Contrast-Enhanced Ultrasound in the Evaluation of Complex Cystic and Solid Breast Masses-A Feasibility Study

被引:1
作者
Shi, Haiyuan [1 ]
Chee, Charlyn Chai Hoon [2 ]
Seng, Angela Peck Ying [2 ]
Koh, Xuan Han [3 ]
Teoh, Wey Chyi [1 ]
Mahmood, Rameysh Danovani [1 ,4 ]
机构
[1] Changi Gen Hosp, Dept Radiol, Singapore, Singapore
[2] Changi Gen Hosp, Dept Radiog, Singapore, Singapore
[3] Changi Gen Hosp, Dept Hlth Serv Res, Singapore, Singapore
[4] Specialist Camden Med, Singapore, Singapore
关键词
complex cystic and solid breast masses; complex breast cysts; contrast-enhanced ultrasound; breast imaging; TUMOR VASCULARITY; DOPPLER; SONOGRAPHY; US;
D O I
10.1093/jbi/wbae007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective Complex cystic and solid breast mass (CCSBM) is a radiological diagnosis based on grayscale B-mode sonographic features. Because of potential for malignancy, biopsy is typically recommended. We examined the feasibility of contrast-enhanced US (CEUS) as a tool to identify benign CCSBMs.Methods This Institutional Review Board-approved prospective observational study performed targeted CEUS of 14 CCSBMs that were subsequently biopsied. CEUS images were independently reviewed by two readers blinded to other sonographic features, noting presence or absence of enhancement and time to perceived optimal enhancement. Interobserver agreement for presence or absence of enhancement was analyzed using Cohen's kappa coefficient. From retrospective review of initial diagnostic US examinations, descriptive CCSBM sizes, subtypes, and Doppler information were recorded. Histopathologies were categorized as benign, benign with upgrade potential (BWUP), and malignant. Measures of diagnostic accuracy and 95% CIs were calculated for CEUS enhancement.Results Of 14 CCSBMs, 12 were nonmalignant (9 benign, 3 BWUP) and 2 were malignant. There was perfect interobserver agreement (Cohen's kappa 1.00) between the 2 readers for CEUS enhancement. CEUS was 100% sensitive, 25% specific, with an area under the receiver operating characteristic curve (AUROC) of 0.625 (95% CI, 0.50-0.75) in differentiating nonmalignant from malignant lesions. It was 100% sensitive, 33.3% specific, with an AUROC of 0.667 (95% CI, 0.50-0.85) in differentiating benign from surgically significant (BWUP and malignant) CCSBMs.Conclusion This small feasibility study highlighted the potential of CEUS as a safe noninvasive tool to identify the proportion of CCSBMs that are benign and can avoid tissue biopsy.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 50 条
  • [1] Early Experience With Contrast-enhanced Ultrasound in the Diagnosis of Testicular Masses: A Feasibility Study
    Lock, Guntram
    Schmidt, Christa
    Helmich, Friederike
    Stolle, Evelyn
    Dieckmann, Klaus-Peter
    UROLOGY, 2011, 77 (05) : 1049 - 1053
  • [2] Diagnostic Performance of Contrast-Enhanced Ultrasound (CEUS) in the Evaluation of Solid Renal Masses
    Geyer, Thomas
    Schwarze, Vincent
    Marschner, Constantin
    Schnitzer, Moritz L.
    Froelich, Matthias F.
    Ruebenthaler, Johannes
    Clevert, Dirk-Andre
    MEDICINA-LITHUANIA, 2020, 56 (11): : 1 - 8
  • [3] Evaluation of Cystic and Solid Renal Lesions with Contrast-Enhanced Ultrasound: A Retrospective Study
    Najafi, Arash
    Wildt, Michael
    Hainc, Nicolin
    Hohmann, Joachim
    ULTRASOUND INTERNATIONAL OPEN, 2021, 07 (01) : E25 - E34
  • [4] Clinical Evaluation of Cystic Renal Masses With Bosniak Classification by Contrast-Enhanced Ultrasound and Contrast-Enhanced Computer Tomography
    Lan, Li
    Yang, Yu
    Xu, Zi-Qiang
    Jin, Xuan-Chen
    Huang, Ka-Te
    Chen, Yu-Xuan
    Yang, Chen-Xing
    Zhou, Man
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (12) : 2845 - 2858
  • [5] Evaluation of Contrast Enhanced Ultrasound for investigation of complex cystic renal masses
    Shahzad, K.
    Simms, M. S.
    Byass, O.
    JOURNAL OF CLINICAL UROLOGY, 2011, 4 (06) : 253 - 258
  • [6] Contrast-enhanced ultrasound for differentiating benign from malignant solid small renal masses: comparison with contrast-enhanced CT
    Wei, Shu-Ping
    Xu, Chao-Li
    Zhang, Qing
    Zhang, Qi-Rui
    Zhao, Yan-E
    Huang, Peng-Fei
    Xie, Ying-Dong
    Zhou, Chang-Sheng
    Tian, Fu-Li
    Yang, Bin
    ABDOMINAL RADIOLOGY, 2017, 42 (08) : 2135 - 2145
  • [7] Evaluation of Renal Masses with Contrast-Enhanced Ultrasound
    Houtzager, S.
    Wijkstra, H.
    de la Rosette, J. J. M. C. H.
    Laguna, M. P.
    CURRENT UROLOGY REPORTS, 2013, 14 (02) : 116 - 123
  • [8] Evaluation of Renal Masses with Contrast-Enhanced Ultrasound
    S. Houtzager
    H. Wijkstra
    J. J. M. C. H. de la Rosette
    M. P. Laguna
    Current Urology Reports, 2013, 14 : 116 - 123
  • [9] Comparison of contrast-enhanced ultrasound with MRI in the diagnosis of complex cystic renal masses: a meta-analysis
    Zhou, Linli
    Tang, Lemin
    Yang, Tao
    Chen, Wei
    ACTA RADIOLOGICA, 2018, 59 (10) : 1254 - 1263
  • [10] Contrast-enhanced ultrasound (CEUS) of cystic and solid renal lesions: a review
    Gulati, Mittul
    King, Kevin G.
    Gill, Inderbir S.
    Pham, Vivian
    Grant, Edward
    Duddalwar, Vinay A.
    ABDOMINAL IMAGING, 2015, 40 (06): : 1982 - 1996