BMI-Based organ doses in endovascular aneurysm repair interventions utilising Monte Carlo simulation

被引:2
作者
Efthymiou, Fotios O. [1 ]
Metaxas, Vasileios I. [1 ]
Dimitroukas, Christos P. [1 ,2 ]
Kakkos, Stavros K. [2 ]
Moulakakis, Konstantinos G. [3 ]
Belavgenis, Andreas C. [1 ]
Panayiotakis, George S. [1 ,2 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26504, Greece
[2] Univ Hosp Patras, Dept Med Phys, Patras 26504, Greece
[3] Univ Patras, Sch Med, Dept Vasc Surg, Patras 26504, Greece
关键词
Organ dose; Body mass index; Endovascular aneurysm repair; Monte Carlo; RADIATION-EXPOSURE; RISK; TOOL;
D O I
10.1016/j.apradiso.2023.110740
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the effect of body-mass-index (BMI) on organ doses (ODs) during infrarenal endovascular-aneurysm-repair (EVAR) procedures was evaluated. Patient-and intra-operative data from fifty-nine EVAR procedures were inserted into VirtualDose-IR software to calculate ODs. For overweight, obesity class-I and obesity class-II, ODs were up to 147%, 412% and 775% higher than those for normal weight-patients, respec-tively. A large variation was observed in ODs published in literature mainly due to the differences in the software and the technical parameters used for the calculations.
引用
收藏
页数:7
相关论文
共 26 条
[1]   Patterns of procedure-specific radiation exposure in the endovascular era: Impetus for further innovation [J].
Bannazadeh, Mohsen ;
Altinel, Ozcan ;
Kashyap, Vikram S. ;
Sun, Zhiyuan ;
Clair, Daniel ;
Sarac, Timur P. .
JOURNAL OF VASCULAR SURGERY, 2009, 49 (06) :1520-1524
[2]   Monte Carlo Simulations for Assessment of Organ Radiation Doses and Cancer Risk in Patients Undergoing Abdominal Stent-graft Implantation [J].
Blaszak, M. A. ;
Juszkat, R. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (01) :23-28
[3]  
Budtz-Lilly J., 2017, EUR
[4]   Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography [J].
Deak, Paul ;
van Straten, Marcel ;
Shrimpton, Paul C. ;
Zankl, Maria ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (04) :759-772
[5]   KERMA-AREA PRODUCT, ENTRANCE SURFACE DOSE AND EFFECTIVE DOSE IN ABDOMINAL ENDOVASCULAR ANEURYSM REPAIR [J].
Efthymiou, Fotios O. ;
Metaxas, Vasileios, I ;
Dimitroukas, Christos P. ;
Kakkos, Stavros K. ;
Panayiotakis, George S. .
RADIATION PROTECTION DOSIMETRY, 2021, 194 (2-3) :121-134
[6]   Effective-dose estimation in interventional radiological procedures [J].
Falco M.D. ;
Masala S. ;
Stefanini M. ;
Bagalà P. ;
Morosetti D. ;
Calabria E. ;
Tonnetti A. ;
Verona-Rinati G. .
Radiological Physics and Technology, 2018, 11 (2) :149-155
[7]   Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom [J].
Foerth, Monika ;
Seidenbusch, Michael C. ;
Sadeghi-Azandaryani, Mojtaba ;
Lechel, Ursula ;
Treitl, Karla Maria ;
Treitl, Marcus .
EUROPEAN RADIOLOGY, 2015, 25 (09) :2617-2626
[8]   The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair [J].
Fossaceca, Rita ;
Brambilla, Marco ;
Guzzardi, Giuseppe ;
Cerini, Paolo ;
Renghi, Alessandra ;
Valzano, Serena ;
Brustia, Piero ;
Carriero, Alessandro .
EUROPEAN RADIOLOGY, 2012, 22 (11) :2424-2431
[9]   Patient radiation dose from x-ray guided endovascular aneurysm repair: a Monte Carlo approach using voxel phantoms and detailed exposure information [J].
Harbron, Richard W. ;
Abdelhalim, Mohamed ;
Ainsbury, Elizabeth A. ;
Eakins, Jonathan S. ;
Alam, Azeem ;
Lee, Choonsik ;
Modarai, Bijan .
JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (03) :704-726
[10]   VirtualDose-IR: a cloud-based software for reporting organ doses in interventional radiology [J].
Huo, Wanli ;
Pi, Yifei ;
Feng, Mang ;
Qi, Yaping ;
Gao, Yiming ;
Caracappa, Peter F. ;
Chen, Zhi ;
Xu, X. George .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09)