Hollow-fiber liquid phase microextraction for determination of fluoxetine in human serum by nano-liquid chromatography coupled to high resolution mass spectrometry

被引:4
作者
Cestaro, Beatriz Isabella [1 ]
Machado, Kelly Cavalcanti [2 ]
Batista, Michel [2 ]
da Silva, Bruno Jose Goncalves [1 ]
机构
[1] Univ Fed Parana, Dept Chem, BR-81531980 Curitiba, Brazil
[2] Fiocruz MS, Carlos Chagas Inst, Mass Spectrometry Facil RPT02H, BR-81350010 Curitiba, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2024年 / 1234卷
关键词
Human serum; Fluoxetine; nano; -LC; -MS; HF-LPME; High resolution mass spectrometry; HUMAN PLASMA; SAMPLE PREPARATION; BIOLOGICAL-FLUIDS; WATER SAMPLES; LC-MS/MS; DRUGS; NORFLUOXETINE; EXTRACTION; OLANZAPINE; PRECONCENTRATION;
D O I
10.1016/j.jchromb.2024.124018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Therapeutic drug monitoring (TDM) is a personalized care tool based on the determination of a target drug concentration in human serum. An antidepressant drug of interest for such investigations is fluoxetine (FXT), due to a severe impact of genetic polymorphisms on its metabolism. A bioanalytical method employed for TDM purposes must exhibit satisfactory selectivity and detectability, which becomes more difficult due to highly complex biological matrices. In this study, a highly selective bioanalytical method for the determination of FXT in human serum is proposed, which provides excellent clean-up efficiency based on a low cost hollow fiber liquid-phase microextraction (HF-LPME) sample preparation step and nano-liquid chromatography coupled to high-resolution mass spectrometry (nano-LC-HRMS). HF-LPME was performed using a two-phase "U" configuration, with 6 cm fiber, 20 mu L of 1-octanol acting as supported liquid membrane, and ammonium hydroxide (pH 10) as the donor phase with NaCl (10 % m/v) and methanol (5 % v/v) as additives, requiring only 250 mu L of the sample. The procedure was conducted for 30 min under a 750 rpm stirring rate. Gradient elution was carried out employing an acetonitrile-water as mobile phase, the composition of 30:70 to 100:00 (v/v) for 15 min, using formic acid 0.1 % (v/v) as an additive. MS1 was acquired in an Orbitrap mass analyzer, while MS2 was acquired in a linear trap quadrupole. Satisfactory linearity (Pearson's r = 0.99709) was obtained for a concentration range of 0.02 to 2.5 mu g mL-1, which is compatible with the therapeutic and toxic range for FXT. The developed method presents adequate precision (1.61 to 7.45 %) and accuracy (95 to 114 %) and allows the dilution of high concentration samples in a 1:4 ratio (v/v), enabling its application for forensic serum samples. To our knowledge, this is the first study reporting a method based on HF-LPME and nano-LC-HRMS with any analytical purpose, especially with a TDM focus.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Hollow fiber based liquid phase microextraction for the determination of organochlorine pesticides in ecological textiles by gas chromatography-mass spectrometry
    Cai, Jin'an
    Chen, Guosheng
    Qiu, Junlang
    Jiang, Ruifen
    Zeng, Feng
    Zhu, Fang
    Ouyang, Gangfeng
    [J]. TALANTA, 2016, 146 : 375 - 380
  • [42] Hollow fiber-based liquid membrane microextraction combined with high-performance liquid chromatography for extraction and determination of trimetazidine in human plasma
    Lv, Jiang
    Zhao, Xu
    Ye, Jing
    Liu, Dan
    Chen, Xiaohui
    Bi, Kaishun
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (03) : 292 - 298
  • [43] Determination of Triazole Fungicides Using Hollow Fiber Liquid Phase Microextraction Prior to Gas Chromatography-Mass Spectrometry Analysis
    Sarafraz-Yazdi, Ali
    Assadi, Hakimeh
    Ibrahim, Wan Aini Wan
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (07) : 3101 - 3107
  • [44] Determination of phthalic acid esters in water samples by hollow fiber liquid-phase microextraction prior to gas chromatography tandem mass spectrometry
    Gonzalez-Salamo, Javier
    Angel Gonzalez-Curbelo, Miguel
    Socas-Rodriguez, Barbara
    Hernandez-Borges, Javier
    Angel Rodriguez-Delgado, Miguel
    [J]. CHEMOSPHERE, 2018, 201 : 254 - 261
  • [45] Determination of rodenticides and related metabolites in rabbit liver and biological matrices by liquid chromatography coupled to Orbitrap high resolution mass spectrometry
    Lopez-Garcia, Marina
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 137 : 235 - 242
  • [46] Determination of alkaloids in Corydalis yanhusuo using hollow-fibre liquid phase microextraction and high performance liquid chromatography
    Lu, Huawei
    Sun, Huanquan
    Liu, Xia
    Jiang, Shengxiang
    [J]. CHEMICAL PAPERS, 2009, 63 (03): : 351 - 357
  • [47] Optimization of hollow-fiber liquid phase microextraction for polychlorinated biphenyls in human breast milk
    Villegas-Alvarez, M. C.
    Callejon-Leblic, B.
    Rodriguez-Moro, G.
    Gomez-Ariza, J. L.
    Arias-Borrego, A.
    Garcia-Barrera, T.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2020, 1626 (1626)
  • [48] Determination of Fluoxetine in Human Plasma by Liquid Chromatography-Mass Spectrometry and Its Application
    Zhou, Neng
    Chen, Ben-Mei
    Pan, Tong
    Liu, Shaogang
    [J]. ANALYTICAL LETTERS, 2009, 42 (13) : 2071 - 2086
  • [49] Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry
    Antonia Garrido Frenich
    R. Romero-González
    José Luis Martínez Vidal
    R. Martínez Ocaña
    P. Baquero Feria
    [J]. Analytical and Bioanalytical Chemistry, 2011, 399 : 2043 - 2059
  • [50] Hollow fiber liquid-phase microextraction combined with supercritical fluid chromatography coupled to mass spectrometry for multiclass emerging contaminant quantification in water samples
    del Carmen Salvatierra-Stamp, Vilma
    Ceballos-Magana, Silvia G.
    Susana Pano-Farias, Norma
    Belisario Leyva-Morales, Jose
    Pineda-Urbina, Kayim
    Muniz-Valencia, Roberto
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2467 - 2479