Investigation on Chloride-Induced Corrosion Reduction Strategies for Offshore Reinforced Concrete Structures

被引:0
作者
Tangtakabi, A. [1 ]
Ramesht, M. H. [1 ]
Pahlaviani, A. G. [1 ]
Pourrostam, T. [1 ]
机构
[1] Islamic Azad Univ, Fac Civil & Earth Resources Engn, Dept Civil Engn, Cent Tehran Branch, Tehran, Iran
关键词
Offshore concrete structure; Reinforcement corrosion; Durability; Chloride-induced corrosion; Corrosion measurement; SILICA FUME; MICRO SILICA; INHIBITOR; PERFORMANCE; DURABILITY; EFFICIENCY; INGRESS; SURFACE; GULF;
D O I
10.1007/s40996-023-01230-7
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The corrosion of reinforcement by chloride ions is a significant issue for reinforced concrete (RC) structures, which causes instability and loss of strength of the structure. In this study, the efficacy of various strategies for limiting the effects of chloride-induced corrosion on offshore RC structures was investigated experimentally through a series of experimental tests, including uniaxial compression test, half-cell potential test, and chloride ion penetration test. The tests have been conducted on concrete cube specimens with water/cement (w/c) ratios of 0.38, 0.45, and 0.50, which, for each w/c, the effect of normal cement (control specimens), engineered cementitious composite, self-compacting concrete (SCC), migration corrosion inhibitor (MCI), and microsilica (MS) were separately considered. The compressive strength of the specimens was obtained by uniaxial compression test at 7 and 28 days. Furthermore, to simulate wetting-drying cycles in marine environment, their corresponding 28 days cured specimens were exposed to the marine tidal zone at Technology and Durability Research Centre of Amir Kabir University, located at Bandar-e-Imam Khomeini, Iran, for 16 months and then were tested by half-cell potential and chloride ion penetration tests. The results revealed that, among all the specimens, the specimens with MCI and SCC achieved the highest and lowest compressive strength. In addition, the quantity of chloride ions that penetrate to the specimens indicates a low-risk corrosion for the specimens with MS and MCI and high-risk corrosion for the specimens with SCC. Moreover, it was concluded that using MCI was the most successful strategy for preventing reinforcement corrosion in maritime concrete structures.
引用
收藏
页码:1245 / 1260
页数:16
相关论文
共 30 条
  • [1] Residual capacity assessment of post-damaged RC columns exposed to high strain rate loading
    Abedini, Masoud
    Zhang, Chunwei
    [J]. STEEL AND COMPOSITE STRUCTURES, 2022, 45 (03) : 389 - 408
  • [2] Performance Assessment of Concrete and Steel Material Models in LS-DYNA for Enhanced Numerical Simulation, A State of the Art Review
    Abedini, Masoud
    Zhang, Chunwei
    [J]. ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2021, 28 (04) : 2921 - 2942
  • [3] The importance of chloride content at the concrete surface in assessing the time to corrosion of steel in concrete structures
    Ann, K. Y.
    Ahn, J. H.
    Ryou, J. S.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (01) : 239 - 245
  • [4] ASTM, 2015, STANDARD TEST METHOD
  • [5] Effect of Silica Fume and Fly Ash Admixtures on the Corrosion Behavior of AISI 304 Embedded in Concrete Exposed in 3.5% NaCl Solution
    Baltazar-Zamora, Miguel Angel
    Bastidas, David M.
    Santiago-Hurtado, Griselda
    Mendoza-Rangel, Jose Manuel
    Gaona-Tiburcio, Citlalli
    Bastidas, Jose M.
    Almeraya-Calderon, Facundo
    [J]. MATERIALS, 2019, 12 (23)
  • [6] Berke N. S., 1992, Corrosion forms and control for infrastructure
  • [7] Broomfield JP, 2011, Uhlig's corrosion handbook, P633
  • [8] Binding of externally supplied chlorides in micro silica concrete under field exposure conditions
    Dousti, Ali
    Shekarchi, Mohammad
    Alizadeh, Rouhollah
    Taheri-Motlagh, Ali
    [J]. CEMENT & CONCRETE COMPOSITES, 2011, 33 (10) : 1071 - 1079
  • [9] Simultaneous effect of nano and micro silica on corrosion behaviour of reinforcement in concrete containing cement strength grade of C-525
    Eskandari-Naddaf, Hamid
    Ziaei-Nia, Ali
    [J]. 11TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2017, 2018, 22 : 399 - 405
  • [10] Combined effect of Polypropylene fibers and Silica Fume to improve the durability of concrete with natural Pozzolans blended cement
    Flores Medina, N.
    Barluenga, G.
    Hernandez-Olivares, F.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2015, 96 : 556 - 566