Comparison of biometry measurements and intraocular lens power prediction between 2 SS-OCT-based biometers

被引:9
作者
Sorkin, Nir [1 ,2 ]
Zadok, Tal [3 ]
Barrett, Graham D. [4 ,5 ]
Chasid, Otzem [3 ,6 ]
Abulafia, Adi [7 ,8 ]
机构
[1] Tel Aviv Med Ctr & Sch Med, Dept Ophthalmol, Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
[3] Bar Ilan Univ, Azrieli Fac Med, Safed, Israel
[4] Univ Western Australia, Sir Charles Gairdner Hosp, Perth, WA, Australia
[5] Univ Western Australia, Lions Eye Inst, Perth, WA, Australia
[6] Ziv Med Ctr, Dept Ophthalmol, Safed, Israel
[7] Shaare Zedek Med Ctr, Dept Ophthalmol, Jerusalem, Israel
[8] Hebrew Univ Jerusalem, Hadassah Med Sch, Jerusalem, Israel
关键词
POSTERIOR CORNEAL ASTIGMATISM; SOURCE OPTICAL COHERENCE; KERATOMETRY; AGREEMENT; TOMOGRAPHY; ACCURACY;
D O I
10.1097/j.jcrs.0000000000001146
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the agreement in biometry measurements and intraocular lens (IOL) power prediction between the Eyestar 900 and the IOLMaster 700. Setting: Institutional. Design: Retrospective comparative study. Methods: Patients were evaluated before cataract surgery using both devices on the same visit. Axial length, anterior and posterior keratometry, anterior chamber depth, corneal diameter (CD), central corneal thickness, and lens thickness were recorded by both devices. The agreement in measurements and in IOL power calculations was evaluated using the Barrett Universal II (BU-II) formula with either predicted or measured posterior keratometry. Results: In total, 402 eyes of 402 consecutive patients were included. The mean age was 72.0 +/- 9.2 years. Clinically, mean differences in measured variables were small, albeit slightly larger for posterior flat and steep keratometry (0.43 diopters [D] and 0.42 D, respectively). The measurement correlation and agreement between the devices were good for all variables with slightly lower agreement in CD measurements. Consistent bias was seen in measurements of posterior flat and steep keratometry. Good agreement was also found in anterior and posterior astigmatism measurements. Good IOL power calculation agreement was found using either predicted posterior keratometry (95% limits of agreement [LoA] of -0.40 to +0.30 D) or measured posterior keratometry (95% LoA of -0.45 to +0.40 D). The agreement was within +/- 0.5 D in 394 eyes (98.0%) using predicted posterior keratometry and in 386 eyes (96.0%) using measured posterior keratometry. Conclusions: The Eyestar 900 and the IOLMaster 700 show strong agreement in biometry measurements and IOL power prediction by the BU-II formula using either standard or total corneal keratometry and can be used interchangeably. Copyright (c) 2023 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:460 / 466
页数:7
相关论文
共 21 条
[1]   Measured Corneal Astigmatism Versus Pseudophakic Predicted Refractive Astigmatism in Cataract Surgery Candidates [J].
Abulafia, Adi ;
Barrett, Grahama D. ;
Porat-Rein, Adi ;
Tsessler, Maria ;
Zadok, David ;
Kan-Tor, Yoav ;
Mourits, Maarten P. ;
Lapid-Gortzak, Ruth .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 240 :225-231
[2]   Comparison of Methods to Predict Residual Astigmatism After Intraocular Lens Implantation [J].
Abulafia, Adi ;
Hill, Warren E. ;
Franchina, Maria ;
Barrett, Graham D. .
JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (10) :699-+
[3]   Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500 [J].
Akman, Ahmet ;
Asena, Leyla ;
Gungor, Sirel Gur .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) :1201-1205
[4]   Statistical guidelines for the analysis of data obtained from one or both eyes [J].
Armstrong, Richard A. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (01) :7-14
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas [J].
Fabian, Ekkehard ;
Wehner, Wolfram .
JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (06) :362-369
[7]   Repeatability of new optical biometer and agreement with 2 validated optical biometers, all based on SS-OCT [J].
Galzignato, Alice ;
Lupardi, Enrico ;
Hoffer, Kenneth J. ;
Barboni, Piero ;
Schiano-Lomoriello, Domenico ;
Savini, Giacomo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (01) :5-10
[8]   Astigmatism analysis and reporting of surgically induced astigmatism and prediction error [J].
Holladay, Jack T. ;
Wilcox, Rand R. ;
Koch, Douglas D. ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (07) :799-812
[9]   Contribution of posterior corneal astigmatism to total corneal astigmatism [J].
Koch, Douglas D. ;
Ali, Shazia F. ;
Weikert, Mitchell P. ;
Shirayama, Mariko ;
Jenkins, Richard ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) :2080-2087
[10]   Agreement between swept-source optical biometry and Scheimpflug-based topography measurements of posterior corneal curvature [J].
Kose, Bulent .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02) :185-189