Effect of corrosion on self-centering energy dissipative devices

被引:4
作者
Fang, Cheng [1 ,2 ]
Cao, Chen [2 ]
Xiao, Yao [3 ,4 ]
Zheng, Yue [5 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[3] Tongji Univ, Sch Mech Engn, Shanghai 201804, Peoples R China
[4] Tongji Univ, Inst Adv Study, Shanghai 200092, Peoples R China
[5] Tongji Univ, Dept Bridge Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Self-centering damper; Corrosion; Shape memory alloy (SMA); Ring springs; Seismic resilience; SHAPE-MEMORY ALLOYS; EXPERIMENTAL VALIDATION; STEEL; PERFORMANCE; CONNECTIONS; SYSTEMS; BEHAVIOR; DAMPERS; ENHANCE; FRAMES;
D O I
10.1016/j.engstruct.2023.116664
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study reveals the effect of corrosion on the performance of typical self-centering energy dissipation devices for seismic resilience enhancement. Two types of SC devices, namely, high-strength steel ring spring-based SC damper (HSSR damper) and SMA ring spring-based SC damper (SMAR damper), are examined. These specimens were subjected to 720 h' accelerated corrosion, corresponding to roughly 20 years' exposure to city out-door environment. Numerical studies are carried out in ABAQUS to further interpret the test results. Among other important findings, the tests showed that the HSSR damper is likely to lose its self-centering capability after corrosion. The high-strength steel (HSS) rings were severely corroded, and the restoring force provided by the rings was insufficient to overcome the friction action. The SMAR damper showed much reduced sensitivity to corrosion. For both dampers, there was no damage to either the SMA/HSS rings or the other components under repeated loading, implying a low risk of corrosion-related low-cycle fatigue failure. The numerical study implies that the friction condition over the entire contact surface is not identical once the damper experiences corrosion. A "two-region modelling strategy" with a smaller friction coefficient and a larger friction coefficient leads to satisfactory agreements with the test results for the corroded HSSR damper. For the SMAR damper, a constant friction coefficient for the surfaces between inner and outer rings has been found to be appropriate for both noncorroded and corroded cases. Based on the limited experimental and numerical data, it is recommended that anticorrosion measurement should be mandatory for HSSR dampers. Overstrength due to the long-term effect should also be considered in the design of HSSR dampers from a life-cycle design point of view. If no special anticorrosion measurement is applied, an overstrength factor of 1.3 may be considered. Overstrength may be ignored for SMAR dampers. By representing the key components of SC devices as a group of springs, the analytical description of considered SC devices can be obtained.
引用
收藏
页数:20
相关论文
共 92 条
  • [21] Fang C., 2020, SHAPE MEMORY ALLOYS
  • [22] Self-Centering Energy-Dissipative Restrainers Incorporating SMA Ring Springs
    Fang, Cheng
    Cao, Chen
    Zheng, Yue
    Wu, Honglei
    Wang, Wei
    Liang, Dong
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (05)
  • [23] Self-Centering Structures Against Earthquakes: A Critical Review
    Fang, Cheng
    Qiu, Canxing
    Wang, Wei
    Alam, M. Shahria
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (15) : 4354 - 4389
  • [24] SMAs for infrastructures in seismic zones: A critical review of latest trends and future needs
    Fang, Cheng
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 57
  • [25] Seismic resilient steel structures: A review of research, practice, challenges and opportunities
    Fang, Cheng
    Wang, Wei
    Qiu, Canxing
    Hu, Shuling
    MacRae, Gregory A.
    Eatherton, Matthew R.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 191
  • [26] Probabilistic economic seismic loss estimation of steel braced frames incorporating emerging self-centering technologies
    Fang, Cheng
    Ping, Yiwei
    Zheng, Yue
    Chen, Yiyi
    [J]. ENGINEERING STRUCTURES, 2021, 241
  • [27] Development and Experimental Study of Disc Spring-Based Self-Centering Devices for Seismic Resilience
    Fang, Cheng
    Wang, Wei
    Shen, Deyang
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (07)
  • [28] Experimental and numerical studies on self-centring beam-to-column connections free from frame expansion
    Fang, Cheng
    Wang, Wei
    Feng, Weikang
    [J]. ENGINEERING STRUCTURES, 2019, 198
  • [29] Behavior and Design of Self-Centering Energy Dissipative Devices Equipped with Superelastic SMA Ring Springs
    Fang, Cheng
    Wang, Wei
    Zhang, Ao
    Sause, Richard
    Ricles, James
    Chen, Yiyi
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (10)
  • [30] Superelastic NiTi SMA cables: Thermal-mechanical behavior, hysteretic modelling and seismic application
    Fang, Cheng
    Zheng, Yue
    Chen, Junbai
    Yam, Michael C. H.
    Wang, Wei
    [J]. ENGINEERING STRUCTURES, 2019, 183 : 533 - 549