摘要
The study of the strength and failure modes of construction components has become increasingly important with the advent of industrialized construction. Recently, because of the need to promote the survivability of both structures and persons, it has encompassed failure modes associated with seismic threats. This study reports the seismic behavior of precast segmented columns designed with both unbonded prestressed tendons (UPTs) and energy-dissipating (ED) bars. A physical specimen was subjected to a quasi-static cyclic test; this permitted the evaluation of the damage mode and behavior of the energy dissipation mechanism, and permitted the establishment and verification of a fiber beam element simulation model. The model was then used to evaluate the effects of the variation of the design parameters on the behavior of precast assembled columns. The test specimen exhibited stable energy dissipation and a pinching effect during cyclic loading. An analysis using the fiber beam element model with varying design parameters revealed that high-strength concrete could mitigate the concrete damage and residual deformation after an earthquake, and that the concrete strength and steel bar strength should be matched when enhancing the seismic resilience of precast columns with high-strength steel bars. It was determined that increasing the prestress mechanism, namely the ratio of the UPTs, could greatly improve the residual deformation, while the ratio of ED bars is the key factor in enhancing the energy dissipation capacity of the precast columns. Suitable ratios of UPTs and ED bars are the keys to ensuring stable energy dissipation and low residual drifts. Moreover, an increased axial load ratio and prestress level are able to restrain the joint opening and improve the bearing capacity of the precast columns; however, an excessive axial load or prestressing force would result in the rapid degeneration of the carrying capacity and larger residual displacements.
引用
收藏
页数:15
相关论文
共 20 条
  • [1] Cyclic Loading Test of Unbonded and Bonded Posttensioned Precast Segmental Bridge Columns with Circular Section
    Bu, Zhan-Yu
    Ou, Yu-Chen
    Song, Jian-Wei
    Zhang, Na-Si
    Lee, George C.
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (02)
  • [2] Experimental testing and modeling of precast segmental bridge columns with hybrid normal- and high-strength steel rebars
    Cai, Zhong-Kui
    Wang, Zhenyu
    Yang, T. Y.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2018, 166 : 945 - 955
  • [3] Cheok GS, 1998, ACI STRUCT J, V95, P527
  • [4] [葛继平 Ge Jiping], 2011, [工程力学, Engineering Mechanics], V28, P122
  • [5] Structural performance evaluation of circular steel bands for PC column-beam connection
    Kim, Jeom Han
    Cho, Young Sang
    Lee, Kyung Hun
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2013, 65 (23) : 1377 - 1384
  • [6] Liu X., 2019, Eng. Struct, DOI [10.1016/j.109913, DOI 10.1016/J.109913]
  • [7] MTPRC (Ministry of Transport of the Peoples Republic of China), 2020, SPEC SEISM DES HIGHW
  • [8] Pseudodynamic Testing and Inelastic Displacement Ratios of Self-Centering Precast Concrete Segmental Bridge Columns
    Ou, Yu-Chen
    Pratiwi, Ade Yuniati
    Song, Jianwei
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (09)
  • [9] Large-Scale Experimental Study of Precast Segmental Unbonded Posttensioned Concrete Bridge Columns for Seismic Regions
    Ou, Yu-Chen
    Wang, Ping-Hsiung
    Tsai, Mu-Sen
    Chang, Kuo-Chun
    Lee, George C.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (03): : 255 - 264
  • [10] Design, modeling, and experimental response of seismic resistant bridge piers with posttensioned dissipating connections
    Palermo, A.
    Pampanin, S.
    Marriott, D.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2007, 133 (11) : 1648 - 1661