共 50 条
Exposure to metals among Electronic Nicotine Delivery System (ENDS) users in the PATH study: A longitudinal analysis
被引:3
|作者:
Kaplan, Bekir
[1
,4
]
Navas-Acien, Ana
[2
]
Rule, Ana M.
[3
]
Hilpert, Markus
[2
]
Cohen, Joanna E.
[1
]
机构:
[1] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Inst Global Tobacco Control, Dept Hlth Behav & Soc, Baltimore, MD USA
[2] Columbia Univ, Mailman Sch Publ Hlth, Dept Environm Hlth Sci, New York, NY USA
[3] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Environm Hlth & Engn, Baltimore, MD USA
[4] 2213 McElderry St Fourth Floor, Baltimore, MD 21205 USA
基金:
美国国家卫生研究院;
关键词:
E-cigarettes;
Metal;
Urine;
E-CIGARETTE USE;
CADMIUM EXPOSURE;
NATIONAL-HEALTH;
UNITED-STATES;
ASSOCIATION;
MORTALITY;
URINE;
RISK;
LEAD;
D O I:
10.1016/j.envres.2023.116032
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
Background: Few studies have evaluated Electronic Nicotine Delivery Systems (ENDS) in longitudinal studies, as a potential source of metals which may have carcinogenic, neurotoxic, and cardiotoxic effects. We evaluated metal body burden by ENDS use status in a longitudinal population-based national survey.Methods: We used the Population Assessment of Tobacco and Health (PATH) Study wave 1 (2013-2014), wave 2 (2014-2015), and wave 3 (2015-2016) adult data to assess urinary concentrations of seven metals among (1) ENDS only users who never used any nonelectronic tobacco products (n = 50), (2) ENDS only users who were former users of any nonelectronic tobacco products (n = 123) and (3) Never users (n = 1501) of any tobacco product.Results: Among ENDS only users who never used any nonelectronic tobacco products (n = 50), the geometric mean ratios (GMRs) of Cd and Pb were 1.25 (95%CI: 1.09-1.42) and 1.19 (95%CI: 1.05-1.34), respectively, compared to never users after adjustment for PATH Study wave, age, sex, race/ethnicity, education, region, secondhand smoke at home and work, and cannabis and other substance use. After the same adjustment, the corresponding GMRs were 1.48 (95%CI: 1.32-1.67) and 1.43 (95%CI: 1.28-1.60) for ENDS only users who were former users of any nonelectronic tobacco products (n = 123). No difference was observed in urinary concentrations of other metals comparing ENDS users to never users of any tobacco product. Discussion: ENDS users show higher urinary levels of Cd and Pb, including lifetime exclusive ENDS users compared to never users of any tobacco product. These findings are limited by the small sample size and could be related to underreporting of past combustible tobacco use or other factors. Metals typical of ENDS such as nickel and chromium unfortunately are not available in PATH. Studies assessing metal exposure associated with long term lifetime exclusive ENDS use (>= 5 years) with larger sample size are needed.
引用
收藏
页数:7
相关论文