Bond Behavior of Recycled Tire Steel-Fiber-Reinforced Concrete and Basalt-Fiber-Reinforced Polymer Rebar after Prolonged Seawater Exposure

被引:1
作者
Soltanzadeh, Fatemeh [1 ]
Edalat-Behbahani, Ali [1 ]
Hosseinmostofi, Kasra [1 ]
Cengiz, Ibrahim Fatih [2 ,3 ]
Oliveira, Joaquim Miguel [2 ,3 ]
Reis, Rui L. [2 ,3 ]
机构
[1] Univ Minho, Sch Engn, Dept Civil Engn, Inst Sustainabil & Innovat Struct Engn ISISE, P-4800058 Guimaraes, Portugal
[2] Univ Minho, Res Inst Biomat Biodegradables & Biomimet I3Bs, Headquarters European Inst Excellence Tissue Engn, Res Grp 3Bs, AvePk,Parque Ciencia & Tecnol,Zona Ind Gandra, P-4805017 Guimaraes, Portugal
[3] PT Govt Associate Lab, ICVS 3Bs, P-4806909 Guimaraes, Portugal
关键词
bond durability; bond strength retention prediction; basalt-fiber-reinforced polymer; hybrid RTSF/ISF-reinforced concrete; pullout test; DURABILITY; BEAMS; BARS; PERFORMANCE; COMPOSITES;
D O I
10.3390/su152215856
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The integration of basalt-fiber-reinforced polymer (BFRP) rebars into concrete design standards still remains unrealized due to limited knowledge on the performance of the rebars in concrete, particularly in terms of bond durability in harsh conditions. In this work, we investigated the bond durability characteristics of BFRP rebars in fiber-reinforced self-compacting concrete (FRSCC) structures. To this aim, a number of 24 FRSCC pullout specimens reinforced with either BFRP rebar or glass-fiber-reinforced polymer, GFRP, rebar, which is a commonly used type of FRP, were fabricated. Half of these specimens were submerged in simulated seawater for a two-year span, while the other 12 similar specimens were maintained in standard laboratory conditions for comparative purposes. Subsequently, all 24 specimens underwent monotonic and fatigue pull-out tests. The exploration in this study focused on investigating the influence of the environmental condition, reinforcement type, and loading type on the bond stress versus slip relationship, maximum bond stress, and failure mode of the specimens. Based on the results obtained and by adopting the durability approach of industry standards for prediction of the bond retention of FRP-reinforced concrete, the bond strength retention between BFRP/GFRP and FRSCC after 50 years of exposure to seawater was estimated. The outcomes of the study are expected to enhance engineers' confidence in the use of FRP, especially BFRP, for constructing durable and sustainable reinforced concrete structures in aggressive environments.
引用
收藏
页数:25
相关论文
共 36 条
[1]   Effect of the strengthening patterns on the flexural performance of RC continuous beams using FRP reinforcements [J].
Abdallah, Mohammad ;
Al Mahmoud, Firas ;
Khalil, Nariman ;
Khelil, Abdelouahab .
ENGINEERING STRUCTURES, 2023, 280
[2]   Effect of basalt fibers on the flexural behavior of concrete beams reinforced with BFRP bars [J].
Abed, Farid ;
Alhafiz, Abdul Rahman .
COMPOSITE STRUCTURES, 2019, 215 :23-34
[3]  
ACI Committee 440, 2008, Specification for Carbon and Glass Fiber-Reinforced Polymer Bar Materials for Concrete Reinforcement (ACI 440.6M-08), P6
[4]  
[Anonymous], 2007, FIB Bulletin 40 FRP Reinforcement in RC Structures
[5]  
[Anonymous], 2014, ASTM C39/C39M-14
[6]  
[Anonymous], 2010, 123508 BS EN
[7]  
[Anonymous], 2002, MATER STRUCT, V35, P579, DOI [10.1617/14007, DOI 10.1617/13884, 10.1617/13884]
[8]  
[Anonymous], 2004, ASTM D1141-98
[9]  
[Anonymous], 2014, BS EN 12390-13
[10]   A new method for pull out test of reinforcing bars in plain and fibre reinforced concrete [J].
Chu, S. H. ;
Kwan, A. K. H. .
ENGINEERING STRUCTURES, 2018, 164 :82-91