Optimization of power feedback control system for HCN interferometer on EAST Tokamak

被引:1
|
作者
Zhang, J. B. [1 ]
Liu, H. Q. [1 ]
Zhang, Y. [1 ]
Jie, Y. . X. [1 ]
Wei, X. C. [1 ]
Xie, J. X. [1 ,2 ]
Wang, S. X. [1 ]
Lian, H. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, 350 ShuShanHu Rd, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, 96 JinZhai Rd, Hefei 230026, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 11期
关键词
Nuclear instruments and methods for hot plasma diagnostics; Plasma diagnostics-interferometry; spectroscopy and imaging; INFRARED LASER INTERFEROMETER; DIAGNOSTICS;
D O I
10.1088/1748-0221/18/11/C11016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Hydrogen Cyanide (HCN) interferometer stands as an indispensable diagnostic tool, designated to measure the line-integrated electron density on the Experimental Advanced Superconducting Tokamak (EAST), thereby offering essential density feedback signals for EAST operation. The HCN laser used in the interferometer is a continuous glow discharge gas laser. However, owing to variations in external ambient temperature, the HCN laser exhibits output power instability. The current power automatic feedback control system for the HCN laser interferometer exhibits low actuator adjustment precision, thereby limiting its ability to achieve maximum output power. Moreover, the system may cause a temporary power drop to zero during adjustment, while EAST operation requires the HCN laser interferometer to maintain high power continuously. In order to solve the issues, this paper developed an innovative actuator that ingeniously amalgamates the virtues of piezoelectric ceramic and stepper motor. This novel actuator, demonstrating a broad adjustment range and high precision, is intended to replace the present one in the HCN interferometer power control system. While the stepper motor executes coarse adjustment, the piezoelectric ceramic enables precise adjustment, thus enhancing the adjustment accuracy of the automatic power control system to a sub-micrometer level and an adjustment range greater than 5 mm. Accurate determination of the regulator's adjustment direction can significantly improve the efficiency of adjustment. The slope of the laser output power peak decreases as it approaches the maximum value, and increases as it moves away from the maximum value. Therefore, this system replaces the original threshold algorithm with a slope algorithm. By correctly judging the adjustment direction, the efficiency of adjustment is improved. Furthermore, this algorithm can keep the output power stable on a power peak. There will be no instances of zero power output during the adjustment, allowing the power to remain stable above the set threshold for a long time. Currently, this system has been successfully applied to the HCN interferometer, and testing has found that the system can maintain stability for at least 16 hours. Furthermore, even when the laser output power was intentionally reduced to below the set threshold, the system was able to respond quickly and adjust the output, rapidly restoring it to above the predefined threshold. Multiple tests have shown the strong robustness of the system, indicating it meets the stringent demands of the EAST's complex environment.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] HCN laser interferometer on the EAST superconducting tokamak
    Xu Qiang
    Gao Xiang
    Jie Yinxian
    Liu Haiqing
    Shi Nan
    Cheng Yongfei
    Tong Xingde
    PLASMA SCIENCE & TECHNOLOGY, 2008, 10 (04) : 519 - 521
  • [2] HCN Laser Interferometer on the EAST Superconducting Tokamak
    徐强
    高翔
    揭银先
    刘海庆
    史楠
    程永飞
    童兴德
    Plasma Science and Technology, 2008, (04) : 519 - 521
  • [3] HCN Laser Interferometer on the EAST Superconducting Tokamak
    徐强
    高翔
    揭银先
    刘海庆
    史楠
    程永飞
    童兴德
    Plasma Science and Technology, 2008, 10 (04) : 519 - 521
  • [4] Optimization of the HCN interferometer on J-TEXT tokamak
    Shi, P.
    Gao, L.
    Xiong, C. Y.
    Liu, Y.
    Chen, J.
    Zhuang, G.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [5] Output power stability of a HCN laser using a stepping motor for the EAST interferometer system
    Zhang, J. B.
    Wei, X. C.
    Liu, H. Q.
    Shen, J. J.
    Zeng, L.
    Jie, Y. X.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [6] THE HCN-LASER-INTERFEROMETER OF THE DIVERTOR TOKAMAK ASDEX
    GEHRE, O
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1984, 5 (03): : 369 - 379
  • [7] Improvement of q profile by the polarimeter/interferometer system on EAST tokamak
    Zhu, X.
    Zeng, L.
    Liu, H.
    Qian, J.
    Zang, Q.
    Jie, Y.
    Zou, Z.
    Li, W.
    Yao, Y.
    Gao, X.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [8] Density profile evolution on EAST tokamak by the polarimeter/interferometer system
    Zhu, X.
    Zeng, L.
    Liu, H. Q.
    Jie, Y. X.
    Yang, Y.
    Gao, X.
    FUSION ENGINEERING AND DESIGN, 2018, 131 : 29 - 32
  • [9] Central control system for the EAST tokamak
    Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China
    不详
    Hejubian Yu Dengliziti Wuli, 2008, 4 (352-356):
  • [10] Development of an HCN dual laser for the interferometer on EAST
    李根
    魏学朝
    刘海庆
    申俊杰
    揭银先
    连辉
    曾龙
    邹志勇
    张际波
    王守信
    Plasma Science and Technology, 2017, 19 (08) : 41 - 46