Performance optimization of open refrigerated display cabinet based on response surface method

被引:10
作者
Li, Xueqiang [1 ]
Liu, Huan [1 ]
Zhang, Zhongyao [1 ]
Hu, Xiuzhen [2 ]
Liu, Shengchun [1 ,3 ]
Guo, Yonghui [1 ]
机构
[1] Tianjin Univ Commerce, Key Lab Refrigerat Technol Tianjin, Tianjin 300134, Peoples R China
[2] Qingdao Hiron Commercial Cold Chain Co Ltd, Qingdao 266000, Peoples R China
[3] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ener, Tianjin 300350, Peoples R China
关键词
Air curtain; Open refrigerated display cabinet; Response surface method; Multi-objective optimization; AIR CURTAINS; TEMPERATURE; ENTRAINMENT; SIMULATION; MODEL;
D O I
10.1016/j.applthermaleng.2022.119608
中图分类号
O414.1 [热力学];
学科分类号
摘要
The quality of air curtain is very important for the energy saving, which can be found in many scenarios, such as open refrigerated display cabinet (ORDC), refrigeration storage, mall, and restaurant. ORDC uses the air curtain as a barrier to reduce the mixing of cold and ambient air. During operation, the ORDC performance, including the quality of air curtain, can be affected by many factors. Therefore, the impact of seven parameters, including the structural parameter, operating parameter, and ambient parameter, is fully discussed by using the validated model and response surface method (RSM). The regression equations for each performance indicator are obtained, which can also be used to optimize the ORDC. Results showed not only the impact of single parameter, but also the interactive impact of multi-parameter should be carefully optimized. Compared the basic condition, the optimal parameter could decrease the thermal entrainment factor (TEF) by 44 %, the energy consumption by 8.4 %, and the temperature uniformity by 0.38 degrees C. The conclusion obtained in this paper could provide a guidance and optimization method when optimizing ORDC and other devices with air curtain.
引用
收藏
页数:13
相关论文
共 39 条
[1]  
11bz, GBT2100122015 NAT ST
[2]   The novel use of phase change materials in an open type refrigerated display cabinet: A theoretical investigation [J].
Alzuwaid, F. A. ;
Ge, Y. T. ;
Tassou, S. A. ;
Sun, J. .
APPLIED ENERGY, 2016, 180 :76-85
[3]   Less energy and material consumption in an electrocoagulation system using AC waveform instead of DC for nickel removal: Process optimization through RSM [J].
Arabameri, Amirreza ;
Moghaddam, Mohammad Reza Alavi ;
Azadmehr, Amir Reza ;
Shabestar, Mahsa Payami .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2022, 174
[4]   Analysis of energy savings in a supermarket refrigeration/HVAC system [J].
Bahman, Ammar ;
Rosario, Luis ;
Rahman, Muhammad M. .
APPLIED ENERGY, 2012, 98 :11-21
[5]   Numerical Simulation on the Food Package Temperature in Refrigerated Display Cabinet Influenced by Indoor Environment [J].
Chang Zhijuan ;
Wu Xuehong ;
Lu Yanli ;
Ma Qiuyang ;
Zhang Wenhui .
ADVANCES IN MECHANICAL ENGINEERING, 2013,
[6]   Experimental study of the performance of single-band air curtains for a multi-deck refrigerated display cabinet [J].
Chen, YG ;
Yuan, XL .
JOURNAL OF FOOD ENGINEERING, 2005, 69 (03) :261-267
[7]   Parametric evaluation of refrigerated air curtains for thermal insulation [J].
Chen, Yun-Guang .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (10) :1988-1996
[8]   Effects of an Air Curtain on the Temperature Distribution in Refrigerated Vehicles Under a Hot Climate Condition [J].
Cong, Lin ;
Yu, Qinghua ;
Qiao, Geng ;
Li, Yongliang ;
Ding, Yulong .
JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2019, 11 (06)
[9]   Life cycle techno-enviro-economic assessment of dual-temperature evaporation transcritical CO2 high-temperature heat pump systems for industrial waste heat recovery [J].
Dai, Baomin ;
Liu, Chen ;
Liu, Shengchun ;
Wang, Dabiao ;
Wang, Qilong ;
Zou, Tonghua ;
Zhou, Xuan .
APPLIED THERMAL ENGINEERING, 2023, 219
[10]   Optimal supply air temperature with respect to energy use in a variable air volume system [J].
Engdahl, F ;
Johansson, D .
ENERGY AND BUILDINGS, 2004, 36 (03) :205-218