Negative stiffness and inerter-based dampers: Novel seismic response control approach for base isolated liquid storage tanks

被引:26
作者
Ul Islam, Naqeeb [1 ]
Jangid, R. S. [1 ]
机构
[1] Indian Inst Technol IIT Bombay, Dept Civil Engn, Mumbai 400076, India
关键词
Base-isolated liquid storage tanks; Inerters; Negative stiffness inerter dampers; Supplemental dampers; Seismic response control; Optimisation; OPTIMAL-DESIGN; VIBRATION; PERFORMANCE; EARTHQUAKE; PROTECTION; BEHAVIOR; SYSTEMS; DEVICE; DAMAGE;
D O I
10.1016/j.istruc.2024.105860
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Liquid storage tanks (LSTs) have become indispensable to civil engineering infrastructure. LSTs are used not only for storing harmless fluids but also explosive, toxic, and hazardous substances. Thus, the ability of LSTs to withstand significant seismic activity without damage is a major worry. Strong pulse-type characteristics in near fault (NF) type of ground motions have shown significant base and sloshing displacements for a commonly adopted structural control measure: base isolation (BI). The current study introduces negative stiffness and inerter dampers (NSIDs) as supplemental response control measures to LSTs with BI (BILSTs). Conventional supplemental damping applications in the isolation system are helpful in displacement reduction at the isolator level, but the upper structure response gets severely affected. This study presents NSIDs, characterised by the damping magnification effect, as supplemental dampers to BILSTs. The continuous liquid mass within the tank is represented by discrete lumped masses referred to as sloshing, impulsive, and rigid mass. The stiffness constants of these lumped masses are derived by considering the tank wall and stored liquid physical parameters. The optimal supplemental damping parameters are deduced by developing contour plots describing the sloshing and base displacement response reduction (mitigation) ratios. Through analytical studies conducted using real earthquake records, it has been demonstrated that appropriately designed Negative Stiffness and Inerter Devices (NSIDs) yield enhanced performance for Base Isolated Liquid Storage Tanks (BILSTs). These optimised combinations of NSIDs effectively mitigate isolator displacement, base shear, lumped sloshing mass displacement, and sloshing mass height in response to both near-field (NF) and far-field (FF) base excitations.
引用
收藏
页数:16
相关论文
共 73 条
[31]   Optimal design of a novel tuned mass-damper-inerter (TMDI) passive vibration control configuration for stochastically support-excited structural systems [J].
Marian, Laurentiu ;
Giaralis, Agathoklis .
PROBABILISTIC ENGINEERING MECHANICS, 2014, 38 :156-164
[32]   Performance-based semi-active control algorithm for protecting base isolated buildings from near-fault earthquakes [J].
Mehrparvar, Behnam ;
Khoshnoudian, Taramarz .
EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2012, 11 (01) :43-55
[33]  
Nagarajaiah S., 2010, PROC 5 WORLD C STRUC
[34]   Adaptive Stiffness Structures with Dampers: Seismic and Wind Response Reduction Using Passive Negative Stiffness and Inerter Systems [J].
Nagarajaiah, Satish ;
Chen, Lin ;
Wang, Meng .
JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (11)
[35]   BUCKLING OF CYLINDRICAL LIQUID-STORAGE TANKS UNDER EARTHQUAKE LOADING [J].
NIWA, A ;
CLOUGH, RW .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1982, 10 (01) :107-122
[36]   Optimal design of dual isolated structure with supplemental tuned inerter damper based on performance requirements [J].
Nyangi, Patrice ;
Ye, Kun .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 149
[37]   Behaviour of liquid storage tanks with VCFPS under near-fault ground motions [J].
Panchal, V. R. ;
Jangid, R. S. .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2012, 8 (01) :71-88
[38]   Seismic Response of Liquid Storage Steel Tanks with Variable Frequency Pendulum Isolator [J].
Panchal, V. R. ;
Jangid, R. S. .
KSCE JOURNAL OF CIVIL ENGINEERING, 2011, 15 (06) :1041-1055
[39]   Experimental Testing and Analysis of Inerter Devices [J].
Papageorgiou, Christos ;
Houghton, Neil E. ;
Smith, Malcolm C. .
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2009, 131 (01) :1-11
[40]   Experimental seismic performance assessment and numerical modelling of nonlinear inerter vibration absorber (IVA)-equipped base isolated structures tested on shaking table [J].
Pietrosanti, Daniele ;
De Angelis, Maurizio ;
Giaralis, Agathoklis .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (10) :2732-2753