Turbulent thermal-hydraulic characteristics in a spiral corrugated waste heat recovery heat exchanger with perforated multiple twisted tapes

被引:27
作者
Hong, Yuxiang [1 ,3 ]
Zhao, Lei [1 ]
Huang, Yongchun [1 ]
Li, Qing [2 ]
Jiang, Jiajie [2 ]
Du, Juan [1 ]
机构
[1] Guangxi Univ Sci & Technol, Sch Biol & Chem Engn, Liuzhou 545006, Peoples R China
[2] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
[3] Lishui Univ, Dept Chem & Chem Engn, Lishui 323000, Peoples R China
基金
中国国家自然科学基金;
关键词
Waste heat recovery; Twisted tape; Spiral corrugated tube; Heat transfer enhancement; Fluid flow; TRANSFER ENHANCEMENT; FLUID-FLOW; CIRCULAR TUBE; PERFORMANCE ASSESSMENT; ENTROPY GENERATION; PRESSURE-DROP; LAMINAR-FLOW; PLAIN TUBE; V-CUT; NANOFLUID;
D O I
10.1016/j.ijthermalsci.2022.108025
中图分类号
O414.1 [热力学];
学科分类号
摘要
Waste heat recovery technology can undoubtedly improve energy saving and reduce carbon emissions, as one of the key equipment, heat exchangers always determine the waste heat recovery efficiency. In this study, to improve the heat transfer potentiality of conventional plain tube heat exchangers, a synergistic thermal enhancement technology of a spiral corrugated tube (SCT) with multiple twisted tapes (TTs) was devised by taking liquid-gas heat exchanging as a typical waste heat recovery scenario. The impacts of the TTs numbers, transverse space ratios (S/D), and longitudinal perforation length ratios (L/D) on tubular turbulent heat transfer -fluid flow characteristics were numerically investigated, consisting of flow fields, temperature contours, local Nusselt number (Nu) distributions, vortex structures, and turbulent kinetic energy contours, as well as average Nu, friction factor (f), and overall thermal performance evaluation index (ri). The findings proved that the fitting of multiple TTs into the SCT greatly homogenized the flow fields and temperature distributions, and increased the Nu and f, in which both of them also raised with the increase of the number of TTs. The ri dropped and subsequently augmented as the quantity of TTs increased. Furthermore, perforations on the surface of the quadruple TTs could attenuate the f with a relative less reduction in the Nu, which caused higher ri values than the ones without perforations. Notably, as demonstrated by the vortex structures, this could be ascribed to the fact that the perforations reduced excessive longitudinal vortex interactions in the mainstream regime without reducing the impingement to the thermal boundary layer too much. Both the Nu and f generally declined with rising S/D and L/D. Overall, by means of simple mounting perforations on the surface of the quadruple TTs, the maximum ri could be further enhanced up to around 7.9% and a maximum ri of 1.23 was obtained by the SCT with S/D = 0.152 and L/D = 0.348.
引用
收藏
页数:20
相关论文
共 69 条
  • [1] [Anonymous], 1986, J. Sci. Comput.
  • [2] Effect of various twisted-tape designs on the thermal and environmental performance of line-heaters in city gate stations
    Arabkoohsar, Ahmad
    Khosravi, Milad
    Alsagri, Ali Sulaiman
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [3] Short and spaced twisted tapes to mitigate fouling in tubular membranes
    Armbruster, Sarah
    Stockmeier, Felix
    Junker, Moritz
    Schiller-Becerra, Maira
    Yuece, Sueleyman
    Wessling, Matthias
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2020, 595 (595)
  • [4] Efficacy of a new graphene-platinum nanofluid in tubes fitted with single and twin twisted tapes regarding counter and co-swirling flows for efficient use of energy
    Bahiraei, Mehdi
    Mazaheri, Nima
    Hassanzamani, Seyed Mohammadhossein
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2019, 150 : 290 - 303
  • [5] Laminar flow heat transfer enhancement in a circular tube having integral transverse rib roughness and fitted with centre-cleared twisted-tape
    Bhattacharyya, Suvanjan
    Saha, Subhankar
    Saha, Sujoy Kumar
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 : 727 - 735
  • [6] Performance assessment in a heat exchanger tube fitted with double counter twisted tape inserts
    Bhuiya, M. M. K.
    Sayem, A. S. M.
    Islam, M.
    Chowdhury, M. S. U.
    Shahabuddin, M.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2014, 50 : 25 - 33
  • [7] Thermal characteristics in a heat exchanger tube fitted with triple twisted tape inserts
    Bhuiya, M. M. K.
    Chowdhury, M. S. U.
    Shahabuddin, M.
    Saha, M.
    Memon, L. A.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 48 : 124 - 132
  • [8] Influence of perforated triple twisted tape on thermal performance characteristics of a tube heat exchanger
    Bhuiya, Muhammad Mostafa Kamal
    Roshid, Md Mamunur
    Talukder, Md Mehdi Masud
    Rasul, Mohammad Golam
    Das, Prasanjit
    [J]. APPLIED THERMAL ENGINEERING, 2020, 167
  • [9] Thermal performance of tubular heat exchanger with multiple twisted-tape inserts
    Chokphoemphun, Suriya
    Pimsarn, Monsak
    Thianpong, Chinaruk
    Promvonge, Pongjet
    [J]. CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2015, 23 (05) : 755 - 762
  • [10] Experimental investigation on heat transfer enhancement with twisted tape having various V-cut configurations
    Chu, Wen-Xiao
    Tsai, Ching-An
    Lee, Bing-Hung
    Cheng, Kai-Yueh
    Wang, Chi-Chuan
    [J]. APPLIED THERMAL ENGINEERING, 2020, 172