Quantification of liver-Lung shunt fraction on 3D SPECT/CT images for selective internal radiation therapy of liver cancer using CNN-based segmentations and non-rigid registration

被引:4
作者
Luu, Manh Ha [1 ,2 ,3 ]
Mai, Hong Son [4 ]
Pham, Xuan Loc [2 ]
Le, Quoc Anh [1 ]
Le, Quoc Khanh [4 ]
van Walsum, Theo [3 ]
Le, Ngoc Ha [4 ]
Franklin, Daniel [5 ]
Le, Vu Ha [1 ,2 ]
Moelker, Adriaan [3 ]
Chu, Duc Trinh [2 ]
Trung, Nguyen Linh [1 ]
机构
[1] VNU Univ Engn & Technol, AVITECH, Hanoi, Vietnam
[2] VNU Univ Engn & Technol, FET, Hanoi, Vietnam
[3] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[4] Hosp 108, Dept Nucl Med, Hanoi, Vietnam
[5] Univ Technol Sydney, Sch Elect & Data Engn, Sydney, Australia
关键词
Liver-lung shunt; Liver cancer; SPECT; CT; CNNs; Segmentation; Registration; HEPATOCELLULAR-CARCINOMA; Y-90; MICROSPHERES; RADIOEMBOLIZATION;
D O I
10.1016/j.cmpb.2023.107453
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Purpose: Selective internal radiation therapy (SIRT) has been proven to be an effective treatment for hepatocellular carcinoma (HCC) patients. In clinical practice, the treatment planning for SIRT using 90Y microspheres requires estimation of the liver-lung shunt fraction (LSF) to avoid radiation pneumonitis. Currently, the manual segmentation method to draw a region of interest (ROI) of the liver and lung in 2D planar imaging of 99mTc-MAA and 3D SPECT/CT images is inconvenient, time-consuming and observer-dependent. In this study, we propose and evaluate a nearly automatic method for LSF quantification using 3D SPECT/CT images, offering im proved performance compared with the current manual segmentation method. Methods: We retrospectively acquired 3D SPECT with non-contrast-enhanced CT images (nCECT) of 60 HCC patients from a SPECT/CT scanning machine, along with the corresponding diagnostic contrast-enhanced CT images (CECT). Our approach for LSF quantification is to use CNN-based methods for liver and lung segmentations in the nCECT image. We first apply 3D ResUnet to coarsely segment the liver. If the liver segmentation contains a large error, we dilate the coarse liver segmentation into the liver mask as a ROI in the nCECT image. Subsequently, non-rigid registration is applied to deform the liver in the CECT image to fit that obtained in the nCECT image. The final liver segmentation is obtained by segmenting the liver in the deformed CECT image using nnU-Net. In addition, the lung segmentations are obtained using 2D ResUnet. Finally, LSF quantitation is performed based on the number of counts in the SPECT image inside the segmentations. Evaluations and Results: To evaluate the liver segmentation accuracy, we used Dice similarity coefficient (DSC), asymmetric surface distance (ASSD), and max surface distance (MSD) and compared the proposed method to five well-known CNN-based methods for liver segmentation. Furthermore, the LSF error ob-tained by the proposed method was compared to a state-of-the-art method, modified Deepmedic, and the LSF quantifications obtained by manual segmentation. The results show that the proposed method achieved a DSC score for the liver segmentation that is comparable to other state-of-the-art methods, with an average of 0.93, and the highest consistency in segmentation accuracy, yielding a standard devia-tion of the DSC score of 0.01. The proposed method also obtains the lowest ASSD and MSD scores on aver-age (2.6 mm and 31.5 mm, respectively). Moreover, for the proposed method, a median LSF error of 0.14% is obtained, which is a statically significant improvement to the state-of-the-art-method (p = 0. 004 ), and is much smaller than the median error in LSF manual determination by the medical experts using 2D planar image (1.74% and p < 0. 001 ). Conclusions: A method for LSF quantification using 3D SPECT/CT images based on CNNs and non-rigid registration was proposed, evaluated and compared to state-of-the-art techniques. The proposed method can quantitatively determine the LSF with high accuracy and has the potential to be applied in clinical practice. (c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 42 条
  • [11] A unified approach to fast image registration and a new curvature based registration technique
    Fischer, B
    Modersitzki, J
    [J]. LINEAR ALGEBRA AND ITS APPLICATIONS, 2004, 380 : 107 - 124
  • [12] A review of deep learning based methods for medical image multi-organ segmentation
    Fu, Yabo
    Lei, Yang
    Wang, Tonghe
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 107 - 122
  • [13] Deep learning in medical image registration: a review
    Fu, Yabo
    Lei, Yang
    Wang, Tonghe
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (20)
  • [14] Lung shunt fraction calculation using 99mTc-MAA SPECT/CT imaging for 90Y microsphere selective internal radiation therapy of liver tumors
    Georgiou, Mike F.
