Optical Microscopy Image Restoration and Its Application in Strain Measurements Using the Digital Image Correlation Method

被引:2
|
作者
Han Wei [1 ]
Wu Dan [1 ]
机构
[1] Ningbo Univ, Sch Mech Engn & Mech, Ningbo 315211, Zhejiang, Peoples R China
关键词
image processing; digital image correlation; image restoration; noise removal; micro-scale; deformation measurement; PATTERNS; MOTION; FIELD;
D O I
10.3788/LOP221822
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As a direct and effective non-contact full-field optical measurement method, the digital image correlation method has been widely used in 2D/3D displacement and strain measurements of materials and structures in various fields. Combined with advanced speckle preparation technology, in situ loading experiments are conducted under a microscope, which can realize the displacement and strain measurements of micro-scale digital image correlation. Out-of-plane displacement inevitably occurs in the loading process of specimens at the micro scale. Because of the limitations of the depth of field of optical microscopes, small out-of-plane displacement leads to defocus blurring of speckle images, which generates a corresponding error in deformation measurements. To reduce the error caused by out-of-focus blur, the blind deconvolution method is used to blur the speckle image, and the Gaussian filtering method is used to denoise the speckle image to address noise problems. The effects of image restoration on the digital image correlation measurement accuracy are analyzed quantitatively, and a stretching experiment of an indium tin oxide (ITO) film is conducted. Experimental results show that the error in elastic modulus measurement after image restoration is reduced by 13. 91%, and the accuracy and stability of the strain measurement results are higher.
引用
收藏
页数:11
相关论文
共 41 条
  • [1] Image restoration via improved Wiener filter applied to optical sparse aperture systems
    Chen, Hao
    Cen, Zhaofeng
    Wang, Chuanchuan
    Lan, Shun
    Li, Xiaotong
    [J]. OPTIK, 2017, 147 : 350 - 359
  • [2] Chen X P, 2011, Confocal microscopy image restoration and regularization methods
  • [3] Speckle Quality Evaluation Based on Gray Level Co-Occurrence Matrix
    Chu Lu
    Liu Bin
    Xu Liang
    Li Zhiwei
    Zhang Baofeng
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (04)
  • [4] Gu G Q, 2012, Chinese Journal of Lasers,, V39
  • [5] He N, 2013, Laser & Optoelectronics Progress, V50
  • [6] Holmes Timothy J., 1995, P389
  • [7] A New Pattern Quality Assessment Criterion and Defocusing Degree Determination of Laser Speckle Correlation Method
    Hu, Wenxin
    Sheng, Zhipeng
    Yan, Keyu
    Miao, Hong
    Fu, Yu
    [J]. SENSORS, 2021, 21 (14)
  • [8] Hu X L, 2006, Digital image processing
  • [9] Micro-scale deformation measurement using the digital image correlation technique and scanning electron microscope imaging
    Jin, H.
    Lu, W-Y
    Korellis, J.
    [J]. JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2008, 43 (08): : 719 - 728
  • [10] Self-Assembled Nanoparticle Surface Patterning for Improved Digital Image Correlation in a Scanning Electron Microscope
    Kammers, A. D.
    Daly, S.
    [J]. EXPERIMENTAL MECHANICS, 2013, 53 (08) : 1333 - 1341