Magneto-Acoustic Imaging in Biology

被引:1
作者
Roth, Bradley J. [1 ]
机构
[1] Oakland Univ, Dept Phys, Rochester, MI 48309 USA
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 06期
关键词
MAT-MI; MAET; magneto-acoustic imaging; electrical conductivity; Lorentz force; ACOUSTO-ELECTRICAL TOMOGRAPHY; INDUCED LORENTZ FORCE; MAGNETIC INDUCTION; RECONSTRUCTION; IMPEDANCE; RESOLUTION; MODELS;
D O I
10.3390/app13063877
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application Magneto-acoustic methods can be used to image electrical conductivity in biological samples. This review examines the use of magneto-acoustic methods to measure electrical conductivity. It focuses on two techniques developed in the last two decades: Magneto-Acoustic Tomography with Magnetic Induction (MAT-MI) and Magneto-Acousto-Electrical Tomography (MAET). These developments have the potential to change the way medical doctors image biological tissue.
引用
收藏
页数:16
相关论文
共 95 条
  • [1] A mathematical and numerical framework for ultrasonically-induced Lorentz force electrical impedance tomography
    Ammari, Habib
    Grasland-Mongrain, Pol
    Millen, Pierre
    Seppecher, Laurent
    Seo, Jin-Keun
    [J]. JOURNAL DE MATHEMATIQUES PURES ET APPLIQUEES, 2015, 103 (06): : 1390 - 1409
  • [2] Mathematical models and reconstruction methods in magneto-acoustic imaging
    Ammari, Habib
    Capdeboscq, Yves
    Kang, Hyeonbae
    Kozhemyak, Anastasia
    [J]. EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2009, 20 : 303 - 317
  • [3] The effect of electrical anisotropy during magnetoacoustic tomography with magnetic induction
    Brinker, Kaytlin
    Roth, Bradley J.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (05) : 1637 - 1639
  • [4] Research on Factors Affecting the Imaging Resolution of Magneto-Acousto-Electrical Tomography
    Dai, Ming
    Xu, Jinfeng
    Sun, Tong
    Qian, Chrisopher
    Chen, Mian
    Zeng, Xin
    Chen, Siping
    Hao, Penghui
    Li, Yunfeng
    Liu, Yingying
    Luo, Liangping
    [J]. IEEE ACCESS, 2020, 8 : 203457 - 203467
  • [5] A B-Scan Imaging Method of Conductivity Variation Detection for Magneto-Acousto-Electrical Tomography
    Dai, Ming
    Sun, Tong
    Chen, Xin
    Yu, Lingyao
    Chen, Mian
    Hao, Penghui
    Zeng, Xin
    Yan, Jiejie
    Chen, Siping
    [J]. IEEE ACCESS, 2019, 7 : 26881 - 26891
  • [6] A 2D Magneto-Acousto-Electrical Tomography Method to Detect Conductivity Variation Using Multifocus Image Method
    Dai, Ming
    Chen, Xin
    Sun, Tong
    Yu, Lingyao
    Chen, Mian
    Lin, Haoming
    Chen, Siping
    [J]. SENSORS, 2018, 18 (07)
  • [7] A Novel Method to Detect Interface of Conductivity Changes in Magneto-Acousto- Electrical Tomography Using Chirp Signal Excitation Method
    Dai, Ming
    Chen, Xin
    Chen, Mian
    Lin, Haoming
    Li, Fangfang
    Chen, Siping
    [J]. IEEE ACCESS, 2018, 6 : 33503 - 33512
  • [8] Image quality improvement of magneto-acousto-electrical tomography with Barker coded excitation
    Deng, Dingqian
    Sun, Tong
    Yu, Linguo
    Chen, Yi
    Chen, Xin
    Chen, Mian
    Chen, Siping
    Lin, Haoming
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 77
  • [9] Lorentz force induced shear waves for magnetic resonance elastography applications
    Fle, Guillaume
    Gilbert, Guillaume
    Grasland-Mongrain, Pol
    Cloutier, Guy
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [10] Numerical implementation of magneto-acousto-electrical tomography (MAET) using a linear phased array transducer
    Gozu, Mehmet Soner
    Zengin, Reyhan
    Gencer, Nevzat Guneri
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)