Parametric design of photovoltaic louver integrated shading devices for west facade windows of office buildings in central China

被引:2
|
作者
Liang, Xiao [1 ]
Zhang, Hua [1 ,3 ]
Sun, Boxin [2 ]
机构
[1] Henan Univ Technol, Sch Architecture, Zhengzhou, Peoples R China
[2] Henan Univ Technol Design & Res Acad, Dept Architectural Elect, Zhengzhou, Peoples R China
[3] Henan Univ Technol, Sch Architecture, 100 Lianhua Rd, Zhengzhou 450001, Peoples R China
关键词
Photovoltaic shading integrated device (PVSD); Multi-objective optimization; Building west facade; Energy consumption; Indoor thermal; DOUBLE SKIN FACADE; ENERGY PERFORMANCE; METHODOLOGY;
D O I
10.1080/13467581.2024.2320326
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to improve the shading performance and power generation effect of Photovoltaic shading integrated devices (PVSDs) on the west facade of buildings in China, a multi-objective optimization design method is proposed in this paper. Taking a west-facing office building in Zhengzhou, Henan Province, as an example, a parametric model of photovoltaic (PV) louvers for windows on the west facade is established, and parametric design research is carried out on the energy-saving potential of PV louver shading systems. Based on the optimization objectives of power generation of PV louvers, indoor thermal discomfort hours, building cooling load and lighting energy consumption, the performance of the west facade office with PVSD under different design strategies was simulated, and the optimal design strategy was determined according to the preference of decision makers. Compared with the basic type without a non-shading model, the indoor lighting energy consumption of the optimized west facade PVSD is slightly increased. However, overall performance is improved, with a 35% reduction in cooling load, a decrease of 804.59 kWh in total energy consumption, and a shortened summer thermal discomfort time of 404 hours. The power generation of PV louvers can replace 46% of the total energy consumption of the room. The results show that the installation of PVSD on the west facade window is important for alleviating the overheating inside the room and improving the energy-saving and power generation potential of the room.
引用
收藏
页码:924 / 938
页数:15
相关论文
共 19 条
  • [1] Parametric design of photovoltaic louver integrated shading devices for west facade windows of office buildings in central China
    Liang, Xiao
    Zhang, Hua
    Sun, Boxin
    Journal of Asian Architecture and Building Engineering, 2024,
  • [2] Energy Production Analysis of Photovoltaic Shading Devices (PVSD) in Integrated Facade Systems (IFS)
    Ibraheem, Yahya
    Piroozfar, Poorang
    Farr, Eric R. P.
    Ravenscroft, Neil
    FRONTIERS IN BUILT ENVIRONMENT, 2020, 6
  • [3] Energy efficiency facade design in high-rise apartment buildings using the calculation of solar heat transfer through windows with shading devices
    Ha, P. T. H.
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE DEVELOPMENT IN CIVIL, URBAN AND TRANSPORTATION ENGINEERING (CUTE 2018), 2018, 143
  • [4] Kinetic Photovoltaic Facade System Based on a Parametric Design for Application in Signal Box Buildings in Switzerland
    Choi, Ho Soon
    APPLIED SCIENCES-BASEL, 2023, 13 (07):
  • [5] Photovoltaic Integrated Shading Devices in the Retrofitting of Existing Buildings on Chinese Campuses Within a Regional Context
    Cai, Zhiwen
    Zhang, Wenhao
    Chen, Jiajian
    Su, Ping
    BUILDINGS, 2024, 14 (11)
  • [6] Building Integrated Shading and Building Applied Photovoltaic System Assessment in the Energy Performance and Thermal Comfort of Office Buildings
    Martinopoulos, Georgios
    Serasidou, Anna
    Antoniadou, Panagiota
    Papadopoulos, Agis M.
    SUSTAINABILITY, 2018, 10 (12)
  • [7] PARAMETRIC DESIGN STUDY OF A PROPOSED PHOTOBIOREACTOR-INTEGRATED VERTICAL LOUVER SYSTEM FOR ENERGY-EFFICIENT BUILDINGS
    Woo, Deok-Oh
    Lee, Dawon
    Lee, Suk
    JOURNAL OF GREEN BUILDING, 2022, 17 (03):
  • [8] APPLICATION ANALYSIS OF PHOTOVOLTAIC INTEGRATED SHADING DEVICES CONSIDERING INDOOR ENVIRONMENT AND ENERGY CHANGE IN GREEN BUILDINGS
    Wang, Peng
    Wang, Wei
    Jia, Ling
    Wang, Chenglong
    Zhang, Wendi
    Huang, Lei
    JOURNAL OF GREEN BUILDING, 2024, 19 (03): : 71 - 90
  • [9] Design Optimisation of Fixed and Adaptive Shading Devices on Four Facade Orientations of a High-Rise Office Building in the Tropics
    Mangkuto, Rizki A.
    Koerniawan, Mochamad Donny
    Apriliyanthi, Sri Rahma
    Lubis, Irma Handayani
    Atthaillah
    Hensen, Jan L. M.
    Paramita, Beta
    BUILDINGS, 2022, 12 (01)
  • [10] Energy and Daylighting Evaluation of Integrated Semitransparent Photovoltaic Windows with Internal Light Shelves in Open-Office Buildings
    Mesloub, Abdelhakim
    Ghosh, Artira
    Albaqawy, Ghazy Abdullah
    Noaime, Emad
    Alsolami, Badr M.
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020