A derivation of the electrical capacitance tomography sensitivity matrix

被引:12
作者
Youngquist, Robert C. [1 ]
Storey, Jedediah M. [2 ]
Nurge, Mark A. [1 ]
Biagi, Christopher J. [1 ]
机构
[1] NASA, Appl Phys Lab, Kennedy Space Ctr, Mail Code UB-G2, Merritt Isl, FL 32899 USA
[2] NASA, Environm & Launch Approval Branch, Kennedy Space Ctr, Mail Code VA-H3, Merritt Isl, FL 32899 USA
关键词
electrical capacitance tomography; sensitivity matrix; high-contrast permittivity; IMAGE-RECONSTRUCTION;
D O I
10.1088/1361-6501/aca0b1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The sensitivity matrix, used in electrical capacitance tomography to connect capacitance readings to a dielectric distribution, is derived without assumptions on the magnitude of the relative permittivity and without dropping higher order terms. Deriving this matrix may provide a means to improve the performance of the various published electrical capacitance tomography algorithms and extend their applicability to a wider range of dielectric materials.
引用
收藏
页数:8
相关论文
共 19 条
[1]   THREE-DIMENSIONAL NONLINEAR INVERSION OF ELECTRICAL CAPACITANCE TOMOGRAPHY DATA USING A COMPLETE SENSOR MODEL [J].
Banasiak, R. ;
Wajman, R. ;
Sankowski, D. ;
Soleimani, M. .
PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2010, 100 :219-234
[2]  
Behruzi P., 2020, P AIAA PROP EN FOR, P3804
[3]   Image reconstruction technique of electrical capacitance tomography for low-contrast dielectrics using Calderon's method [J].
Cao, Zhang ;
Xu, Lijun ;
Wang, Huaxiang .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (10)
[4]   Modal Propellant Gauging: High-resolution and non-invasive gauging of both settled and unsettled liquids in reduced gravity [J].
Crosby, Kevin M. ;
Williams, Nehemiah J. ;
Werlink, Rudolph J. ;
Hurlbert, Eric A. .
ACTA ASTRONAUTICA, 2019, 159 :499-507
[5]  
Dodge FT., 2008, E1657
[6]   Spectral mass gauging of unsettled liquid with acoustic waves [J].
Feller, Jeffrey ;
Kashani, Ali ;
Khasin, Michael ;
Muratov, Cyrill ;
Osipov, Viatcheslav ;
Sharma, Surendra .
ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
[7]   A machine learning approach for electrical capacitance tomography measurement of gas-solid fluidized beds [J].
Guo, Qiang ;
Ye, Mao ;
Yang, Wuqiang ;
Liu, Zhongmin .
AICHE JOURNAL, 2019, 65 (06)
[8]   Investigation of square fluidized beds using capacitance tomography: preliminary results [J].
Liu, S ;
Yang, WQ ;
Wang, H ;
Jiang, F ;
Su, Y .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (08) :1120-1125
[9]   Real-Time Implementation of Calderon's Method on Subject-Specific Domains [J].
Muller, Peter A. ;
Mueller, Jennifer L. ;
Mellenthin, Michelle M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) :1868-1875
[10]   Electrical capacitance volume tomography with high contrast dielectrics using a cuboid sensor geometry [J].
Nurge, Mark A. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (05) :1511-1520