Spatiotemporal denoising of low-dose cardiac CT image sequences using RecycleGAN

被引:2
|
作者
Zhou, Shiwei [1 ]
Yang, Jinyu [2 ]
Konduri, Krishnateja [3 ]
Huang, Junzhou [2 ]
Yu, Lifeng [4 ]
Jin, Mingwu [1 ]
机构
[1] Univ Texas Arlington, Dept Phys, Arlington, TX 76019 USA
[2] Univ Texas Arlington, Dept Comp Sci & Engn, Arlington, TX USA
[3] Univ Texas Arlington, Dept Bioengn, Arlington, TX USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
基金
美国国家卫生研究院;
关键词
CycleGAN; RecycleGAN; denoising; multi-phase CT angiography (MP-CTA); COMPUTED-TOMOGRAPHY; CORONARY-ANGIOGRAPHY; QUALITY;
D O I
10.1088/2057-1976/acf223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Electrocardiogram (ECG)-gated multi-phase computed tomography angiography (MP-CTA) is frequently used for diagnosis of coronary artery disease. Radiation dose may become a potential concern as the scan needs to cover a wide range of cardiac phases during a heart cycle. A common method to reduce radiation is to limit the full-dose acquisition to a predefined range of phases while reducing the radiation dose for the rest. Our goal in this study is to develop a spatiotemporal deep learning method to enhance the quality of low-dose CTA images at phases acquired at reduced radiation dose. Recently, we demonstrated that a deep learning method, Cycle-Consistent generative adversarial networks (CycleGAN), could effectively denoise low-dose CT images through spatial image translation without labeled image pairs in both low-dose and full-dose image domains. As CycleGAN does not utilize the temporal information in its denoising mechanism, we propose to use RecycleGAN, which could translate a series of images ordered in time from the low-dose domain to the full-dose domain through an additional recurrent network. To evaluate RecycleGAN, we use the XCAT phantom program, a highly realistic simulation tool based on real patient data, to generate MP-CTA image sequences for 18 patients (14 for training, 2 for validation and 2 for test). Our simulation results show that RecycleGAN can achieve better denoising performance than CycleGAN based on both visual inspection and quantitative metrics. We further demonstrate the superior denoising performance of RecycleGAN using clinical MP-CTA images from 50 patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A Spatiotemporal Denoising Method for Low-Dose Cardiac CT Images
    Yang, J.
    Zhou, S.
    Huang, J.
    Yu, L.
    Jin, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Denoising on Low-Dose CT Image Using Deep CNN
    Sadamatsu, Yuta
    Murakami, Seiichi
    Li, Guangxu
    Kamiya, Tohru
    2022 22ND INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2022), 2022, : 546 - 549
  • [3] Low-Dose CT Denoising Using Pseudo-CT Image Pairs
    Won, Dongkyu
    Jung, Euijin
    An, Sion
    Chikontwe, Philip
    Park, Sang Hyun
    PREDICTIVE INTELLIGENCE IN MEDICINE, PRIME 2021, 2021, 12928 : 1 - 10
  • [4] Task-Oriented Low-Dose CT Image Denoising
    Zhang, Jiajin
    Chao, Hanqing
    Xu, Xuanang
    Niu, Chuang
    Wang, Ge
    Yan, Pingkun
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VI, 2021, 12906 : 441 - 450
  • [5] Low-Dose CT Image Denoising Using Cycle-Consistent Adversarial Networks
    Li, Zeheng
    Huang, Junzhou
    Yu, Lifeng
    Chi, Yujie
    Jin, Mingwu
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [6] Low-dose CT Image Denoising Using Classification Densely Connected Residual Network
    Ming, Jun
    Yi, Benshun
    Zhang, Yungang
    KSII TRANSACTIONS ON INTERNET AND INFORMATION SYSTEMS, 2020, 14 (06) : 2480 - 2496
  • [7] Investigation of Low-Dose CT Image Denoising Using Unpaired Deep Learning Methods
    Li, Zeheng
    Zhou, Shiwei
    Huang, Junzhou
    Yu, Lifeng
    Jin, Mingwu
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (02) : 224 - 234
  • [8] UNet with ResNextify and IB modules for low-dose CT image denoising
    Chauhan S.
    Malik N.
    Vig R.
    International Journal of Information Technology, 2024, 16 (7) : 4677 - 4692
  • [9] A multi-attention Uformer for low-dose CT image denoising
    Huimin Yan
    Chenyun Fang
    Zhiwei Qiao
    Signal, Image and Video Processing, 2024, 18 : 1429 - 1442
  • [10] Separation-based model for low-dose CT image denoising
    Chen, Wenbin
    Bai, Junjie
    Gu, Xiaohua
    Li, Yuyan
    Shao, Yanling
    Zhang, Quan
    Liu, Yi
    Liu, Yanli
    Gui, Zhiguo
    JOURNAL OF ENGINEERING-JOE, 2020, 2020 (12): : 1198 - 1208