Reproducibility of subscapularis muscle thickness measurement using ultrasound imaging. -Relationship between subscapularis muscle thickness and internal rotation torque of the shoulder joint-

被引:0
作者
Homma, Hisashi [1 ,2 ]
Aoki, Mitsuhiro [1 ]
Okino, Kumiko [1 ]
Hayashi, Tomoya [1 ]
Yamane, Masahiro [1 ]
Sasaki, Yuji [1 ]
机构
[1] Hlth Sci Univ Hokkaido, Grad Sch Rehabil Sci, 1757 Kanazawa, Tobetsu, Hokkaido 0610293, Japan
[2] Sapporo Hachiken Orthoped Clin, Dept Rehabil, Hokkaido, Japan
关键词
Subscapularis muscle; Muscle thickness measurement; Ultrasound imaging; Intra-inter-rater reproducibility; Bland -altman analysis; Internal rotation torque; TRAPEZIUS MUSCLE; RELIABILITY; AGREEMENT; MRI;
D O I
10.1016/j.jbmt.2023.09.003
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Few studies have reported on the morphometry of the subscapularis muscle using ultrasound imaging (USI); and their reproducibility has not been verified. Objectives: This study aimed to clarify the relative and absolute reproducibility of USI measurements of subscapularis muscle thickness at rest and during isometric contraction as well as the degree of change in muscle thickness caused by the amount of internal rotational torque in the shoulder joint.Design: Two-group repeated-measures study. Methods: The subjects were the inferior fibers of the subscapularis muscle of 40 healthy adult males. Muscle thickness was measured at rest and at 10%-30% of the maximum isometric internal rotation torque. Intraclass correlation coefficients (ICC) and Brand Altman analysis were used for reproducibility measurement. The degree of change in muscle thickness at each torque was also calculated. Results: Intra- and inter-rater ICCs (ranged from 0.69 to 0.91) were good. A proportional error was observed in intra-rater measurements. Both minimal detectable change 95 (ranged from 2.33 to 6.47) were high. The sub-scapularis muscle thickness was significantly increased at 10% torque (25.49 +/- 3.80 mm), 20% torque (26.07 +/- 3.90 mm), and 30% torque (25.96 +/- 3.82 mm) as compared to that in resting conditions (24.53 +/- 4.46 mm) (p <0.05). Conclusion: The reproducibility and error of the subscapularis muscle thickness measurement using USI used in this study were clarified when repeated measurements were made in the same limb position and under the same probe installation conditions, suggesting that the contraction of the subscapularis muscle can be estimated by muscle thickness measurement.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 27 条
[1]   Multi-modal imaging of the subscapularis muscle [J].
Alilet M. ;
Behr J. ;
Nueffer J.-P. ;
Barbier-Brion B. ;
Aubry S. .
Insights into Imaging, 2016, 7 (6) :779-791
[2]  
Aluisio Frank V, 2003, Am J Orthop (Belle Mead NJ), V32, P124
[3]   Thickness of the middle trapezius muscle measured by rehabilitative ultrasound imaging: description of the technique and reliability study [J].
Bentman, Susanna ;
O'Sullivan, Cliona ;
Stokes, Maria .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2010, 30 (06) :426-431
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Comparison of changes in supraspinatus muscle thickness in persons with subacromial impingement syndrome and asymptomatic adults [J].
Blume, Christiana ;
Wang, Sharon S. .
PHYSIOTHERAPY THEORY AND PRACTICE, 2014, 30 (08) :544-551
[6]   Dynamic ultrasonography of rotator cuff muscles [J].
Boehm, TD ;
Kirschner, S ;
Mueller, T ;
Sauer, U ;
Gohlke, FE .
JOURNAL OF CLINICAL ULTRASOUND, 2005, 33 (05) :207-213
[7]   Real-time sonography to estimate muscle thickness: Comparison with MRI and CT [J].
Dupont, AC ;
Sauerbrei, EE ;
Fenton, PV ;
Shragge, PC ;
Loeb, GE ;
Richmond, FJR .
JOURNAL OF CLINICAL ULTRASOUND, 2001, 29 (04) :230-236
[8]   An MRI investigation into the function of the transversus abdominis muscle during "drawing-in" of the abdominal wall [J].
Hides, J ;
Wilson, S ;
Stanton, W ;
McMahon, S ;
Keto, H ;
McMahon, K ;
Bryant, M ;
Richardson, C .
SPINE, 2006, 31 (06) :E175-E178
[9]   Measurement of muscle contraction with ultrasound imaging [J].
Hodges, PW ;
Pengel, LHM ;
Herbert, RD ;
Gandevia, SC .
MUSCLE & NERVE, 2003, 27 (06) :682-692
[10]   Correlation between cervical flexor muscle thickness and craniocervical flexion torque in healthy subjects [J].
Ishida, Hiroshi ;
Suehiro, Tadanobu ;
Watanabe, Susumu .
JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2018, 22 (01) :118-121