An integrated approach to improve the assay performance of quantum dot-based lateral flow immunoassays by using silver deposition

被引:7
作者
Wang, Yulong [1 ,2 ,3 ]
Liu, Pengyan [1 ]
Ye, Yuhui [1 ]
Zhang, Cunzheng [1 ,3 ,5 ]
Hammock, Bruce D. [4 ]
机构
[1] Jiangsu Acad Agr Sci, Inst Food Safety & Nutr, State Key Lab Breeding Base, Key Lab Food Qual & Safety Jiangsu Prov,Minist Agr, Nanjing 210014, Peoples R China
[2] Jiangsu Univ, Sch Environm & Safety Engn, Zhenjiang 212013, Peoples R China
[3] Anhui Sci & Technol Univ, Fengyang 233100, Peoples R China
[4] Univ Calif Davis, UCD Comprehens Canc Ctr, Dept Entomol & Nematol, Davis, CA 95616 USA
[5] Jiangsu Univ, Sch Biol & Food Engn, Zhenjiang 212013, Peoples R China
基金
中国国家自然科学基金;
关键词
Quantum dot; Lateral flow immunoassay; Silver deposition; Sodium pentachlorophenate; Signal enhancement; GOLD NANOPARTICLE; AMPLIFICATION; OCHRATOXIN; ANTIBODY; RESIDUE;
D O I
10.1016/j.microc.2023.108932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditional quantum dot-based lateral flow immunoassay (QD-LFIA) is limited to signal loss in part by the blinking, photobleaching and oxidative quenching of QD probes. Inspired by the good application of silver deposition on QD surfaces in tissue imaging, and in the context of improving the assay performance without compromising the simplicity and practicality, we report that introducing the QD-silver combination to the LFIA system, has the advantages of accuracy improvement, signal enhancement and user friendliness promotion, but maintains the cost-effective property and commercial accessibility of QD-LFIA. The effect was shown by using CdSe/ZnS QD-LFIA coupled with anti-sodium pentachlorophenate antibody, which provided a 4-fold improvement in the signal, a 2.5-fold improvement in the detection limit and a zero false-negative rate for sodium pentachlorophenate analysis in chicken samples. The proposed LFIA integrates the possibilities of colorimetric and fluorometric detection with different detection limits (fluorometric at 10 ng/mL and colorimetric at 4 ng/ mL) and with acceptable detection times (fluorometric at 12 min and colorimetric at 27 min). The current results indicate that this QD-silver combined LFIA is complementary to conventional fluorescence LFIA and could be an inexpensive, versatile, and sensitive alternative.
引用
收藏
页数:8
相关论文
共 39 条
  • [1] Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement
    Anfossi, L.
    Di Nardo, F.
    Giovannoli, C.
    Passini, C.
    Baggiani, C.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (30) : 9859 - 9867
  • [2] [Anonymous], 2020, ANNOUNCEMENT NO 250
  • [3] Emerging 0D, 1D, 2D, and 3D nanostructures for efficient point-of-care biosensing
    Byakodi M.
    Shrikrishna N.S.
    Sharma R.
    Bhansali S.
    Mishra Y.
    Kaushik A.
    Gandhi S.
    [J]. Biosensors and Bioelectronics: X, 2022, 12
  • [4] Pretreatment-free immunochromatographic assay for the detection of streptomycin and its application to the control of milk and dairy products
    Byzova, N. A.
    Zvereva, E. A.
    Zherdev, A. V.
    Eremin, S. A.
    Sveshnikov, P. G.
    Dzantiev, B. B.
    [J]. ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 209 - 217
  • [5] Visualizing Quantum Dots in Biological Samples Using Silver Staining
    Chou, Leo Y. T.
    Fischer, Hans C.
    Perrault, Steve D.
    Chan, Warren C. W.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (11) : 4560 - 4565
  • [6] Antibody orientation enhanced by selective polymer-protein noncovalent interactions
    Clarizia, Lisa-Jo A.
    Sok, Davin
    Wei, Ming
    Mead, Joey
    Barry, Carol
    McDonald, Melisenda J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (05) : 1531 - 1538
  • [7] Recent advances in sensitivity enhancement for lateral flow assay
    Deng, Yulin
    Jiang, Hao
    Li, Xiaoqiong
    Lv, Xuefei
    [J]. MICROCHIMICA ACTA, 2021, 188 (11)
  • [8] Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives
    Di Nardo, Fabio
    Chiarello, Matteo
    Cavalera, Simone
    Baggiani, Claudio
    Anfossi, Laura
    [J]. SENSORS, 2021, 21 (15)
  • [9] Signal Amplification Strategy for Highly Sensitive Detecting Brombuterol with Electrochemiluminescent Immunoassay by Using CdSe QDs as Label and Gold Nanoparticle as Substrate
    Dong, Tiantian
    Yangxiao, Kete
    Zhao, Kang
    Deng, Anping
    Li, Jianguo
    [J]. ELECTROANALYSIS, 2016, 28 (08) : 1847 - 1855
  • [10] Coupling Sensitive Nucleic Acid Amplification with Commercial Pregnancy Test Strips
    Du, Yan
    Pothukuchy, Arti
    Gollihar, Jimmy D.
    Nourani, Armin
    Li, Bingling
    Ellington, Andrew D.
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (04) : 992 - 996