Optimization of power feedback control system for HCN interferometer on EAST Tokamak

被引:1
|
作者
Zhang, J. B. [1 ]
Liu, H. Q. [1 ]
Zhang, Y. [1 ]
Jie, Y. . X. [1 ]
Wei, X. C. [1 ]
Xie, J. X. [1 ,2 ]
Wang, S. X. [1 ]
Lian, H. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, 350 ShuShanHu Rd, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, 96 JinZhai Rd, Hefei 230026, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 11期
关键词
Nuclear instruments and methods for hot plasma diagnostics; Plasma diagnostics-interferometry; spectroscopy and imaging; INFRARED LASER INTERFEROMETER; DIAGNOSTICS;
D O I
10.1088/1748-0221/18/11/C11016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Hydrogen Cyanide (HCN) interferometer stands as an indispensable diagnostic tool, designated to measure the line-integrated electron density on the Experimental Advanced Superconducting Tokamak (EAST), thereby offering essential density feedback signals for EAST operation. The HCN laser used in the interferometer is a continuous glow discharge gas laser. However, owing to variations in external ambient temperature, the HCN laser exhibits output power instability. The current power automatic feedback control system for the HCN laser interferometer exhibits low actuator adjustment precision, thereby limiting its ability to achieve maximum output power. Moreover, the system may cause a temporary power drop to zero during adjustment, while EAST operation requires the HCN laser interferometer to maintain high power continuously. In order to solve the issues, this paper developed an innovative actuator that ingeniously amalgamates the virtues of piezoelectric ceramic and stepper motor. This novel actuator, demonstrating a broad adjustment range and high precision, is intended to replace the present one in the HCN interferometer power control system. While the stepper motor executes coarse adjustment, the piezoelectric ceramic enables precise adjustment, thus enhancing the adjustment accuracy of the automatic power control system to a sub-micrometer level and an adjustment range greater than 5 mm. Accurate determination of the regulator's adjustment direction can significantly improve the efficiency of adjustment. The slope of the laser output power peak decreases as it approaches the maximum value, and increases as it moves away from the maximum value. Therefore, this system replaces the original threshold algorithm with a slope algorithm. By correctly judging the adjustment direction, the efficiency of adjustment is improved. Furthermore, this algorithm can keep the output power stable on a power peak. There will be no instances of zero power output during the adjustment, allowing the power to remain stable above the set threshold for a long time. Currently, this system has been successfully applied to the HCN interferometer, and testing has found that the system can maintain stability for at least 16 hours. Furthermore, even when the laser output power was intentionally reduced to below the set threshold, the system was able to respond quickly and adjust the output, rapidly restoring it to above the predefined threshold. Multiple tests have shown the strong robustness of the system, indicating it meets the stringent demands of the EAST's complex environment.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Bench Test of the Vibration Compensation Interferometer for EAST Tokamak
    李恭顺
    杨曜
    刘海庆
    揭银先
    邹志勇
    王正兴
    曾龙
    魏学朝
    李维明
    兰婷
    朱翔
    刘煜锴
    高翔
    Plasma Science and Technology, 2016, (02) : 206 - 210
  • [32] Optimization for Tokamak Reactive Power Compensation and Filtering System
    Yanan Wu
    Yue Ji
    Liuwei Xu
    Peng Fu
    Huafeng Mao
    Jun Li
    Qi Guo
    Journal of Fusion Energy, 2015, 34 : 54 - 61
  • [33] Optimization for Tokamak Reactive Power Compensation and Filtering System
    Wu, Yanan
    Ji, Yue
    Xu, Liuwei
    Fu, Peng
    Mao, Huafeng
    Li, Jun
    Guo, Qi
    JOURNAL OF FUSION ENERGY, 2015, 34 (01) : 54 - 61
  • [34] Multi-channel FIR HCN laser interferometer on HT-7 tokamak
    Jie, YX
    Gao, X
    Cheng, YF
    Yang, K
    Tong, XD
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2000, 21 (09): : 1375 - 1380
  • [35] Multi-Channel FIR HCN Laser Interferometer on HT-7 Tokamak
    Y. X. Jie
    X. Gao
    Y. F. Cheng
    K. Yang
    X. D. Tong
    International Journal of Infrared and Millimeter Waves, 2000, 21 : 1375 - 1380
  • [36] Optimization of the power supply demand for plasma shape control in a tokamak
    Albanese, R
    Ambrosino, G
    Pironti, A
    Fresa, R
    Portone, A
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) : 3580 - 3583
  • [37] Improved density measurement by FIR laser interferometer on EAST tokamak
    Shen Jie
    Jie Yinxian
    Liu Haiqing
    Wei Xuechao
    Wang Zhengxing
    Gao Xiang
    FUSION ENGINEERING AND DESIGN, 2013, 88 (11) : 2830 - 2834
  • [38] Design of power and phase feedback control system for ion cyclotron resonance heating in the Experimental Advanced Superconducting Tokamak
    Liu, L. N.
    Zheng, W. M.
    Zhang, X. J.
    Yang, H.
    Yuan, S.
    Mao, Y. Z.
    Zhang, W.
    Zhu, G. H.
    Wang, L.
    Qin, C. M.
    Zhao, Y. P.
    Cheng, Y.
    Zhang, K.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (01) : 216 - 221
  • [39] MULTICHANNEL INTERFEROMETER POLARIMETER SYSTEM FOR THE RTP TOKAMAK
    VANLAMMEREN, ACAP
    KIM, SK
    DONNE, AJH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2882 - 2884
  • [40] Study of the DEF Feedback Control System in AC Operation of Superconducting Tokamak
    王华
    罗家融
    袁旗平
    徐从东
    Plasma Science and Technology, 2007, 9 (01) : 106 - 109