Trends in Total Knee Arthroplasty Cementing Technique Among Arthroplasty Surgeons-A Survey of the American Association of Hip and Knee Surgeons Members

被引:5
作者
Martin, J. Ryan [1 ]
Archibeck, Michael J. [2 ]
Gililland, Jeremy M. [2 ]
Anderson, Lucas A. [2 ]
Polkowski, Gregory G. [1 ]
Schwarzkopf, Ran [3 ]
Seyler, Thorsten M. [4 ]
Pelt, Christopher E. [2 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Orthopaed Surg, Nashville, TN USA
[2] Univ Utah, Dept Orthopaed Surg, 590 Wakara Way, Salt Lake City, UT 84018 USA
[3] NYU Langone Hlth, Dept Orthoped Surg, New York, NY USA
[4] Duke Univ, Med Ctr, Sch Med, Durham, NC 27710 USA
关键词
total knee arthroplasty; cement technique; AAHKS; survey; cemented knee replacement; TIBIAL COMPONENT; INTERFACE; TOURNIQUET; STRENGTH;
D O I
10.1016/j.arth.2022.12.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Aseptic loosening persists as one of the leading causes of failure following cemented primary total knee arthroplasty (TKA). Cement technique may impact implant fixation. We hypothesized that there is variability in TKA cement technique among arthroplasty surgeons. Methods: A 28-question survey regarding variables in surgeons' preferred TKA cementation technique was distributed to 2,791 current American Association of Hip and Knee Surgeons (AAHKS) members with a response rate of 30.8% (903 respondents). Patterns of responses were analyzed by grouping respondents by their answers to certain questions including cementing technique, tibial cement location, and femoral cement location. Results: A total of 73.5% reported performing at least 7 of 8 of the highest consensus techniques, including vacuum mixing (79.9%), using two bags (76.1%), tibial implant first (95.2%), single-stage cementing (96.9%), compression of the implants in extension (91.7%), and use of a tourniquet (84.3%). Medium and high viscosity cement was most commonly used (37.9 and 37.8%, respectively). Finger pressurization was most common (76.1%) compared to a gun (29.8%). There were 26.5% of respondents performing 6 or fewer of the most common majority techniques and seemed to perform other less common techniques (eg, use of a single bag of cement, trialing or closure prior to cement curing, and heating to accelerate cement curing). Cement was most commonly applied to the entire bone and implant surface on both the tibia (46.4%) and femur (47.7%), leaving much variation in the remaining cement application location responses. Discussion: There appears to be variability in cemented TKA technique among arthroplasty surgeons. There were 26.5% of respondents performing less of the majority techniques and also performed other additional low-response rate techniques. Further studies that look at the impacts of variation in techniques on outcomes may be warranted. Our study demonstrates the need for defining best practices for cement technique given the substantial variability identified. (c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:S233 / +
页数:12
相关论文
共 27 条
  • [1] Increased Aseptic Tibial Failures in Patients With a BMI ≥ 35 and Well-Aligned Total Knee Arthroplasties
    Abdel, Matthew P.
    Bonadurer, George F., III
    Jennings, Matthew T.
    Hanssen, Arlen D.
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (12) : 2181 - 2184
  • [2] Survey of AAHKS International Members on the Impact of COVID-19 on Hip and Knee Arthroplasty Practices
    Athey, Alexander G.
    Cao, Li
    Okazaki, Ken
    Zagra, Luigi
    Castelli, Claudio C.
    Kendoff, Daniel O.
    Kerr, Joshua M.
    Yates, Adolph J., Jr.
    Stambough, Jeffrey B.
    Sierra, Rafael J.
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (07) : S89 - S94
  • [3] Material tailoring of the femoral component in a total knee replacement to reduce the problem of aseptic loosening
    Bahraminasab, Marjan
    Sahari, B. B.
    Edwards, K. L.
    Farahmand, Farzam
    Hong, Tang Sai
    Naghibi, Hamid
    [J]. MATERIALS & DESIGN, 2013, 52 : 441 - 451
  • [4] Bert JM, 1998, CLIN ORTHOP RELAT R, P73
  • [5] Techniques for improving the initial strength of the tibial tray-cement interface bond
    Billi, F.
    Kavanaugh, A.
    Schmalzried, H.
    Schmalzried, T. P.
    [J]. BONE & JOINT JOURNAL, 2019, 101B (01) : 53 - 58
  • [6] The Epidemiology of Revision Total Knee Arthroplasty in the United States
    Bozic, Kevin J.
    Kurtz, Steven M.
    Lau, Edmund
    Ong, Kevin
    Chiu, Vanessa
    Vail, Thomas P.
    Rubash, Harry E.
    Berry, Daniel J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 45 - 51
  • [7] Primary Total Knee Arthroplasty Performed Using High-Viscosity Cement is Associated With Higher Odds of Revision for Aseptic Loosening
    Buller, Leonard T.
    Rao, Vindhya
    Chiu, Yu-Fen
    Nam, Denis
    McLawhorn, Alexander S.
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (06) : S182 - S189
  • [8] Cementing techniques for the tibial component in primary total knee replacement
    Cawley, D. T.
    Kelly, N.
    McGarry, J. P.
    Shannon, F. J.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (03) : 295 - 300
  • [9] Full and surface tibial cementation in total knee arthroplasty: A biomechanical investigation of stress distribution and remodeling in the tibia
    Cawley, Derek T.
    Kelly, Nicola
    Simpkin, Andrew
    Shannon, Fintan J.
    McGarry, J. Patrick
    [J]. CLINICAL BIOMECHANICS, 2012, 27 (04) : 390 - 397
  • [10] Cementless versus cemented total knee arthroplasty in young patients: a meta-analysis of randomized controlled trials
    Chen, Chengyu
    Li, Ruodong
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)