Effect of Hydrothermal Factors on the Microhardness of Bulk-Fill and Nanohybrid Composites

被引:2
|
作者
Pieniak, Daniel [1 ,2 ]
Niewczas, Agata M. M. [3 ]
Pikula, Konrad [3 ]
Gil, Leszek [2 ]
Krzyzak, Aneta [4 ]
Przystupa, Krzysztof [5 ]
Kordos, Pawel [6 ]
Kochan, Orest [7 ,8 ]
机构
[1] Lukasiewicz Res Network, Inst Sustainable Technol L ITEE, Tribol Ctr, Ul Pulaskiego 6-10, PL-26600 Radom, Poland
[2] WSEI Univ, Fac Transport & Comp Sci, Projektowa 4, PL-20209 Lublin, Poland
[3] Med Univ Lublin, Dept Conservat Dent Endodont, W Chodzki 6, PL-20093 Lublin, Poland
[4] Mil Univ Aviat Deblin, Fac Aeronaut, 35 Dywizjonu 303, PL-08521 Deblin, Poland
[5] Lublin Univ Technol, Dept Automat, Nadbystrzycka 36, PL-20618 Lublin, Poland
[6] Lublin Univ Technol, Inst Transport Combust Engines & Ecol, Nadbystrzycka 36, PL-20618 Lublin, Poland
[7] Hubei Univ Technol, Sch Comp Sci, Wuhan 430068, Peoples R China
[8] Lviv Polytech Natl Univ, Dept Measuring Informat Technol, Bandery Str 12, UA-79013 Lvov, Ukraine
关键词
bulk-fill dental composites; microhardness; thermocycling; hydrothermal degradation; DENTAL COMPOSITES; MECHANICAL-PROPERTIES; RESIN COMPOSITES; TRIBOLOGICAL PROPERTIES; RESTORATIVE MATERIALS; SURFACE HARDNESS; WEAR BEHAVIOR; TEMPERATURE; CONVERSION; FATIGUE;
D O I
10.3390/ma16052130
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study evaluates the effect of aging in artificial saliva and thermal shocks on the microhardness of the bulk-fill composite compared to the nanohybrid composite. Two commercial composites, Filtek Z550 (3M ESPE) (Z550) and Filtek Bulk-Fill (3M ESPE) (B-F), were tested. The samples were exposed to artificial saliva (AS) for one month (control group). Then, 50% of the samples from each composite were subjected to thermal cycling (temperature range: 5-55 degrees C, cycle time: 30 s, number of cycles: 10,000) and another 50% were put back into the laboratory incubator for another 25 months of aging in artificial saliva. The samples' microhardness was measured using the Knoop method after each stage of conditioning (after 1 month, after 10,000 thermocycles, after another 25 months of aging). The two composites in the control group differed considerably in hardness (HK = 89 for Z550, HK = 61 for B-F). After thermocycling, the microhardness decrease was for Z550 approximately 22-24% and for B-F approximately 12-15%. Hardness after 26 months of aging decreased for Z550 (approximately 3-5%) and B-F (15-17%). B-F had a significantly lower initial hardness than Z550, but it showed an approximately 10% lower relative reduction in hardness.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Effect of Light Curing Distance on Microhardness Profiles of Bulk-Fill Resin Composites
    Hasanain, Fatin A.
    Nassar, Hani M.
    Ajaj, Reem A.
    POLYMERS, 2022, 14 (03)
  • [2] Surface Microhardness of Bulk-Fill Resin Composites Handled With Gloves
    Berto-Inga, Julissa
    Santander-Rengifo, Flor
    Ladera-Castaneda, Marysela
    Lopez-Gurreonero, Carlos
    Perez-Vargas, Antonieta Castro
    Cornejo-Pinto, Alberto
    Cervantes-Ganoza, Luis
    Cayo-Rojas, Cesar
    INTERNATIONAL DENTAL JOURNAL, 2023, 73 (04) : 489 - 495
  • [3] MICROHARDNESS OF BULK-FILL COMPOSITE MATERIALS
    Kelic, Katarina
    Matic, Sanja
    Marovic, Danijela
    Klaric, Eva
    Tarle, Zrinka
    ACTA CLINICA CROATICA, 2016, 55 (04) : 607 - 614
  • [4] Effect of whitening mouthrinses on bulk-fill composites
    Berger, Sandrine Bittencourt
    Petri, Zanelli
    Hass, Viviane
    Guiraldo, Ricardo Danil
    Favaro, Jaqueline Costa
    Lopes, Murilo Baena
    Miranda Gonzalez, Alejandra Hortencia
    AMERICAN JOURNAL OF DENTISTRY, 2019, 32 (05): : 235 - 239
  • [5] The effect of preheating on microhardness and flexural strength of bulk-fill resin composites: an in-vitro study
    Kahnamouei, Mehdi Abed
    Bahari, Mahmoud
    Chaharom, Mohammad Esmaeel Ebrahimi
    Kimyai, Soodabeh
    Daneshpooy, Mehdi
    Katebi, Katayoun
    Elhami, Bahareh
    EUROPEAN ORAL RESEARCH, 2024, 58 (03) : 133 - 138
  • [6] Effect of bulk/incremental fill on internal gap formation of bulk-fill composites
    Furness, Alan
    Tadros, Marko Yousef
    Looney, Stephen W.
    Rueggeberg, Frederick A.
    JOURNAL OF DENTISTRY, 2014, 42 (04) : 439 - 449
  • [7] Influence of Curing Time on the Microbiological Behavior of Bulk-Fill Nanohybrid Resin Composites
    Ionescu, Andrei C.
    Comba, Allegra
    Brambilla, Eugenio
    Ilie, Nicoleta
    Breschi, Lorenzo
    Cadenaro, Milena
    Scotti, Nicola
    POLYMERS, 2021, 13 (17)
  • [8] Depth of Cure and Microhardness of a New Composite vs. Bulk-fill Composites
    Cetin, Ali Riza
    Hataysal, Ahmet Ercan
    Kaplan, Taibe Tokgoz
    Botsali, Murat Selim
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (05): : 53 - 59
  • [9] Influence of increment thickness on radiant energy and microhardness of bulk-fill resin composites
    Karacolak, Gamze
    Turkun, L. Sebnem
    Boyacioglu, Hayal
    Ferracane, Jack L.
    DENTAL MATERIALS JOURNAL, 2018, 37 (02) : 206 - 213
  • [10] Evaluation of Polymerization Shrinkage, Microhardness, and Depth of Cure of Different Types of Bulk-Fill Composites
    Ozdemir, Sergen
    Ayaz, Ilker
    Tuncer, Nurgul Cetin
    Barutcugil, Cagatay
    Dundar, Ayse
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2025,