Spatiotemporal denoising of low-dose cardiac CT image sequences using RecycleGAN

被引:2
|
作者
Zhou, Shiwei [1 ]
Yang, Jinyu [2 ]
Konduri, Krishnateja [3 ]
Huang, Junzhou [2 ]
Yu, Lifeng [4 ]
Jin, Mingwu [1 ]
机构
[1] Univ Texas Arlington, Dept Phys, Arlington, TX 76019 USA
[2] Univ Texas Arlington, Dept Comp Sci & Engn, Arlington, TX USA
[3] Univ Texas Arlington, Dept Bioengn, Arlington, TX USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
基金
美国国家卫生研究院;
关键词
CycleGAN; RecycleGAN; denoising; multi-phase CT angiography (MP-CTA); COMPUTED-TOMOGRAPHY; CORONARY-ANGIOGRAPHY; QUALITY;
D O I
10.1088/2057-1976/acf223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electrocardiogram (ECG)-gated multi-phase computed tomography angiography (MP-CTA) is frequently used for diagnosis of coronary artery disease. Radiation dose may become a potential concern as the scan needs to cover a wide range of cardiac phases during a heart cycle. A common method to reduce radiation is to limit the full-dose acquisition to a predefined range of phases while reducing the radiation dose for the rest. Our goal in this study is to develop a spatiotemporal deep learning method to enhance the quality of low-dose CTA images at phases acquired at reduced radiation dose. Recently, we demonstrated that a deep learning method, Cycle-Consistent generative adversarial networks (CycleGAN), could effectively denoise low-dose CT images through spatial image translation without labeled image pairs in both low-dose and full-dose image domains. As CycleGAN does not utilize the temporal information in its denoising mechanism, we propose to use RecycleGAN, which could translate a series of images ordered in time from the low-dose domain to the full-dose domain through an additional recurrent network. To evaluate RecycleGAN, we use the XCAT phantom program, a highly realistic simulation tool based on real patient data, to generate MP-CTA image sequences for 18 patients (14 for training, 2 for validation and 2 for test). Our simulation results show that RecycleGAN can achieve better denoising performance than CycleGAN based on both visual inspection and quantitative metrics. We further demonstrate the superior denoising performance of RecycleGAN using clinical MP-CTA images from 50 patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Diffusion probabilistic priors for zero-shot low-dose CT image denoising
    Liu, Xuan
    Xie, Yaoqin
    Liu, Chenbin
    Cheng, Jun
    Diao, Songhui
    Tan, Shan
    Liang, Xiaokun
    MEDICAL PHYSICS, 2024,
  • [42] Degradation Adaption Local-to-Global Transformer for Low-Dose CT Image Denoising
    Wang, Huan
    Chi, Jianning
    Wu, Chengdong
    Yu, Xiaosheng
    Wu, Hao
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (04) : 1894 - 1909
  • [43] Real-World Low-Dose CT Image Denoising by Patch Similarity Purification
    Song, Zeya
    Xue, Liqi
    Xu, Jun
    Zhang, Baoping
    Jin, Chao
    Yang, Jian
    Zou, Changliang
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2025, 34 : 196 - 208
  • [44] Image Denoising for Low-Dose CT via Convolutional Dictionary Learning and Neural Network
    Yan, Rongbiao
    Liu, Yi
    Liu, Yuhang
    Wang, Lei
    Zhao, Rongge
    Bai, Yunjiao
    Gui, Zhiguo
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2023, 9 : 83 - 93
  • [45] Scale-Sensitive Generative Adversarial Network for Low-Dose CT Image Denoising
    Wang, Yanling
    Han, Zefang
    Zhang, Xiong
    Shangguan, Hong
    Zhang, Pengcheng
    Li, Jie
    Xiao, Ning
    IEEE ACCESS, 2024, 12 : 98693 - 98706
  • [46] Low-dose CT Denoising with Dilated Residual Network
    Gholizadeh-Ansari, Maryam
    Alirezaie, Javad
    Babyn, Paul
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5117 - 5120
  • [47] Transformer With Double Enhancement for Low-Dose CT Denoising
    Li, Haoran
    Yang, Xiaomin
    Yang, Sihan
    Wang, Daoyong
    Jeon, Gwanggil
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (10) : 4660 - 4671
  • [48] Decomposition iteration strategy for low-dose CT denoising
    Li, Zhiyuan
    Liu, Yi
    Zhang, Pengcheng
    Lu, Jing
    Gui, Zhiguo
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (03) : 493 - 512
  • [49] NO-REFERENCE DENOISING OF LOW-DOSE CT PROJECTIONS
    Zainulina, Elvira
    Chernyavskiy, Alexey
    Dylov, Dmitry, V
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 77 - 81
  • [50] LOW-DOSE CT DENOISING WITH CONVOLUTIONAL NEUELA NETWORK
    Chen, Hu
    Zhang, Yi
    Zhang, Weihua
    Liao, Peixi
    Li, Ke
    Zhou, Jiliu
    Wang, Ge
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 143 - 146