Cementless total hip arthroplasty for treatment of acetabular protrusion secondary to rheumatoid arthritis

被引:2
作者
Liu, Peng [1 ]
Qiao, Yong-jie [1 ]
Lou, Jin-peng [1 ]
Cao, Guoding [2 ]
Chang, Yanfeng [1 ]
Zhou, Sheng-hu [1 ]
机构
[1] Chinese Peoples Liberat Army, 940Th Hosp Joint Logist Support Force, Dept Joint Surg, South Binhe Rd, 333, Lanzhou 730050, Gansu, Peoples R China
[2] Lanzhou Univ, Dept Orthopaed, Hosp 2, Cuiying Gate,82, Lanzhou 730030, Gansu, Peoples R China
关键词
Total hip arthroplasty; Rheumatoid arthritis; Acetabular protrusion; Bone grafting; Cementless prosthesis; FOLLOW-UP; BONE; CUP; FIXATION;
D O I
10.1186/s13018-023-03764-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundTo explore the surgical technique and clinical outcomes of cementless total hip arthroplasty (THA) combined with impacted bone grafting for the treatment of moderate and severe acetabular protrusion with rheumatoid arthritis (RA).MethodsFrom January 2010 to October 2020, 45 patients (56 hips), including 17 men (22 hips) and 28 women (34 hips) with acetabular impingement secondary to RA, were treated with bioprosthetic THA combined with autologous bone grafting at our hospital. According to the Sotello-Garza and Charnley classification criteria, there were 40 cases (49 hips) of type II (protrusio acetabuli 6-15 mm) and 5 cases (7 hips) of type III (protrusio acetabuli > 15 mm). At the postoperative follow-up, the ROM of the hip joint, the VAS score, and the Harris score were evaluated. The healing of the bone graft, the restoration of the hip rotation center, and the prosthesis loosening were assessed by plain anteroposterior radiographs.ResultsThe average operation time was 95.53 +/- 22.45 min, and the mean blood loss was 156.16 +/- 69.25 mL. There were no neurovascular complications during the operation. The mean follow-up duration was 5.20 +/- 1.20 years. The horizontal distance of the hip rotation center increased from preoperative 10.40 +/- 2.50 mm to postoperative 24.03 +/- 1.77 mm, and the vertical distance increased from preoperative 72.36 +/- 3.10 mm to postoperative 92.48 +/- 5.31 mm. The range of flexion motion of the hip joint increased from 39.48 +/- 8.36 degrees preoperatively to 103.07 +/- 7.64 degrees postoperatively, and the range of abduction motion increased from 10.86 +/- 4.34 degrees preoperatively to 36.75 +/- 3.99 degrees postoperatively. At the last follow-up, the Harris score increased from 37.84 +/- 4.74 to 89.55 +/- 4.05. All patients were able to move independently without assistance.ConclusionsCementless THA combined with impacted grafting granule bone of the autogenous femoral head and biological acetabular cup can reconstruct the acetabulum, restore the rotation center of the hip joint, and achieve good medium-term outcomes in the treatment of moderate to severe acetabular herniation secondary to RA.
引用
收藏
页数:10
相关论文
共 29 条
[1]   Restoration of the Hip Center During THA Performed for Protrusio Acetabuli Is Associated With Better Implant Survival [J].
Baghdadi, Yaser M. K. ;
Larson, A. Noelle ;
Sierra, Rafael J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (10) :3251-3259
[2]  
Bayley J C, 1987, J Arthroplasty, V2, P275, DOI 10.1016/S0883-5403(87)80059-1
[3]  
Berend ME., 2015, ORTHOPEDICS, V31, P895
[4]   Surgical Technique: A Cup-in-Cup Technique to Restore Offset in Severe Protrusio Acetabular Defects [J].
Blumenfeld, Thomas J. ;
Bargar, William L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :435-441
[5]   Acetabular Reconstruction with Impaction Bone-Grafting and a Cemented Cup in Patients Younger than Fifty Years Old A Concise Follow-up, at Twenty to Twenty-eight Years, of a Previous Report [J].
Busch, Vincent J. J. F. ;
Gardeniers, Jean W. M. ;
Verdonschot, Nico ;
Slooff, Tom J. J. H. ;
Schreurs, B. Willem .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (04) :367-371
[6]  
Chinese Rheumatology Association, 2018, Zhonghua Nei Ke Za Zhi, V57, P242, DOI 10.3760/cma.j.issn.0578-1426.2018.04.004
[7]  
Coll GF, 2008, HIP INT, V18, P23
[8]   Middle term results of tantalum acetabular cups in total hip arthroplasty following pelvic irradiation [J].
De Paolis, Massimiliano ;
Zucchini, Riccardo ;
Romagnoli, Carlo ;
Romantini, Matteo ;
Mariotti, Federica ;
Donati, Davide Maria .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2019, 53 (03) :165-169
[9]   STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR [J].
DORR, LD ;
FAUGERE, MC ;
MACKEL, AM ;
GRUEN, TA ;
BOGNAR, B ;
MALLUCHE, HH .
BONE, 1993, 14 (03) :231-242
[10]  
Dutka Julian, 2011, Ortop Traumatol Rehabil, V13, P469