A comparative study of low voltage, low contrast cerebral computed tomography angiography with iterative reconstruction and conventional cerebral computed tomography angiography

被引:0
作者
Mishra, Saurav [1 ,2 ]
Mishra, Sandeep [3 ]
Regmi, Sabina [4 ,6 ]
Gupta, Vivek [1 ,5 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Radiodiag & Imaging, Chandigarh, India
[2] Vayodha Hosp, Dept Radiodiag & Imaging, Kathmandu, Nepal
[3] Neo Multispecialty Hosp, Dept Neurosurg & Neurointervent, Noida, India
[4] Neo Multispecialty Hosp, Dept Anesthesia & Intens care, Noida, India
[5] Fortis Hosp, Dept Neurointervent Radiol, Gurgaon, India
[6] Neo Multispecialty Hosp, Dept Anesthesia & Intens care, Sect 50, Noida 201301, India
关键词
Cerebral angiography; radiation dose; image quality; low voltage; iterative reconstruction; ROW CT ANGIOGRAPHY; IMAGE-QUALITY; RADIATION-EXPOSURE; TUBE VOLTAGE; RISK; HEAD; REDUCTION; VOLUME;
D O I
10.1177/19714009231224412
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background: Cerebral computed tomography angiography (CTA) has revolutionized the diagnosis of neurovascular emergencies. Strategies to reduce radiation, a concern for cancer, involve tube voltage and current reduction but with increased noise and inferior image quality. Hence, the objective of the study was to evaluate the quality of images obtained through low-dose radiation and low-contrast volume CTA with an iterative reconstruction (IR) technique versus standard CTA without IR.Methods: This prospective trial involved 100 adults requiring cerebral CTA for cerebrovascular diseases. They were split into two groups: one with 120 kVp tube voltage and 80 mL contrast using filtered back projection, and the other with 80 kVp and 30 mL contrast with IR. Evaluation criteria included attenuation values, signal-to-noise ratio, contrast-to-noise ratio, and subjective assessments.Results: Compared to 120 kVp, 80 kVp showed higher vessel attenuation in the internal (272.91 +/- 30.59 vs 405.52 +/- 53.08; p < .001) and middle cerebral artery (247.55 +/- 29.84 vs 372.55 +/- 49.02; p < .001) regions. Brain parenchymal attenuation at the centrum semiovale was lower with 80 kVp (29.12 +/- 1.87 vs 24.78 +/- 2.94; p < .001), accompanied by higher noise. Signal-to-noise ratio (p < .001) and contrast-to-noise ratio (p < .05) were lower at 80 kVp. Image quality didn't significantly differ, and radiation exposure reduced significantly by 70% in the 80 kVp group, suggesting its diagnostic feasibility.Conclusions: The 80 kVp protocol for CTA of the cerebral vessels combined with lower contrast volume produces images with similar image quality with significant radiation effective dose and total iodine dose reduction. The 80 kVp protocol holds significant promise for replacing the standard 120 kVp protocol in cerebral CTA.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 24 条
[1]   Computed tomography angiography of the carotid arteries at low kV settings: a prospective randomised trial assessing radiation dose and diagnostic confidence [J].
Beitzke, Dietrich ;
Wolf, Florian ;
Edelhauser, Gundula ;
Plank, Christina ;
Schernthaner, Ruediger ;
Weber, Michael ;
Nolz, Richard ;
Lammer, Johannes ;
Loewe, Christian .
EUROPEAN RADIOLOGY, 2011, 21 (11) :2434-2444
[2]   Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[3]  
Bongartz G., 2004, European Guidelines for Multislice Computed Tomography Funded by the European Commission. Contract number FIGMCT2000- 20078-CT-TIP
[4]   Risk of Radiation-related Salivary Gland Carcinomas Among Survivors of Hodgkin Lymphoma A Population-based Analysis [J].
Boukheris, Houda ;
Ron, Elaine ;
Dores, Graca M. ;
Stovall, Marilyn ;
Smith, Susan A. ;
Curtis, Rochelle E. .
CANCER, 2008, 113 (11) :3153-3159
[5]   Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography [J].
Chen, Guo Zhong ;
Zhang, Long Jiang ;
Schoepf, U. Joseph ;
Wichmann, Julian L. ;
Milliken, Cole M. ;
Zhou, Chang Sheng ;
Qi, Li ;
Luo, Song ;
Lu, Guang Ming .
EUROPEAN RADIOLOGY, 2015, 25 (05) :1453-1463
[6]  
Cohnen M, 2006, AM J NEURORADIOL, V27, P1741
[7]   Preface, Executive Summary and Glossary [J].
Ann. ICRP, 2007, 2-4 (9-34) :9-34
[8]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[9]   Lowering the Dose in Head CT Using Adaptive Statistical Iterative Reconstruction [J].
Kilic, K. ;
Erbas, G. ;
Guryildirim, M. ;
Arac, M. ;
Ilgit, E. ;
Coskun, B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1578-1582
[10]   Sinogram affirmed iterative reconstruction in head CT: Improvement of objective and subjective image quality with concomitant radiation dose reduction [J].
Korn, A. ;
Bender, B. ;
Fenchel, M. ;
Spira, D. ;
Schabel, C. ;
Thomas, C. ;
Flohr, T. ;
Claussen, C. D. ;
Bhadelia, R. ;
Ernemann, U. ;
Brodoefel, H. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) :1431-1435