Accuracy of Intraocular Lens Power Calculation in Pediatric Secondary Implantation: In-the-Bag Versus Sulcus Placement

被引:1
作者
Liu, Zhenzhen [1 ,2 ,3 ,4 ]
Zou, Yingshi [2 ,3 ,4 ]
Yu, Yinglin [2 ,3 ,4 ]
Qu, Bo [2 ,3 ,4 ]
Jin, Ling [2 ,3 ,4 ]
Tan, Yuan [2 ,3 ,4 ]
Chen, Hui [2 ,3 ,4 ]
Xu, Jingmin [2 ,3 ,4 ]
Lin, Zhuoling [2 ,3 ,4 ]
Li, Jing [2 ,3 ,4 ]
Liu, Jianping [2 ,3 ,4 ]
Luo, Lixia [2 ,3 ,4 ]
Chen, Weirong [2 ,3 ,4 ]
Liu, Yizhi [1 ,2 ,3 ,4 ]
机构
[1] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
[3] Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Guangdong, Peoples R China
[4] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
REFRACTIVE OUTCOMES; IOL; COMPLICATIONS; CHALLENGES; CHILDREN; APHAKIA;
D O I
10.1016/j.ajo.2022.12.028
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To compare the effects of secondary in-the- bag vs ciliary sulcus intraocular lens (IOL) implantation on the accuracy of IOL power calculation in pediatric eyes.center dot DESIGN: Prospective nonrandomized interventional study.center dot METHODS: Pediatric aphakic eyes that underwent ei- ther in-the-bag or ciliary sulcus secondary IOL implan- tation were included. The mean prediction error (PE), mean absolute error (MAE), median absolute error, and percentages of eyes with PE within +/- 0.25 diopter (D), +/- 0.50 D, +/- 0.75 D, and +/- 1.00 D were calculated and compared using SRK/T formula.center dot RESULTS: One hundred fourteen eyes (38.26%) re- ceived in-the-bag IOL implantation and 184 (61.74%) underwent ciliary sulcus IOL implantation. Compared with the sulcus group, the capsular group displayed signif- icantly lower MAE and higher percentage of eyes within +/- 0.50 D of PE (MAE: 0.90 vs 1.56 D; +/- 0.50 D: 40.40% vs 14.29%, both P <.001). The eyes receiv- ing in-the-bag IOL implantation (sulcus IOL implanta- tion fi: -1.060, 95% CI:-1.415 to-0.705; P <.001), unilateral ( fi: 0.647, 95% CI: 0.144-1.150; P=.012), or with deeper anterior chamber depth ( fi: 0.362, 95% CI: 0.068-0.656; P=.016) were prone to maintain hy- peropia (PE > 0). To reduce PE, when the predicted cap- sular IOL power was between 11.50 and 30.00 D, the power of a sulcus-implanted IOL should be reduced by 0.50 to 2.50 D accordingly (the exact amount of reduc- tion is positively related to the predicted power).center dot CONCLUSIONS: In-the-bag implantation yielded smaller PE in pediatric eyes undergoing secondary IOL implan- tation. Adjustment of IOL power for ciliary sulcus im- plantation is required to reduce PE, and the amount of adjustment is positively correlated with the IOL power predicted by SRK/T formula. (Am J Ophthal- mol 2023;249: 137-143.(c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
[21]   Pediatric bag-in-the-lens intraocular lens implantation: Long-term follow-up [J].
Van Looveren, Jan ;
Dhubhghaill, Sorcha Ni ;
Godts, Daisy ;
Bakker, Ellen ;
De Veuster, Ilse ;
Mathysen, Danny G. P. ;
Tassignon, Marie-Jose .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08) :1685-1692
[22]   Long-Term Postoperative Outcomes Following Cionni Ring and In-the-Bag Intraocular Lens Implantation in Eyes With Subluxated Lenses [J].
Sandhu, Rasikpriya ;
Shankar, Vijayvarschini ;
Vasavada, Vaishali ;
Vasavada, Shail ;
Vasavada, Abhay R. ;
Vasavada, Viraj A. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 268 :136-142
[23]   Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator [J].
Jasman, Azlyn-Azwa ;
Shaharuddin, Bakiah ;
Noor, Raja-Azmi M. ;
Ismail, Shatriah ;
Ghani, Zulkifli A. ;
Embong, Zunaina .
BMC OPHTHALMOLOGY, 2010, 10
[24]   Predictability of formulae for intraocular lens power calculation according to the age of implantation in paediatric cataract [J].
Lee, Byung Joo ;
Lee, Sang-Mok ;
Kim, Jeong Hun ;
Yu, Young Suk .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (01) :106-111
[25]   Capsular Tension Ring Implantation for Intraocular Lens Power Calculation in Highly Myopic Eyes: Secondary Analysis of a Randomized Clinical Trial [J].
Lin, Haowen ;
Zhang, Jiaqing ;
Jin, Aixia ;
Zhang, Yifan ;
Zhang, Yu ;
Jin, Ling ;
Xu, Yifan ;
Xie, Xiaohang ;
Qiu, Xiaozhang ;
Dai, Boyufei ;
Tan, Xuhua ;
Luo, Lixia ;
Liu, Yizhi .
JAMA OPHTHALMOLOGY, 2025,
[26]   Intraocular lens tilt and decentration in secondary ciliary sulcus implantation in paediatric eyes: A 3-year prospective study [J].
Yu, Yinglin ;
Wang, Lanhua ;
Tan, Yuan ;
Xu, Chaoqun ;
Chen, Hui ;
Zou, Yingshi ;
Jin, Guangming ;
Xu, Jingmin ;
Jin, Ling ;
Wang, Zhenyu ;
Luo, Lixia ;
Chen, Weirong ;
Liu, Yizhi ;
Liu, Zhenzhen .
ACTA OPHTHALMOLOGICA, 2024, 102 (05) :e805-e812
[27]   Precision of bag-in-the-lens intraocular lens power calculation in different age groups of pediatric cataract patients: Report of the Giessen Pediatric Cataract Study Group [J].
Lytvynchuk, Lyubomyr M. ;
Thiele, Maximilian, V ;
Schmidt, Werner ;
Lorenz, Birgit .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10) :1372-1379
[28]   Accuracy of Intraocular Lens Power Calculation in Eyes Filled with Silicone Oil [J].
Kanclerz, Piotr ;
Grzybowski, Andrzej .
SEMINARS IN OPHTHALMOLOGY, 2019, 34 (05) :392-397
[29]   Accuracy of new and standard intraocular lens power calculations formulae in Saudi pediatric patients [J].
An-Nakhli, Fouad Raja .
TAIWAN JOURNAL OF OPHTHALMOLOGY, 2019, 9 (01) :37-42
[30]   Intraocular lens implantation as an isolated risk factor for secondary glaucoma in pediatric patients [J].
Yagev, Ronit ;
Khatib, Nur ;
Barrett, Chiya ;
Yotam, Lior ;
Lifshitz, Tova ;
Tsumi, Erez .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2019, 54 (05) :621-625