Turbulent thermal-hydraulic characteristics in a spiral corrugated waste heat recovery heat exchanger with perforated multiple twisted tapes

被引:25
|
作者
Hong, Yuxiang [1 ,3 ]
Zhao, Lei [1 ]
Huang, Yongchun [1 ]
Li, Qing [2 ]
Jiang, Jiajie [2 ]
Du, Juan [1 ]
机构
[1] Guangxi Univ Sci & Technol, Sch Biol & Chem Engn, Liuzhou 545006, Peoples R China
[2] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
[3] Lishui Univ, Dept Chem & Chem Engn, Lishui 323000, Peoples R China
基金
中国国家自然科学基金;
关键词
Waste heat recovery; Twisted tape; Spiral corrugated tube; Heat transfer enhancement; Fluid flow; TRANSFER ENHANCEMENT; FLUID-FLOW; CIRCULAR TUBE; PERFORMANCE ASSESSMENT; ENTROPY GENERATION; PRESSURE-DROP; LAMINAR-FLOW; PLAIN TUBE; V-CUT; NANOFLUID;
D O I
10.1016/j.ijthermalsci.2022.108025
中图分类号
O414.1 [热力学];
学科分类号
摘要
Waste heat recovery technology can undoubtedly improve energy saving and reduce carbon emissions, as one of the key equipment, heat exchangers always determine the waste heat recovery efficiency. In this study, to improve the heat transfer potentiality of conventional plain tube heat exchangers, a synergistic thermal enhancement technology of a spiral corrugated tube (SCT) with multiple twisted tapes (TTs) was devised by taking liquid-gas heat exchanging as a typical waste heat recovery scenario. The impacts of the TTs numbers, transverse space ratios (S/D), and longitudinal perforation length ratios (L/D) on tubular turbulent heat transfer -fluid flow characteristics were numerically investigated, consisting of flow fields, temperature contours, local Nusselt number (Nu) distributions, vortex structures, and turbulent kinetic energy contours, as well as average Nu, friction factor (f), and overall thermal performance evaluation index (ri). The findings proved that the fitting of multiple TTs into the SCT greatly homogenized the flow fields and temperature distributions, and increased the Nu and f, in which both of them also raised with the increase of the number of TTs. The ri dropped and subsequently augmented as the quantity of TTs increased. Furthermore, perforations on the surface of the quadruple TTs could attenuate the f with a relative less reduction in the Nu, which caused higher ri values than the ones without perforations. Notably, as demonstrated by the vortex structures, this could be ascribed to the fact that the perforations reduced excessive longitudinal vortex interactions in the mainstream regime without reducing the impingement to the thermal boundary layer too much. Both the Nu and f generally declined with rising S/D and L/D. Overall, by means of simple mounting perforations on the surface of the quadruple TTs, the maximum ri could be further enhanced up to around 7.9% and a maximum ri of 1.23 was obtained by the SCT with S/D = 0.152 and L/D = 0.348.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Effect of perforated twisted-tapes with parallel wings on heat transfer enhancement in a heat exchanger tube
    Thianpong, C.
    Eiamsa-ard, P.
    Promvonge, P.
    Eiamsa-ard, S.
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 1117 - 1123
  • [22] A comprehensive analysis of heat transfer in a heat exchanger with simple and perforated twisted tapes based on numerical simulations
    Sedaghat, Rezvan
    Dalili, Kimia Mobarhan
    Hosseinalipour, Seyed Mostafa
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 56
  • [23] Influence of perforated triple twisted tape on thermal performance characteristics of a tube heat exchanger
    Bhuiya, Muhammad Mostafa Kamal
    Roshid, Md Mamunur
    Talukder, Md Mehdi Masud
    Rasul, Mohammad Golam
    Das, Prasanjit
    APPLIED THERMAL ENGINEERING, 2020, 167
  • [24] Heat transfer and fluid flow characteristics of heat exchanger tube with multiple twisted tapes and solid rings inserts
    Singh, Vijaypal
    Chamoli, Sunil
    Kumar, Manoj
    Kumar, Alok
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 102 : 156 - 168
  • [25] Intensification of thermo-hydraulic performance in heat exchanger tube inserted with multiple twisted-tapes
    Piriyarungrod, N.
    Kumar, Manoj
    Thianpong, C.
    Pimsarn, M.
    Chuwattanakul, V
    Eiamsa-ard, S.
    APPLIED THERMAL ENGINEERING, 2018, 136 : 516 - 530
  • [26] Thermal-hydraulic performance analysis of printed circuit heat exchanger precooler in the Brayton cycle for supercritical CO2 waste heat recovery
    Liu, Bohan
    Lu, Mingjian
    Shui, Bo
    Sun, Yuwei
    Wei, Wei
    APPLIED ENERGY, 2022, 305
  • [27] Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
    Mashoofi, Nemat
    Pourahmad, Saman
    Pesteei, S. M.
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 161 - 168
  • [28] Impact of new multiple twisted tapes on treatment of solar heat exchanger
    M. Sheikholeslami
    Seyyed Ali Farshad
    M. Barzegar Gerdroodbary
    Amir H. Alavi
    The European Physical Journal Plus, 137
  • [29] Impact of new multiple twisted tapes on treatment of solar heat exchanger
    Sheikholeslami, M.
    Farshad, Seyyed Ali
    Gerdroodbary, M. Barzegar
    Alavi, Amir H.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2022, 137 (01):
  • [30] Thermal-hydraulic characteristics of microchannel heat exchanger and its application to solar gas turbines
    Utamura, Motoaki
    PROCEEDINGS OF THE ASME TURBO EXPO 2007, VOL 4, PTS A AND B, 2007, : 287 - 294