Can Shoulder Impairments Be Classified From 3-Dimensional Kinematics Using Inertial Sensors?

被引:1
|
作者
Mazuquin, Bruno [1 ]
Gill, Karl Peter [1 ,2 ]
Monga, Puneet [3 ]
Selfe, James [1 ]
Richards, Jim [4 ]
机构
[1] Manchester Metropolitan Univ, Dept Hlth Profess, Manchester, England
[2] Fairfield Hosp, Dept Physiotherapy, Northern Care Alliance NHS Grp, Bury, England
[3] Wrightington Hosp, Wigan, Lancs, England
[4] Univ Cent Lancashire, Allied Hlth Res Unit, Preston, England
关键词
rotator cuff; discriminant function analysis; surgery; range of motion; MOTION ANALYSIS;
D O I
10.1123/jab.2022-0173
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inertial sensors may help clinicians to assess patients' movement and potentially support clinical decision making. Our aim was to determine whether shoulder range of motion during movement tasks measured using inertial sensors is capable of accurately discriminating between patients with different shoulder problems. Inertial sensors were used to measure 3-dimensional shoulder motion during 6 tasks of 37 patients on the waiting list for shoulder surgery. Discriminant function analysis was used to identify whether the range of motion of different tasks could classify patients with different shoulder problems. The discriminant function analysis could correctly classify 91.9% of patients into one of the 3 diagnostic groups based. The tasks that associated a patient with a particular diagnostic group were the following: subacromial decompression: abduction, rotator cuff repair of tears <_5 cm: flexion and rotator cuff repair of tears >5 cm: combing hair, abduction, and horizontal abduction-adduction. The discriminant function analysis showed that range of motion measured by inertial sensors can correctly classify patients and could be used as a screening tool to support surgery planning.
引用
收藏
页码:264 / 267
页数:4
相关论文
共 50 条
  • [31] Scapular Kinematics in Atraumatic Shoulder Instability 3-D-Examination Using Electromagnetic Sensors
    Schoettker-Koeniger, T.
    Schwaller, A.
    Baeyens, J. -P.
    Cabri, J.
    Taeymans, J.
    MANUELLE THERAPIE, 2007, 11 (04) : 168 - 176
  • [32] Wearable Inertial Sensors Allow for Quantitative Assessment of Shoulder and Elbow Kinematics in a Cadaveric Knee Arthroscopy Model
    Rose, Michael
    Curtze, Carolin
    O'Sullivan, Joseph
    El-Gohary, Mahmoud
    Crawford, Dennis
    Friess, Darin
    Brady, Jacqueline M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (12): : 2110 - 2116
  • [33] Optimization of glenoid fixation in reverse shoulder arthroplasty using 3-dimensional modeling
    Sutton, Levi G.
    Werner, Frederick W.
    Jones, Alyssa K.
    Close, Christopher A.
    Nanavati, Vipul N.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (05) : 664 - 669
  • [34] ESTIMATION OF 3-DIMENSIONAL JOINT ANGLES USING QUALYSIS POSITION SENSORS
    BARNETT, TG
    LOGAN, JG
    PATERSON, JM
    JOURNAL OF PHYSIOLOGY-LONDON, 1993, 467 : P7 - P7
  • [35] 3-DIMENSIONAL GEOMETRY AND KINEMATICS OF EXPERIMENTAL PIGGYBACK THRUSTING
    MULUGETA, G
    KOYI, H
    GEOLOGY, 1987, 15 (11) : 1052 - 1056
  • [36] The Effect of Lunate Morphology on the 3-Dimensional Kinematics of the Carpus
    Bain, Gregory I.
    Clitherow, Harry D. S.
    Millar, Stuart
    Fraysse, Francois
    Costi, John J.
    Eng, Kevin
    McGuire, Duncan T.
    Thewlis, Dominic
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01): : 81 - U294
  • [37] Effects of muscle fatigue on 3-dimensional scapular kinematics
    Tsai, NT
    McClure, PW
    Karduna, AR
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (07): : 1000 - 1005
  • [38] GENERAL 3-DIMENSIONAL SUPERLUMINAL TRANSFORMATIONS AND TACHYON KINEMATICS
    ANTIPPA, AF
    PHYSICAL REVIEW D, 1975, 11 (04): : 724 - 739
  • [39] SURFACE-STRUCTURE AND 3-DIMENSIONAL MOTION FROM IMAGE FLOW KINEMATICS
    WAXMAN, AM
    ULLMAN, S
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 1985, 4 (03): : 72 - 94
  • [40] A 3-DIMENSIONAL APPROACH TO ASSESSMENT TO INFANT CRAWLING KINEMATICS
    RODGERS, MM
    MUCINO, VH
    YANG, KH
    HARRIS, MB
    JOURNAL OF BIOMECHANICS, 1987, 20 (09) : 910 - 910