Volatile Organic Compound Identification-Based Tuberculosis Screening among TB Suspects: A Diagnostic Accuracy Study

被引:5
作者
Badola, Mayank [1 ]
Agrawal, Anurag [2 ]
Roy, Debabrata [3 ]
Sinha, Richa [3 ]
Goyal, Avisham [2 ]
Jeet, Narayan [4 ]
机构
[1] Govt Uttarakhand, Dept Hlth & Family Welf, Dehra Dun 248001, India
[2] Govt Doon Med Coll, Dept TB & Chest, Dehra Dun 248001, India
[3] Govt Doon Med Coll, Dept Community Med, Dehra Dun 248001, India
[4] Govt Doon Med Coll, Dept Gen Med, Dehra Dun 248001, India
关键词
VOCs; diagnostic accuracy study; breath testing; Mycobacterium tuberculosis; PULMONARY TUBERCULOSIS; BIOMARKERS;
D O I
10.3390/arm91040024
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Highlights What are the main findings? The test kit showed significantly high sensitivity and specificity as reliability indicators for a potential non-invasive, rapid, cost-effective technique that uses the volatile biomarkers in exhaled breath for the identification of tuberculosis. Volatile organic compounds are evidently strong contenders for being potential tuberculosis biomarkers. What is the implications of the main findings? The diagnostic accuracy of the Tuberculosis Breath Analyzer was found to be high for TB detection. The performance of the tested Tuberculosis Breath Analyzer was found to be comparable in efficiency to that of the TrueNat assay.Highlights What are the main findings? The test kit showed significantly high sensitivity and specificity as reliability indicators for a potential non-invasive, rapid, cost-effective technique that uses the volatile biomarkers in exhaled breath for the identification of tuberculosis. Volatile organic compounds are evidently strong contenders for being potential tuberculosis biomarkers. What is the implications of the main findings? The diagnostic accuracy of the Tuberculosis Breath Analyzer was found to be high for TB detection. The performance of the tested Tuberculosis Breath Analyzer was found to be comparable in efficiency to that of the TrueNat assay.Abstract Tuberculosis (TB) affects a third of the global population, and a large population of infected individuals still remain undiagnosed-making the visible burden only the tip of the iceberg. The detection of tuberculosis in close-proximity patients is one of the key priorities for attaining the Sustainable Development Goals (SDG) of TB elimination by 2030. With the current battery of screening tests failing to cover this need, the authors of this paper examined a simple and inexpensive point-of-care breath analyzer (TSI-3000(I)), which is based on detecting the volatile organic compounds that are emitted from infected cells and released in exhaled breath as a screening tool for the detection of TB. A single-center pilot study for assessing the diagnostic accuracy of the point-of-care Tuberculosis Breath Analyzer was conducted, and it was compared against the WHO-recommended TrueNat assay, which is a rapid molecular test and was also treated as the reference standard in this study. Of the 334 enrolled participants with TB signs/symptoms, 42.51% were TrueNat positive for Mycobacterium tuberculosis. The sensitivity of the Tuberculosis Breath Analyzer was found to be 95.7%, with a specificity of 91.3% and a ROC area of 0.935. The test kit showed considerable/significant high sensitivity and specificity as reliability indicators. The performance of the Tuberculosis Breath Analyzer tested was found to be comparable in efficiency to that of the TrueNat assay. A large cohort-based multicentric study is feasibly required to further validate and extrapolate the results of the pilot study.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 27 条
[1]   Noninvasive detection of lung cancer by analysis of exhaled breath [J].
Bajtarevic, Amel ;
Ager, Clemens ;
Pienz, Martin ;
Klieber, Martin ;
Schwarz, Konrad ;
Ligor, Magdalena ;
Ligor, Tomasz ;
Filipiak, Wojciech ;
Denz, Hubert ;
Fiegl, Michael ;
Hilbe, Wolfgang ;
Weiss, Wolfgang ;
Lukas, Peter ;
Jamnig, Herbert ;
Hackl, Martin ;
Haidenberger, Alfred ;
Buszewski, Boguslaw ;
Miekisch, Wolfram ;
Schubert, Jochen ;
Amann, Anton .
BMC CANCER, 2009, 9 :348
[2]   Exhaled human breath analysis in active pulmonary tuberculosis diagnostics by comprehensive gas chromatography-mass spectrometry and chemometric techniques [J].
Beccaria, Marco ;
Bobak, Carly ;
Maitshotlo, Boitumelo ;
Mellors, Theodore R. ;
Purcaro, Giorgia ;
Franchina, Flavio A. ;
Rees, Christiaan A. ;
Nasir, Mavra ;
Black, Andrew ;
Hill, Jane E. .
JOURNAL OF BREATH RESEARCH, 2019, 13 (01)
[3]   Diagnosis - Comparative accuracy: assessing new tests against existing diagnostic pathways [J].
Bossuyt, PM ;
Irwig, L ;
Craig, J ;
Glasziou, P .
BRITISH MEDICAL JOURNAL, 2006, 332 (7549) :1089-1092
[4]   Human exhaled air analytics: Biomarkers of diseases [J].
Buszewski, Boguslaw ;
Kesy, Martyna ;
Ligor, Tomasz ;
Amann, Anton .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) :553-566
[5]  
Central TB Division Directorate General of Health Services Ministry of Health and Famly Welfare Government of India, NAT STRAT PLAN TUB E
[6]  
Engbaek K, 2003, Manual of basic techniques for a health laboratory
[7]   Magnitude and Reasons for Gaps in Tuberculosis Diagnostic Testing and Treatment Initiation: An Operational Research Study from Dakshina Kannada, South India [J].
Ismail, Imaad Mohammed ;
Madhukeshwar, Akshaya Kibballi ;
Naik, Poonam Ramesh ;
Nayarmoole, Badarudeen Mohammad ;
Satyanarayana, Srinath .
JOURNAL OF EPIDEMIOLOGY AND GLOBAL HEALTH, 2020, 10 (04) :326-336
[8]  
MacPherson P, 2021, WHO consolidated guidelines on tuberculosis module 2: screening-systematic screening for tuberculosis disease
[9]  
Ministry of Health & Family Welfare-Government of India, 2016, REV NAT TB CONTR PRO
[10]  
Ministry of Health & Family Welfare-Government of India, 2021, IND TB REP