
Bigam, D. ;
Kneteman, N. ;
Malcolm, A. ;
Livingstone, S. ;
Andres, A. ;
Emamaullee, J. ;
Russell, L. ;
Coussios, C. ;
West, L. J. ;
Friend, P. J. ;
Shapiro, A. M. J. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2017, 17 (04) :1071-1080
[4]   Subnormothermic Machine Perfusion for Ex Vivo Preservation and Recovery of the Human Liver for Transplantation [J].
Bruinsma, B. G. ;
Yeh, H. ;
Oezer, S. ;
Martins, P. N. ;
Farmer, A. ;
Wu, W. ;
Saeidi, N. ;
Op den Dries, S. ;
Berendsen, T. A. ;
Smith, R. N. ;
Markmann, J. F. ;
Porte, R. J. ;
Yarmush, M. L. ;
Uygun, K. ;
Izamis, M. -L. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 (06) :1400-1409
[5]   Determination and extension of the limits to static cold storage using subnormothermic machine perfusion [J].
Bruinsma, Bote G. ;
Berendsen, Tim A. ;
Izamis, Maria-Louisa ;
Yarmush, Martin L. ;
Uygun, Korkut .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2013, 36 (11) :775-780
[6]   Opposite acute potassium and sodium shifts during transplantation of hypothermic machine perfused donor livers [J].
Burlage, Laura C. ;
Hessels, Lara ;
van Rijn, Rianne ;
Matton, Alix P. M. ;
Fujiyoshi, Masato ;
van den Berg, Aad P. ;
Reyntjens, Koen M. E. M. ;
Meyer, Peter ;
de Boer, Marieke T. ;
de Kleine, Ruben H. J. ;
Nijsten, Maarten W. ;
Porte, Robert J. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2019, 19 (04) :1061-1071
[7]   Outcomes of transplantation of livers in from donation after circulatory death donors in the UK: a cohort study [J].
Callaghan, Christopher J. ;
Charman, Susan C. ;
Muiesan, Paolo ;
Powell, James J. ;
Gimson, Alexander E. ;
van der Meulen, Jan H. P. .
BMJ OPEN, 2013, 3 (09)
[8]   Machine perfusion for liver transplantation in the era of marginal organs-New kids on the block [J].
Czigany, Zoltan ;
Lurje, Isabella ;
Tolba, Rene H. ;
Neumann, Ulf P. ;
Tacke, Frank ;
Lurje, Georg .
LIVER INTERNATIONAL, 2019, 39 (02) :228-249
[9]   How to Preserve Liver Grafts From Circulatory Death With Long Warm Ischemia? A Retrospective Italian Cohort Study With Normothermic Regional Perfusion and Hypothermic Oxygenated Perfusion [J].
De Carlis, Riccardo ;
Schlegel, Andrea ;
Frassoni, Samuele ;
Olivieri, Tiziana ;
Ravaioli, Matteo ;
Camagni, Stefania ;
Patrono, Damiano ;
Bassi, Domenico ;
Pagano, Duilio ;
Di Sandro, Stefano ;
Lauterio, Andrea ;
Bagnardi, Vincenzo ;
Gruttadauria, Salvatore ;
Cillo, Umberto ;
Romagnoli, Renato ;
Colledan, Michele ;
Cescon, Matteo ;
Di Benedetto, Fabrizio ;
Muiesan, Paolo ;
De Carlis, Luciano .
TRANSPLANTATION, 2021, 105 (11) :2385-2396
[10]   Post-transplant cholangiopathy: Classification, pathogenesis, and preventive strategies [J].
de Vries, Yvonne ;
von Meijenfeldt, Fien A. ;
Porte, Robert J. .
BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR BASIS OF DISEASE, 2018, 1864 (04) :1507-1515