Textured versus Smooth Tissue Expanders: A Comparison of Complications in 3526 Breast Reconstructions

被引:6
|
作者
Nelson, Jonas A. [1 ,3 ]
Rubenstein, Robyn N. [1 ]
Vorstenbosch, Joshua [2 ]
Haglich, Kathryn [1 ]
Poulton, Richard T. [1 ]
Mcgriff, De'von [1 ]
Stern, Carrie S. [1 ]
Coriddi, Michelle [1 ]
Cordeiro, Peter G. [1 ]
Mccarthy, Colleen M. [1 ]
Disa, Joseph J. [1 ]
Mehrara, Babak J. [1 ]
Matros, Evan [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Surg, Plast & Reconstruct Surg Serv, New York, NY USA
[2] McGill Univ, Royal Victoria Hosp, Dept Surg, Plast & Reconstruct Surg Serv, Montreal, PQ, Canada
[3] Mem Sloan Kettering Canc Ctr, Dept Surg, Plast & Reconstruct Surg Serv, 321 East 61st,6th Floor, New York, NY 10065 USA
关键词
IMPLANTS; EXPERIENCE; SURFACE;
D O I
10.1097/PRS.0000000000010600
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Increased understanding of breast implantassociated anaplastic large-cell lymphoma has led to a shift away from textured breast devices. A few small studies have compared the complication rates of textured and smooth tissue expanders (TEs). The aim of this study was to compare complication profiles in patients undergoing two-stage postmastectomy breast reconstruction with either textured or smooth TEs. Methods: The authors performed a retrospective review of female patients who underwent immediate breast reconstruction with textured or smooth TEs from 2018 to 2020 at their institution. Rates of seroma, infection/cellulitis, malposition/rotation, exposure, and TE loss were analyzed in the overall cohort and subgroups undergoing prepectoral and subpectoral TE placement. A propensity scorematched analysis was used to decrease the effects of confounders comparing textured and smooth TEs. Results: The authors analyzed 3526 TEs (1456 textured and 2070 smooth). More frequent use of acellular dermal matrix, SPY angiography, and prepectoral TE placement was noted in the smooth TE cohort (P < 0.001). Univariate analysis suggested higher rates of infection/cellulitis, malposition/rotation, and exposure in smooth TEs (all P < 0.01). Rates of TE loss did not differ. After propensity matching, no differences were noted in infection or TE loss. Prepectoral smooth expanders had increased rates of malposition/rotation. Conclusions: TE surface type did not affect rates of TE loss, although increased rates of expander malposition were noted in the smooth prepectoral cohort. Further research is needed to examine breast implantassociated anaplastic large-cell lymphoma risk with temporary textured TE exposure to improve decision-making. CLINICAL QUESTION/LEVEL OF EVIDENCW: Therapeutic, III. Copyright (C) 2023 by the American Society of Plastic Surgeons
引用
收藏
页码:262e / 272e
页数:11
相关论文
共 50 条
  • [41] Capsular contracture with textured versus smooth saline-filled implants for breast augmentation: A prospective clinical study
    Tarpila, E
    Ghassemifar, R
    Fagrell, D
    Berggren, A
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (07) : 1934 - 1939
  • [42] Complications in unilateral versus bilateral deep inferior epigastric artery perforator flap breast reconstructions: A multicentre study
    Beugels, J.
    Hoekstra, L. T.
    Tuinder, S. M. H.
    Heuts, E. M.
    van der Hulst, R. R. W. J.
    Piatkowski, A. A.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2016, 69 (09): : 1291 - 1298
  • [43] Complications in DIEP Flap Breast Reconstruction After Mastectomy for Breast Cancer: A Prospective Cohort Study Comparing Unilateral Versus Bilateral Reconstructions
    Wade, Ryckie G.
    Razzano, Sergio
    Sassoon, Elaine M.
    Haywood, Richard M.
    Ali, Rozina S.
    Figus, Andrea
    ANNALS OF SURGICAL ONCOLOGY, 2017, 24 (06) : 1465 - 1474
  • [44] Complications in DIEP Flap Breast Reconstruction After Mastectomy for Breast Cancer: A Prospective Cohort Study Comparing Unilateral Versus Bilateral Reconstructions
    Ryckie G. Wade
    Sergio Razzano
    Elaine M. Sassoon
    Richard M. Haywood
    Rozina S. Ali
    Andrea Figus
    Annals of Surgical Oncology, 2017, 24 : 1465 - 1474
  • [45] A Comparison of Surgical Complications in Patients Undergoing Delayed versus Staged Tissue-Expander and Free-Flap Breast Reconstruction
    Shammas, Ronnie L.
    Cason, Roger W.
    Sergesketter, Amanda R.
    Glener, Adam D.
    Broadwater, Gloria
    Hollins, Andrew
    Le, Elliot
    Marks, Caitlin
    Atia, Andrew N.
    Orr, Jonah P.
    Hollenbeck, Scott T.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 148 (03) : 501 - 509
  • [46] Comparison of the Hospital Cost of Autograft Versus Allograft Soft-Tissue Anterior Cruciate Ligament Reconstructions
    Cooper, M. Truitt
    Kaeding, Christopher
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (11): : 1478 - 1482
  • [47] Reply to “Complications in DIEP Flap Breast Reconstruction After Mastectomy for Breast Cancer: A Prospective Cohort Study Comparing Unilateral Versus Bilateral Reconstructions”
    Ryckie G. Wade
    Sergio Razzano
    Elaine M. Sassoon
    Richard M. Haywood
    Justin C. R. Wormald
    Andrea Figus
    Annals of Surgical Oncology, 2017, 24 : 563 - 565
  • [48] Reply to "Complications in DIEP Flap Breast Reconstruction After Mastectomy for Breast Cancer: A Prospective Cohort Study Comparing Unilateral Versus Bilateral Reconstructions"
    Wade, Ryckie G.
    Razzano, Sergio
    Sassoon, Elaine M.
    Haywood, Richard M.
    Wormald, Justin C. R.
    Figus, Andrea
    ANNALS OF SURGICAL ONCOLOGY, 2017, 24 : S563 - S565
  • [49] Complication analysis of complete versus partial coverage of tissue expanders using serratus anterior musculofascial flaps in immediate breast reconstruction
    Kazuyuki Kubo
    Hiroyuki Takei
    Atsumori Hamahata
    Hiroshi Matsumoto
    Hiroyuki Sakurai
    Surgery Today, 2018, 48 : 703 - 708
  • [50] Complication analysis of complete versus partial coverage of tissue expanders using serratus anterior musculofascial flaps in immediate breast reconstruction
    Kubo, Kazuyuki
    Takei, Hiroyuki
    Hamahata, Atsumori
    Matsumoto, Hiroshi
    Sakurai, Hiroyuki
    SURGERY TODAY, 2018, 48 (07) : 703 - 708