Evaluation of Data Processing and Artifact Removal Approaches Used for Physiological Signals Captured Using Wearable Sensing Devices during Construction Tasks

被引:10
作者
Anwer, Shahnawaz [1 ]
Li, Heng [2 ,3 ]
Antwi-Afari, Maxwell Fordjour [4 ]
Mirza, Aquil Maud [1 ]
Rahman, Mohammed Abdul [1 ]
Mehmood, Imran [1 ]
Guo, Runhao [1 ]
Wong, Arnold Yu Lok [5 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg & Real Estate, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Res Ctr Director Construct Informat, Hong Kong, Peoples R China
[3] Hong Kong Polytech Univ, Dept Bldg & Real Estate, Informat & Construct Technol, Hong Kong, Peoples R China
[4] Aston Univ, Coll Engn & Phys Sci, Dept Civil Engn, Birmingham B4 7ET, England
[5] Hong Kong Polytech Univ, Dept Rehabil Sci, Hong Kong, Peoples R China
关键词
Artifact eradication; Construction health; Construction safety; Digital construction; Noise removal; Physiological signals; Sensing devices; INDEPENDENT COMPONENT ANALYSIS; NEAR-INFRARED SPECTROSCOPY; ISOLATED SHOULDER FATIGUE; SURFACE EMG SIGNALS; MOTION ARTIFACT; ELECTRODERMAL ACTIVITY; RESPIRATORY FREQUENCY; PERCEPTUAL RESPONSES; AUTOMATIC REMOVAL; ECG;
D O I
10.1061/JCEMD4.COENG-13263
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wearable sensing devices (WSDs) have enormous promise for monitoring construction worker safety. They can track workers and send safety-related information in real time, allowing for more effective and preventative decision making. WSDs are particularly useful on construction sites since they can track workers' health, safety, and activity levels, among other metrics that could help optimize their daily tasks. WSDs may also assist workers in recognizing health-related safety risks (such as physical fatigue) and taking appropriate action to mitigate them. The data produced by these WSDs, however, is highly noisy and contaminated with artifacts that could have been introduced by the surroundings, the experimental apparatus, or the subject's physiological state. These artifacts are very strong and frequently found during field experiments. So, when there is a lot of artifacts, the signal quality drops. Recently, artifacts removal has been greatly enhanced by developments in signal processing, which has vastly enhanced the performance. Thus, the proposed review aimed to provide an in-depth analysis of the approaches currently used to analyze data and remove artifacts from physiological signals obtained via WSDs during construction-related tasks. First, this study provides an overview of the physiological signals that are likely to be recorded from construction workers to monitor their health and safety. Second, this review identifies the most prevalent artifacts that have the most detrimental effect on the utility of the signals. Third, a comprehensive review of existing artifact-removal approaches were presented. Fourth, each identified artifact detection and removal approach was analyzed for its strengths and weaknesses. Finally, in conclusion, this review provides a few suggestions for future research for improving the quality of captured physiological signals for monitoring the health and safety of construction workers using artifact removal approaches.
引用
收藏
页数:21
相关论文
共 157 条
  • [1] Physiological demands during construction work
    Abdelhamid, TS
    Everett, JG
    [J]. JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT, 2002, 128 (05) : 427 - 437
  • [2] Wearable Sensing Technology Applications in Construction Safety and Health
    Ahn, Changbum R.
    Lee, SangHyun
    Sun, Cenfei
    Jebelli, Houtan
    Yang, Kanghyeok
    Choi, Byungjoo
    [J]. JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT, 2019, 145 (11)
  • [3] Employing spatially constrained ICA and wavelet denoising, for automatic removal of artifacts from multichannel EEG data
    Akhtar, Muhammad Tahir
    Mitsuhashi, Wataru
    James, Christopher J.
    [J]. SIGNAL PROCESSING, 2012, 92 (02) : 401 - 416
  • [4] AI-enabled remote and objective quantification of stress at scale
    Al-Jebrni, Abdulrhman H.
    Chwyl, Brendan
    Wang, Xiao Yu
    Wong, Alexander
    Saab, Bechara J.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 59
  • [5] Photoplethysmography and its application in clinical physiological measurement
    Allen, John
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) : R1 - R39
  • [6] Comparison of Motion Artefact Reduction Methods and the Implementation of Adaptive Motion Artefact Reduction in Wearable Electrocardiogram Monitoring
    An, Xiang
    Stylios, George K.
    [J]. SENSORS, 2020, 20 (05)
  • [7] Antczak K, 2019, Arxiv, DOI arXiv:1807.11551
  • [8] The effect of overhead drilling position on shoulder moment and electromyography
    Anton, D
    Shibley, LD
    Fethke, NB
    Hess, J
    Cook, TM
    Rosecrance, J
    [J]. ERGONOMICS, 2001, 44 (05) : 489 - 501
  • [9] EEG artifact removal-state-of-the-art and guidelines
    Antonio Urigueen, Jose
    Garcia-Zapirain, Begona
    [J]. JOURNAL OF NEURAL ENGINEERING, 2015, 12 (03)
  • [10] Antwi-Afari M. F., 2021, PROC 9 W AFRICA BUIL