Active Location Method for Single-Line-to-Ground Fault of Flexible Grounding Distribution Networks

被引:6
|
作者
Lin, Jiahao [1 ]
Guo, Moufa [1 ]
Zheng, Zeyin [1 ]
机构
[1] Fuzhou Univ, Coll Elect Engn & Automat, Fuzhou 350108, Peoples R China
基金
中国国家自然科学基金;
关键词
Index Terms-Fault arc suppression; fault section active location method; flexible grounding distribution network; ground fault nature judgment; single-line-to-ground (SLG) fault; SECTION IDENTIFICATION; DISTRIBUTION-SYSTEMS; PHASE;
D O I
10.1109/TIM.2023.3298416
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The single-line-to-ground (SLG) fault is the most common fault in distribution networks. The output current of cascaded H-bridges (CHBs) can be controlled flexibly to suppress SLG fault current. Therefore, a CHB-based active location method is proposed in this article, which integrates the functions of SLG fault arc suppression, fault section location, and fault nature judgment. When an SLG fault occurs, CHB devices quickly inject full compensated current into the system neutral to suppress the fault current. Then, CHB devices are regulated to reduce the injected current, and the variations of zero-sequence voltage and zero-sequence current are actively constructed. The phase characteristics between zero-sequence voltage variation and zero-sequence current variation can be used as the criteria for fault section location and fault nature judgment. In addition, the measurement device, namely, the retrofitted feeder terminal unit (FTU), contains signal acquisition module, and signal calculation module is designed, which can collect the zero-sequence signal and calculate the phase difference. Finally, the effectiveness of these three functions and the fault-location accuracy of the proposed method have been verified through the simulation and experimental cases.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Fault section location method for single-phase grounding fault in distribution network based on ESMD
    Yin Z.
    Sun G.
    Ding J.
    Lü F.
    Yuan H.
    Wei Z.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (06): : 173 - 178and191
  • [42] Line selection method for grounding fault in resonant grounding distribution systems
    Long R.
    Huang C.
    Tang T.
    Zeng J.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (21): : 21 - 29
  • [43] A novel one-terminal single-line-to-ground fault location algorithm in transmission line using post-single-phase-trip data
    Geng, Jianzhao
    Wang, Bin
    Dong, Xinzhou
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (16): : 184 - 193
  • [44] State Estimation Based Fault Location Method for Active Distribution Networks
    Wang, Binglin
    Liu, Yu
    Zhao, Junbo
    Jia, Yixiong
    Chen, Xinyu
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [45] Fault Location Method for Active Distribution Networks Considering Combination Faults
    Zhang J.
    Gao Z.
    Chen M.
    Wei Z.
    An S.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (11): : 2265 - 2276
  • [46] Fault Location of Active Distribution Networks Based on the Golden Section Method
    Yang, Haizhu
    Liu, Xiangyang
    Guo, Yiming
    Zhang, Peng
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [47] Fault Location Method of Flexible DC Distribution Network Based on Active Control of Fault Current
    Mei J.
    Zhang B.
    Zhu P.
    Ge R.
    Yan L.
    Chen X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (24): : 133 - 141
  • [48] Active High-Impedance Fault Detection Method for Resonant Grounding Distribution Networks
    Yao, Zhiwei
    Liu, Yang
    Chen, Jian
    Ji, Jinpeng
    Zhang, Mengdi
    Gong, Yanyong
    IEEE ACCESS, 2024, 12 : 10932 - 10945
  • [49] SINGLE-LINE-TO-GROUND FAULT TEST OF A 3-PHASE SUPERCONDUCTING FAULT CURRENT LIMITING REACTOR
    SHIMIZU, S
    KADO, H
    URIU, Y
    ISHIGOHKA, T
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (01) : 442 - 445
  • [50] The Identification of Single-Line-to-Ground Fault in Neutral Un-effectively Earthed System
    Dong, Fengxiang
    Tang, Chaoguo
    Yuan, Zheng
    Zhang, Wenhai
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 673 - +