Measurement of cholesterol levels of lipoprotein subclasses in human serum using anion-exchange high-performance liquid chromatography with a linear concentration gradient of sodium perchlorate

被引:0
|
作者
Ito, Riku [1 ]
Manita, Daisuke [1 ,2 ]
Yanai, Hidekatsu [3 ]
Hirowatari, Yuji [1 ,4 ]
机构
[1] Saitama Prefectural Univ, Dept Hlth Sci, Saitama, Japan
[2] TOSOH Corp, Biosci Div, Tokyo, Kanagawa, Japan
[3] Kohnodai Hosp, Natl Ctr Global Hlth & Med, Dept Diabet Endocrinol & Metab, Kodaira, Japan
[4] Saitama Prefectural Univ, Sch Hlth & Social Serv, Dept Hlth Sci, Lab Sci, 820 San-Nomiya, Koshigaya, Saitama 3438540, Japan
关键词
High-density lipoprotein; low-density lipoprotein; lipoprotein subclass; anion-exchange high-performance liquid chromatography; oxidized low-density lipoprotein; LOW-DENSITY-LIPOPROTEIN; CORONARY-HEART-DISEASE; NUCLEAR-MAGNETIC-RESONANCE; INTIMA-MEDIA THICKNESS; COMPONENT ANALYSIS; ARTERY-DISEASE; ION MOBILITY; ASSOCIATION; LDL; IDENTIFICATION;
D O I
10.1177/00045632231179082
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Relationships between the subclasses of high-density lipoprotein (HDL) or low-density lipoprotein (LDL) and the risk of atherosclerotic cardiovascular disease have been studied, and using various methods, such as ultracentrifugation, electrophoresis, and nuclear magnetic resonance, for analysing lipoprotein subclasses. We established a method for HDL and LDL subclasses using anion-exchange high-performance liquid chromatography (AEX-HPLC) with a linear concentration gradient of sodium perchlorate (NaClO4).Method In the AEX-HPLC, the subclasses of HDL and LDL were separated, and detected using a post-column reactor with an enzymatic cholesterol reagent, that contained cholesterol esterase, cholesterol oxidase, and peroxidase as major ingredients. LDL subclasses were divided based on the absolute value of first-derivative chromatogram.Result Three HDL subclasses, HDL-P1, HDL-P2, and HDL-P3, and three LDL subclasses, LDL-P1, LDL-P2, and LDL-P3, were separated by AEX-HPLC, and detected in order. The major components of HDL-P2 and HDL-P3 were HDL3 and HDL2, respectively. The linearity was determined for each lipoprotein subclass. The coefficients of variation of cholesterol concentration of the subclasses for within-day assay (n = 10) and between-day assay (n = 10) ranged between 3.08-8.94% and 4.52-9.97%, respectively. Cholesterol levels in HDL-P1 of diabetic patients were positively correlated with oxidized LDL levels (r = 0.409, p = 0.002). Moreover, cholesterol levels in LDL-P2 and LDL-P3 were positively correlated with oxidized LDL levels (r = 0.393, p = 0.004 and r = 0.561, p < 0.001, respectively).Conclusion AEX-HPLC may be highly suitable as an assay to clinically assess lipoprotein subclasses.
引用
收藏
页码:374 / 385
页数:12
相关论文
共 14 条
  • [1] Innovatively Established Analysis Method for Lipoprotein Profiles Based on High-Performance Anion-Exchange Liquid Chromatography
    Hirowatari, Yuji
    Yoshida, Hiroshi
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2019, 26 (12) : 1027 - 1040
  • [2] An improved anion-exchange high-performance liquid chromatography method for measuring oxidized form of LDLs in human plasma
    Kitano, Soichi
    Higashimoto, Yuichiro
    Harada, Shoji
    Sano, Masaru
    Kurata, Tsunehiko
    Yamaguchi, Yu
    Kunitomo, Masaru
    Haginaka, Jun
    Yamagishi, Sho-ichi
    ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 460 - 466
  • [3] Verification of Low-Density Lipoprotein Cholesterol Levels Measured by Anion-Exchange High-Performance Liquid Chromatography in Comparison with Beta Quantification Reference Measurement Procedure
    Manita, Daisuke
    Yoshida, Hiroshi
    Koyama, Isao
    Nakamura, Masakazu
    Hirowatari, Yuji
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (03) : 654 - 667
  • [4] Comparison of cholesterol levels among lipoprotein fractions separated by anion-exchange high-performance liquid chromatography in periparturient Holstein-Friesian dairy cows
    Takahashi, Tomoya
    Mori, Akihiro
    Oda, Hitomi
    Murayama, Isao
    Kouno, Mitsuhiko
    Sako, Toshinori
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2021, 83 (02) : 260 - 266
  • [5] LDL-3 fraction levels in patients with unstable angina: Assessment by anion-exchange high-performance liquid chromatography
    Ohmori, Reiko
    Momiyama, Yukihiko
    Tanaka, Nobukiyo
    Kato, Ryuichi
    Taniguchi, Hiroaki
    Nakamura, Haruo
    Ohsuzu, Fumitaka
    ATHEROSCLEROSIS, 2009, 203 (01) : 45 - 46
  • [6] A novel and precise method for simultaneous measurement of serum HDL and LDL subfractions and lipoprotein (a) cholesterol by ultracentrifugation and high-performance liquid chromatography
    Dong, Jun
    Guo, Hanbang
    Yang, Ruiyue
    Li, Hongxia
    Wang, Shu
    Zhang, Jiangtao
    Zhou, Weiyan
    Chen, Wenxiang
    CLINICA CHIMICA ACTA, 2012, 413 (13-14) : 1071 - 1076
  • [7] Oxidative status of human low density lipoprotein isolated by anion-exchange high-performance liquid chromatography -: Assessment by total hydroxyoctadecadienoic acid, 7-hydroxycholesterol, and 8-iso-prostaglandin F2α
    Kitano, Soichi
    Yoshida, Yasukazu
    Kawano, Katsumi
    Hibi, Nozomu
    Niki, Etsuo
    ANALYTICA CHIMICA ACTA, 2007, 585 (01) : 86 - 93
  • [8] Meningococcal X polysaccharide quantification by high-performance anion-exchange chromatography using synthetic N-acetylglucosamine-4-phosphate as standard
    Micoli, F.
    Adamo, R.
    Proietti, D.
    Gavini, M.
    Romano, M. R.
    MacLennan, C. A.
    Costantino, P.
    Berti, F.
    ANALYTICAL BIOCHEMISTRY, 2013, 442 (02) : 259 - 261
  • [9] Avalidated method for measurement of serum total, serum free, and salivary cortisol, using high-performance liquid chromatography coupled with high-resolution ESI-TOF mass spectrometry
    Montsko, Gergely
    Tarjanyi, Zita
    Mezosi, Emese
    Kovacs, Gabor L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (9-10) : 2333 - 2341
  • [10] Trace enrichment and characterization of polyphenols in Bistort Rhizoma using weak anion-exchange solid phase extraction and high performance liquid chromatography-quadrupole time-of-flight mass spectrometry
    Wang, Shao-Teng
    Yang, Hua
    Gao, Wen
    Li, Hui-Jun
    Li, Ping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 119 : 91 - 98