Effect of material type, torque value, and sterilization on linear displacements of a scan body: An in vitro study

被引:21
作者
Diker, Emre [1 ,2 ]
Terzioglu, Hakan [2 ]
Gouveia, Diogo N. M. [3 ]
Donmez, Mustafa Borga [4 ,5 ,8 ]
Seidt, Jeremy [3 ,6 ]
Yilmaz, Burak [3 ,4 ,7 ]
机构
[1] Med Dis Dent Clin, Private Practice, Ankara, Turkiye
[2] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkiye
[3] Ohio State Univ Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH USA
[4] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[5] Istinye Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[6] Ohio State Univ Coll Engn, Dept Mech & Aerosp Engn, Columbus, OH USA
[7] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[8] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
关键词
linear displacement; polyetheretherketone; scan body; sterilization; titanium; torque value; AXIAL DISPLACEMENT; IMPLANT IMPRESSION; SCREW; ABUTMENTS; CONNECTION; TRUENESS; CROWNS;
D O I
10.1111/cid.13187
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: There is limited knowledge on the effect of scan body (SB) material type, torque value, and sterilization on linear displacements of implant SBs. Purpose: To evaluate the effect of material type, torque value, and sterilization on linear displacements of SBs during screw tightening by using digital image correlation (DIC) analysis. Materials and Methods: One polyetheretherketone (PEEK, Zfx Intraoral Scan Body) and one titanium SB (Ti, MPS Zimmer Scanbody R1410) were tightened with 5 Ncm torque on two implants (Zimmer TSV circle divide 4.7 mm) by using a digital torque limiting device. SBs' initial spatial positions relative to the implants were recorded by using 3D DIC technique. Measurements were repeated after initially increasing torque value to 10 Ncm and then to 15 Ncm, and these steps were repeated for a total of 10 PEEK and 10 Ti SBs on both implants (n = 20). All SBs were then sterilized 25 times by using an autoclave (STATIM 5000 S G4) according to manufacturer's recommendations and all measurements were repeated. Linear displacements on three axes were calculated for each SB with increasing torque values (from 5 to 10 Ncm and from 10 to 15 Ncm) before and after sterilization. SB displacements within each torque value-sterilization pair were compared by using Mann-Whitney U test, whereas Wilcoxon signed-rank test was used to compare SB displacements within each material-torque value pair between conditions and within each material-sterilization pair between torque values (alpha = 0.05). Results: On x-axis, PEEK SBs had higher displacements than Ti SBs (p < 0.001), whereas sterilization (p <= 0.028) and 15 Ncm torque application (p <= 0.006) led to higher displacements of PEEK SBs. On y-axis, PEEK SBs had higher displacements than Ti SBs with 15 Ncm torque application (p <= 0.033). A total of 15 Ncm torque-applied PEEK SBs and 10 Ncm torque-applied Ti SBs had higher displacements after sterilization (p <= 0.028). Application of 15 Ncm torque led to higher displacements regardless of the material (p <= 0.002). On z-axis, PEEK SBs had higher displacements (p <= 0.015), except for 10 Ncm torque-applied sterilized SBs (p = 0.102). With 10 Ncm torque application, sterilization decreased the displacement values of PEEK SBs (p = 0.044). Greater displacements were observed with 10 Ncm torque-applied Ti SBs before sterilization and 15 Ncm torque-applied PEEK SBs after sterilization (p <= 0.033). Conclusions: Axial displacement of SBs was affected by material type, torque value, and sterilization. Ti SBs mostly had lower displacements than PEEK SBs. Application of 15 Ncm torque to tested PEEK SBs should be refrained from and a calibrated tightening tool may enable the application of 10 Ncm or lower torque values for lower displacements. Sterilization generally increased PEEK SB displacements.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 28 条
[1]   Clinician-generated torque on abutment screws using different hand screwdrivers [J].
Alikhasi, Marzieh ;
Kazemi, Mahmoud ;
Jalali, Hamid ;
Hashemzadeh, Shervin ;
Dodangeh, Hamide ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04) :488-492
[2]  
[Anonymous], 2022, ZFX DENT
[3]   The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans [J].
Cakmak, Gulce ;
Yilmaz, Hakan ;
Trevino, Alejandro ;
Kokat, Ali Murat ;
Yilmaz, Burak .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) :533-541
[4]  
Dailey B, 2009, INT J ORAL MAX IMPL, V24, P251
[5]   Congruence between the meshes of a combined healing abutment-scan body system acquired with four different intraoral scanners and the corresponding library file: An in vitro analysis [J].
Donmez, Mustafa Borga ;
Marques, Vinicius Rizzo ;
Cakmak, Gulce ;
Yilmaz, Hakan ;
Schimmel, Martin ;
Yilmaz, Burak .
JOURNAL OF DENTISTRY, 2022, 118
[6]   In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions [J].
Ender, Andreas ;
Attin, Thomas ;
Mehl, Albert .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (03) :313-320
[7]   Three-Dimensional Displacement of Nine Different Abutments for an Implant with an Internal Hexagon Platform [J].
Gilbert, Andy B. ;
Yilmaz, Burak ;
Seidt, Jeremy D. ;
McGlumphy, Edwin A. ;
Clelland, Nancy L. ;
Chien, Hua-Hong .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (04) :781-788
[8]   Cement fixation and screw retention:: parameters of passive fit -: An in vitro study of three-unit implant-supported fixed partial dentures [J].
Heckmann, SM ;
Karl, M ;
Wichmann, MG ;
Winter, W ;
Graef, F ;
Taylor, TD .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :466-473
[9]   Displacement and performance of abutments in narrow-diameter implants with different internal connections [J].
Jacobs, Nicholas ;
Seghi, Robert ;
Johnston, William M. ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01) :100-106
[10]   Displacement of scan body during screw tightening: A comparative in vitro study [J].
Kim, JungHan ;
Son, KeunBaDa ;
Lee, Kyu-Bok .
JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (05) :307-315