Performance optimization of open refrigerated display cabinet based on response surface method

被引:10
作者
Li, Xueqiang [1 ]
Liu, Huan [1 ]
Zhang, Zhongyao [1 ]
Hu, Xiuzhen [2 ]
Liu, Shengchun [1 ,3 ]
Guo, Yonghui [1 ]
机构
[1] Tianjin Univ Commerce, Key Lab Refrigerat Technol Tianjin, Tianjin 300134, Peoples R China
[2] Qingdao Hiron Commercial Cold Chain Co Ltd, Qingdao 266000, Peoples R China
[3] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ener, Tianjin 300350, Peoples R China
关键词
Air curtain; Open refrigerated display cabinet; Response surface method; Multi-objective optimization; AIR CURTAINS; TEMPERATURE; ENTRAINMENT; SIMULATION; MODEL;
D O I
10.1016/j.applthermaleng.2022.119608
中图分类号
O414.1 [热力学];
学科分类号
摘要
The quality of air curtain is very important for the energy saving, which can be found in many scenarios, such as open refrigerated display cabinet (ORDC), refrigeration storage, mall, and restaurant. ORDC uses the air curtain as a barrier to reduce the mixing of cold and ambient air. During operation, the ORDC performance, including the quality of air curtain, can be affected by many factors. Therefore, the impact of seven parameters, including the structural parameter, operating parameter, and ambient parameter, is fully discussed by using the validated model and response surface method (RSM). The regression equations for each performance indicator are obtained, which can also be used to optimize the ORDC. Results showed not only the impact of single parameter, but also the interactive impact of multi-parameter should be carefully optimized. Compared the basic condition, the optimal parameter could decrease the thermal entrainment factor (TEF) by 44 %, the energy consumption by 8.4 %, and the temperature uniformity by 0.38 degrees C. The conclusion obtained in this paper could provide a guidance and optimization method when optimizing ORDC and other devices with air curtain.
引用
收藏
页数:13
相关论文
共 39 条
[11]   Entrainment of refrigerated air curtains down a wall [J].
Field, BS ;
Loth, E .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2006, 30 (03) :175-184
[12]  
Fricke B., 2010, Purdue e-pubs energy use of doored and open vertical refrigerated display cases Online
[13]   Multi-objective optimization of thermal performance of packed bed latent heat thermal storage system based on response surface method [J].
Gao, Long ;
Gegentana ;
Liu, Zhongze ;
Sun, Baizhong ;
Che, Deyong ;
Li, Shaohua .
RENEWABLE ENERGY, 2020, 153 :669-680
[14]  
Gaspar P.D., 2010, P ASME 2010 10 BIENN, DOI [10.1115/ESDA2010-24124, DOI 10.1115/ESDA2010-24124]
[15]   Experimental analysis of the thermal entrainment factor of air curtains in vertical open display cabinets for different ambient air conditions [J].
Gaspar, Pedro Dinis ;
Carrilho Goncalves, L. C. ;
Pitarma, R. A. .
APPLIED THERMAL ENGINEERING, 2011, 31 (05) :961-969
[16]   Performance simulation of refrigerated display cabinets operating with refrigerants R22 and R404A [J].
Ge, Y. T. ;
Cropper, R. .
APPLIED ENERGY, 2008, 85 (08) :694-707
[17]   Simulation of the performance of single jet air curtains for vertical refrigerated display cabinets [J].
Ge, YT ;
Tassou, SA .
APPLIED THERMAL ENGINEERING, 2001, 21 (02) :201-219
[18]   Development of a stability model for a vertical single band recirculated air curtain sealing a refrigerated cavity [J].
Hammond, Edward ;
Quarini, Joe ;
Foster, Alan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (06) :1455-1461
[19]   Temperature and energy performance of open refrigerated display cabinets using heat pipe shelves [J].
Jouhara, H. ;
Nannou, T. ;
Ghazal, H. ;
Kayyali, R. ;
Tassou, S. A. ;
Lester, S. .
PROCEEDINGS OF 1ST INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS (ICFES 2017), INCLUDING SYMPOSIUM ON HEAT RECOVERY AND EFFICIENT CONVERSION AND UTILISATION OF WASTE HEAT, 2017, 123 :273-280
[20]   Numerical investigation of cooling performance of a novel air-cooled thermal management system for cylindrical Li-ion battery module [J].
Kausthubharam ;
Koorata, Poornesh K. ;
Chandrasekaran, Neelakandan .
APPLIED THERMAL ENGINEERING, 2021, 193