Applications of deep learning to reduce the need for iodinated contrast media for CT imaging: a systematic review

被引:14
作者
Azarfar, Ghazal [1 ,2 ]
Ko, Seok-Bum [2 ]
Adams, Scott J. [3 ]
Babyn, Paul S. [1 ]
机构
[1] Univ Saskatchewan, Dept Med Imaging, Saskatoon, SK, Canada
[2] Univ Saskatchewan, Dept Elect & Comp Engn, Saskatoon, SK, Canada
[3] Stanford Univ, Dept Radiol, Stanford, CA USA
关键词
Computed tomography; Iodinated contrast media reduction; Contrast enhancement; Deep learning; PEDIATRIC CT; RECONSTRUCTION;
D O I
10.1007/s11548-023-02862-w
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeThe usage of iodinated contrast media (ICM) can improve the sensitivity and specificity of computed tomography (CT) for many clinical indications. However, the adverse effects of ICM administration can include renal injury, life-threatening allergic-like reactions, and environmental contamination. Deep learning (DL) models can generate full-dose ICM CT images from non-contrast or low-dose ICM administration or generate non-contrast CT from full-dose ICM CT. Eliminating the need for both contrast-enhanced and non-enhanced imaging or reducing the amount of required contrast while maintaining diagnostic capability may reduce overall patient risk, improve efficiency and minimize costs. We reviewed the current capabilities of DL to reduce the need for contrast administration in CT.MethodsWe conducted a systematic review of articles utilizing DL to reduce the amount of ICM required in CT, searching MEDLINE, Embase, Compendex, Inspec, and Scopus to identify papers published from 2016 to 2022. We classified the articles based on the DL model and ICM reduction.ResultsEighteen papers met the inclusion criteria for analysis. Of these, ten generated synthetic full-dose (100%) ICM from real non-contrast CT, while four augmented low-dose to full-dose ICM CT. Three used DL to create synthetic non-contrast CT from real 100% ICM CT, while one paper used DL to translate the 100% ICM to non-contrast CT and vice versa. DL models commonly used generative adversarial networks trained and tested by paired contrast-enhanced and non-contrast or low ICM CTs. Image quality metrics such as peak signal-to-noise ratio and structural similarity index were frequently used for comparing synthetic versus real CT image quality.ConclusionDL-generated contrast-enhanced or non-contrast CT may assist in diagnosis and radiation therapy planning; however, further work to optimize protocols to reduce or eliminate ICM for specific pathology is still needed along with a dedicated assessment of the clinical utility of these synthetic images.
引用
收藏
页码:1903 / 1914
页数:12
相关论文
共 41 条
[1]   Biases in electronic health record data due to processes within the healthcare system: retrospective observational study [J].
Agniel, Denis ;
Kohane, Isaac S. ;
Weber, Griffin M. .
BMJ-BRITISH MEDICAL JOURNAL, 2018, 361
[2]   Allergic-type reactions to radiographic contrast media [J].
Baerlocher, Mark O. ;
Asch, Murray ;
Myers, Andy .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2010, 182 (12) :1328-1328
[3]   Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner [J].
Benz, Dominik C. ;
Grani, Christoph ;
Moch, Beatrice Hirt ;
Mikulicic, Fran ;
Vontobel, Jan ;
Fuchs, Tobias A. ;
Stehli, Julia ;
Clerc, Olivier F. ;
Possner, Mathias ;
Pazhenkottil, Aju P. ;
Gaemperli, Oliver ;
Buechel, Ronny R. ;
Kaufmann, Philipp A. .
ACADEMIC RADIOLOGY, 2016, 23 (08) :1008-1014
[4]   Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation [J].
Brady, Samuel L. ;
Kaufman, Robert A. .
RADIOLOGY, 2012, 265 (03) :832-840
[5]   Practice Patterns for the Use of Iodinated IV Contrast Media for Pediatric CT Studies: A Survey of the Society for Pediatric Radiology [J].
Callahan, Michael J. ;
Servaes, Sabah ;
Lee, Edward Y. ;
Towbin, Alexander J. ;
Westra, Sjirk J. ;
Frush, Donald P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) :872-879
[6]   Practice Management Strategies for Imaging Facilities Facing an Acute Iodinated Contrast Media Shortage [J].
Cavallo, Joseph J. ;
Pahade, Jay K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (04) :666-670
[7]  
Chandrashekar A, 2020, EUR HEART J, V41, P156
[8]   A Deep Learning Approach to Visualize Aortic Aneurysm Morphology Without the Use of Intravenous Contrast Agents [J].
Chandrashekar, Anirudh ;
Handa, Ashok ;
Lapolla, Pierfrancesco ;
Shivakumar, Natesh ;
Uberoi, Raman ;
Grau, Vicente ;
Lee, Regent .
ANNALS OF SURGERY, 2023, 277 (02) :E449-E459
[9]   A review of medical image data augmentation techniques for deep learning applications [J].
Chlap, Phillip ;
Min, Hang ;
Vandenberg, Nym ;
Dowling, Jason ;
Holloway, Lois ;
Haworth, Annette .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2021, 65 (05) :545-563
[10]   Generating synthetic contrast enhancement from non-contrast chest computed tomography using a generative adversarial network [J].
Choi, Jae Won ;
Cho, Yeon Jin ;
Ha, Ji Young ;
Lee, Seul Bi ;
Lee, Seunghyun ;
Choi, Young Hun ;
Cheon, Jung-Eun ;
Kim, Woo Sun .
SCIENTIFIC REPORTS, 2021, 11 (01)