3D-assembled microneedle ion sensor-based wearable system for the transdermal monitoring of physiological ion fluctuations

被引:33
作者
Huang, Xinshuo [1 ]
Zheng, Shantao [1 ]
Liang, Baoming [1 ]
He, Mengyi [1 ]
Wu, Feifei [1 ,2 ]
Yang, Jingbo [3 ]
Chen, Hui-jiuan [1 ]
Xie, Xi [1 ,3 ]
机构
[1] Sun Yat Sen Univ, Sch Elect & Informat Technol, State Key Lab Optoelect Mat & Technol, Guangdong Prov Key Lab Display Mat & Technol, Guangzhou, Peoples R China
[2] Pazhou Lab, Guangzhou 510330, Peoples R China
[3] Sun Yat Sen Univ, Sch Biomed Engn, Guangzhou, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
GLUCOSE; ARRAY; BIOSENSOR;
D O I
10.1038/s41378-023-00497-0
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Monitoring human health is of considerable significance in biomedicine. In particular, the ion concentrations in blood are important reference indicators related to many diseases. Microneedle array-based sensors have enabled promising breakthroughs in continuous health monitoring due to their minimally invasive nature. In this study, we developed a microneedle sensing-array integrated system to continuously detect subcutaneous ions to monitor human health status in real time based on a fabrication strategy for assembling planar microneedle sheets to form 3D microneedle arrays. The limitations of preparing 3D microneedle structures with multiple electrode channels were addressed by assembling planar microneedle sheets fabricated via laser micromachining; the challenges of modifying closely spaced microneedle tips into different functionalized types of electrodes were avoided. The microneedle sensing system was sufficiently sensitive for detecting real-time changes in Ca2+, K+, and Na+ concentrations, and it exhibited good detection performance. The in vivo results showed that the ion-sensing microneedle array successfully monitored the fluctuations in Ca2+, K+, and Na+ in the interstitial fluids of rats in real time. By using an integrated circuit design, we constructed the proposed microneedle sensor into a wearable integrated monitoring system. The integrated system could potentially provide information feedback for diseases related to physiological ion changes.
引用
收藏
页数:16
相关论文
共 50 条
[1]  
Barrett-Connor E., 2018, Diabetes in America, V3rd
[2]   Minimally-invasive Microneedle-based Biosensor Array for Simultaneous Lactate and Glucose Monitoring in Artificial Interstitial Fluid [J].
Bollella, Paolo ;
Sharma, Sanjiv ;
Cass, Anthony Edward George ;
Antiochia, Riccarda .
ELECTROANALYSIS, 2019, 31 (02) :374-382
[3]   Advances in the Formulations of Microneedles for Manifold Biomedical Applications [J].
Chang, Hao ;
Zheng, Mengjia ;
Chew, Sharon Wan Ting ;
Xu, Chenjie .
ADVANCED MATERIALS TECHNOLOGIES, 2020, 5 (04)
[4]   Fabrication of Micro-Needle Electrodes for Bio-Signal Recording by a Magnetization-Induced Self-Assembly Method [J].
Chen, Keyun ;
Ren, Lei ;
Chen, Zhipeng ;
Pan, Chengfeng ;
Zhou, Wei ;
Jiang, Lelun .
SENSORS, 2016, 16 (09)
[5]   Nonenzymatic determination of glucose at near neutral pH values based on the use of nafion and platinum black coated microneedle electrode array [J].
Chinnadayyala, Somasekhar R. ;
Park, Ilhwan ;
Cho, Sungbo .
MICROCHIMICA ACTA, 2018, 185 (05)
[6]   Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring [J].
Dagdeviren, Canan ;
Su, Yewang ;
Joe, Pauline ;
Yona, Raissa ;
Liu, Yuhao ;
Kim, Yun-Soung ;
Huang, YongAn ;
Damadoran, Anoop R. ;
Xia, Jing ;
Martin, Lane W. ;
Huang, Yonggang ;
Rogers, John A. .
NATURE COMMUNICATIONS, 2014, 5
[7]   Microneedles-based electrochemical sensors: New tools for advanced biosensing [J].
Dardano, P. ;
Rea, I ;
De Stefano, L. .
CURRENT OPINION IN ELECTROCHEMISTRY, 2019, 17 :121-127
[8]   Smart Bandages: The Future of Wound Care [J].
Derakhshandeh, Hossein ;
Kashaf, Sara Saheb ;
Aghabaglou, Fariba ;
Ghanavati, Ian O. ;
Tamayol, Ali .
TRENDS IN BIOTECHNOLOGY, 2018, 36 (12) :1259-1274
[9]  
Egede LE, 2018, Diabetes in America
[10]   Simultaneous detection of glucose, uric acid and cholesterol using flexible microneedle electrode array-based biosensor and multi-channel portable electrochemical analyzer [J].
Gao, Jie ;
Huang, Wenzheng ;
Chen, Zhipeng ;
Yi, Changqing ;
Jiang, Lelun .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 287 :102-110