    Kuker, Russ A.
    Studenski, Matthew T.
    Ahlman, Preeti P.
    Witte, Megan
    Portelance, Lorraine
    [J]. EJNMMI RESEARCH, 2021, 11 (01)
  • [15] Prognostic factors and prevention of radioembolization-induced liver disease
    Gil-Alzugaray, Belen
    Chopitea, Ana
    Inarrairaegui, Mercedes
    Bilbao, Jose I.
    Rodriguez-Fraile, Macarena
    Rodriguez, Javier
    Benito, Alberto
    Dominguez, Ines
    D'Avola, Delia
    Herrero, Jose I.
    Quiroga, Jorge
    Prieto, Jesus
    Sangro, Bruno
    [J]. HEPATOLOGY, 2013, 57 (03) : 1078 - 1087
  • [16] Comparison and Evaluation of Methods for Liver Segmentation From CT Datasets
    Heimann, Tobias
    van Ginneken, Bram
    Styner, Martin A.
    Arzhaeva, Yulia
    Aurich, Volker
    Bauer, Christian
    Beck, Andreas
    Becker, Christoph
    Beichel, Reinhard
    Bekes, Gyoergy
    Bello, Fernando
    Binnig, Gerd
    Bischof, Horst
    Bornik, Alexander
    Cashman, Peter M. M.
    Chi, Ying
    Cordova, Andres
    Dawant, Benoit M.
    Fidrich, Marta
    Furst, Jacob D.
    Furukawa, Daisuke
    Grenacher, Lars
    Hornegger, Joachim
    Kainmueller, Dagmar
    Kitney, Richard I.
    Kobatake, Hidefumi
    Lamecker, Hans
    Lange, Thomas
    Lee, Jeongjin
    Lennon, Brian
    Li, Rui
    Li, Senhu
    Meinzer, Hans-Peter
    Nemeth, Gabor
    Raicu, Daniela S.
    Rau, Anne-Mareike
    van Rikxoort, Eva M.
    Rousson, Mikael
    Rusko, Laszlo
    Saddi, Kinda A.
    Schmidt, Guenter
    Seghers, Dieter
    Shimizu, Akinobu
    Slagmolen, Pieter
    Sorantin, Erich
    Soza, Grzegorz
    Susomboon, Ruchaneewan
    Waite, Jonathan M.
    Wimmer, Andreas
    Wolf, Ivo
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (08) : 1251 - 1265
  • [17] Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer
    S. Ho
    W. Y. Lau
    T. W. T. Leung
    M. Chan
    P. J. Johnson
    A. K. C. Li
    [J]. European Journal of Nuclear Medicine, 1997, 24 (3) : 293 - 298
  • [18] Automatic lung segmentation in routine imaging is primarily a data diversity problem, not a methodology problem
    Hofmanninger, Johannes
    Prayer, Forian
    Pan, Jeanny
    Roehrich, Sebastian
    Prosch, Helmut
    Langs, Georg
    [J]. EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [19] Hoang HS, 2019, ISCIT 2019: PROCEEDINGS OF 2019 19TH INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES (ISCIT), P20, DOI 10.1109/ISCIT.2019.8905166
  • [20] nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
    Isensee, Fabian
    Jaeger, Paul F.
    Kohl, Simon A. A.
    Petersen, Jens
    Maier-Hein, Klaus H.
    [J]. NATURE METHODS, 2021, 18 (02) : 203 - +