Accuracy of Intraocular Lens Power Calculation in Pediatric Secondary Implantation: In-the-Bag Versus Sulcus Placement

被引:3
作者
Liu, Zhenzhen [1 ,2 ,3 ,4 ]
Zou, Yingshi [2 ,3 ,4 ]
Yu, Yinglin [2 ,3 ,4 ]
Qu, Bo [2 ,3 ,4 ]
Jin, Ling [2 ,3 ,4 ]
Tan, Yuan [2 ,3 ,4 ]
Chen, Hui [2 ,3 ,4 ]
Xu, Jingmin [2 ,3 ,4 ]
Lin, Zhuoling [2 ,3 ,4 ]
Li, Jing [2 ,3 ,4 ]
Liu, Jianping [2 ,3 ,4 ]
Luo, Lixia [2 ,3 ,4 ]
Chen, Weirong [2 ,3 ,4 ]
Liu, Yizhi [1 ,2 ,3 ,4 ]
机构
[1] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
[3] Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Guangdong, Peoples R China
[4] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
REFRACTIVE OUTCOMES; IOL; COMPLICATIONS; CHALLENGES; CHILDREN; APHAKIA;
D O I
10.1016/j.ajo.2022.12.028
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To compare the effects of secondary in-the- bag vs ciliary sulcus intraocular lens (IOL) implantation on the accuracy of IOL power calculation in pediatric eyes.center dot DESIGN: Prospective nonrandomized interventional study.center dot METHODS: Pediatric aphakic eyes that underwent ei- ther in-the-bag or ciliary sulcus secondary IOL implan- tation were included. The mean prediction error (PE), mean absolute error (MAE), median absolute error, and percentages of eyes with PE within +/- 0.25 diopter (D), +/- 0.50 D, +/- 0.75 D, and +/- 1.00 D were calculated and compared using SRK/T formula.center dot RESULTS: One hundred fourteen eyes (38.26%) re- ceived in-the-bag IOL implantation and 184 (61.74%) underwent ciliary sulcus IOL implantation. Compared with the sulcus group, the capsular group displayed signif- icantly lower MAE and higher percentage of eyes within +/- 0.50 D of PE (MAE: 0.90 vs 1.56 D; +/- 0.50 D: 40.40% vs 14.29%, both P <.001). The eyes receiv- ing in-the-bag IOL implantation (sulcus IOL implanta- tion fi: -1.060, 95% CI:-1.415 to-0.705; P <.001), unilateral ( fi: 0.647, 95% CI: 0.144-1.150; P=.012), or with deeper anterior chamber depth ( fi: 0.362, 95% CI: 0.068-0.656; P=.016) were prone to maintain hy- peropia (PE > 0). To reduce PE, when the predicted cap- sular IOL power was between 11.50 and 30.00 D, the power of a sulcus-implanted IOL should be reduced by 0.50 to 2.50 D accordingly (the exact amount of reduc- tion is positively related to the predicted power).center dot CONCLUSIONS: In-the-bag implantation yielded smaller PE in pediatric eyes undergoing secondary IOL implan- tation. Adjustment of IOL power for ciliary sulcus im- plantation is required to reduce PE, and the amount of adjustment is positively correlated with the IOL power predicted by SRK/T formula. (Am J Ophthal- mol 2023;249: 137-143.(c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
[31]   Intraocular lens implantation as an isolated risk factor for secondary glaucoma in pediatric patients [J].
Yagev, Ronit ;
Khatib, Nur ;
Barrett, Chiya ;
Yotam, Lior ;
Lifshitz, Tova ;
Tsumi, Erez .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2019, 54 (05) :621-625
[32]   Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients [J].
An-Nakhli, Fouad Raja .
TAIWAN JOURNAL OF OPHTHALMOLOGY, 2019, 9 (01) :37-42
[33]   Accuracy of Intraocular Lens Power Calculation Formulas in Pediatric Cataract Patients: A Systematic Review and Meta-Analysis [J].
Zhong, Yueyang ;
Yu, Yibo ;
Li, Jinyu ;
Lu, Bing ;
Li, Su ;
Zhu, Yanan .
FRONTIERS IN MEDICINE, 2021, 8
[34]   Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes [J].
Li, Xinxin ;
Song, Chunyuan ;
Wang, Yong ;
Wang, Jing ;
Tang, Qiongyan ;
Wu, Zheming ;
Zhou, Yanwen ;
Sun, Juan ;
Jia, Yanhong ;
Lin, Zhenlin ;
Li, Shaowei .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (11) :3619-3628
[35]   Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema [J].
Shemer, Asaf ;
Fradkin, Maayan ;
Dubinsky-Pertzov, Biana ;
Reitblat, Olga ;
Simaan, Francis ;
Sella, Ruti ;
Pras, Eran ;
Einan-Lifshitz, Adi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2025, 51 (02) :141-146
[36]   Accuracy of Intraocular Lens Power Calculation in Microspherophakia Patients: Comparison of 7 Formulas [J].
Sun, Yang ;
Chen, Tianhui ;
Chen, Zexu ;
Jia, Wannan ;
Zhao, Zhennan ;
Jiang, Yongxiang .
OPHTHALMIC RESEARCH, 2025, 68 (01) :237-251
[37]   Accuracy of intraocular lens power calculation formulae for the Yamane technique of secondary fixation: a systematic review and meta-analysis [J].
Khowaja, Aly Hamza ;
Ghazanfar, Altamash Shahriyar ;
Tayyab, Haroon .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025, 263 (02) :259-268
[38]   Cataract Management in Juvenile Idiopathic Arthritis: Simultaneous versus Secondary Intraocular Lens Implantation [J].
Magli, Adriano ;
Forte, Raimondo ;
Rombetto, Luca ;
Alessio, Maria .
OCULAR IMMUNOLOGY AND INFLAMMATION, 2014, 22 (02) :133-137
[39]   Secondary intraocular lens implantation with absence of capsular support: Scleral versus iris fixation [J].
Nehme, J. ;
Sahyoun, M. ;
Saad, M. ;
Slim, E. ;
Farhat, R. ;
Azar, G. ;
Jalkh, A. ;
Sannaha, A. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2018, 41 (07) :630-636
[40]   Complications, Visual Acuity, and Refractive Error 3 Years after Secondary Intraocular Lens Implantation for Pediatric Aphakia [J].
Wang, Serena ;
Repka, Michael X. ;
Sutherland, Desirae R. ;
Hatt, Sarah R. ;
Traboulsi, Elias I. ;
Lambert, Scott R. ;
Melia, B. Michele ;
Kraker, Raymond T. ;
Holmes, Jonathan M. ;
Cotter, Susan A. .
OPHTHALMOLOGY, 2024, 131 (10) :1196-1206