Accuracy of Intraocular Lens Power Calculation in Pediatric Secondary Implantation: In-the-Bag Versus Sulcus Placement

被引:1
|
作者
Liu, Zhenzhen [1 ,2 ,3 ,4 ]
Zou, Yingshi [2 ,3 ,4 ]
Yu, Yinglin [2 ,3 ,4 ]
Qu, Bo [2 ,3 ,4 ]
Jin, Ling [2 ,3 ,4 ]
Tan, Yuan [2 ,3 ,4 ]
Chen, Hui [2 ,3 ,4 ]
Xu, Jingmin [2 ,3 ,4 ]
Lin, Zhuoling [2 ,3 ,4 ]
Li, Jing [2 ,3 ,4 ]
Liu, Jianping [2 ,3 ,4 ]
Luo, Lixia [2 ,3 ,4 ]
Chen, Weirong [2 ,3 ,4 ]
Liu, Yizhi [1 ,2 ,3 ,4 ]
机构
[1] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat sen Univ, Zhongshan Ophthalm Ctr, Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
[3] Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Guangdong, Peoples R China
[4] Guangdong Prov Clin Res Ctr Ocular Dis, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
REFRACTIVE OUTCOMES; IOL; COMPLICATIONS; CHALLENGES; CHILDREN; APHAKIA;
D O I
10.1016/j.ajo.2022.12.028
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To compare the effects of secondary in-the- bag vs ciliary sulcus intraocular lens (IOL) implantation on the accuracy of IOL power calculation in pediatric eyes.center dot DESIGN: Prospective nonrandomized interventional study.center dot METHODS: Pediatric aphakic eyes that underwent ei- ther in-the-bag or ciliary sulcus secondary IOL implan- tation were included. The mean prediction error (PE), mean absolute error (MAE), median absolute error, and percentages of eyes with PE within +/- 0.25 diopter (D), +/- 0.50 D, +/- 0.75 D, and +/- 1.00 D were calculated and compared using SRK/T formula.center dot RESULTS: One hundred fourteen eyes (38.26%) re- ceived in-the-bag IOL implantation and 184 (61.74%) underwent ciliary sulcus IOL implantation. Compared with the sulcus group, the capsular group displayed signif- icantly lower MAE and higher percentage of eyes within +/- 0.50 D of PE (MAE: 0.90 vs 1.56 D; +/- 0.50 D: 40.40% vs 14.29%, both P <.001). The eyes receiv- ing in-the-bag IOL implantation (sulcus IOL implanta- tion fi: -1.060, 95% CI:-1.415 to-0.705; P <.001), unilateral ( fi: 0.647, 95% CI: 0.144-1.150; P=.012), or with deeper anterior chamber depth ( fi: 0.362, 95% CI: 0.068-0.656; P=.016) were prone to maintain hy- peropia (PE > 0). To reduce PE, when the predicted cap- sular IOL power was between 11.50 and 30.00 D, the power of a sulcus-implanted IOL should be reduced by 0.50 to 2.50 D accordingly (the exact amount of reduc- tion is positively related to the predicted power).center dot CONCLUSIONS: In-the-bag implantation yielded smaller PE in pediatric eyes undergoing secondary IOL implan- tation. Adjustment of IOL power for ciliary sulcus im- plantation is required to reduce PE, and the amount of adjustment is positively correlated with the IOL power predicted by SRK/T formula. (Am J Ophthal- mol 2023;249: 137-143.(c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [1] In-the-Bag Versus Ciliary Sulcus Secondary Intraocular Lens Implantation for Pediatric Aphakia: A Prospective Comparative Study
    Liu, Zhenzhen
    Lin, Haotian
    Jin, Guangming
    Tan, Xuhua
    Qu, Bo
    Jin, Ling
    Chen, Xiaoyun
    Wang, Wei
    Han, Xiaotong
    Xu, Jingmin
    Ying, Guishuang
    Han, Ying
    He, Mingguang
    Congdon, Nathan
    Chen, Weirong
    Luo, Lixia
    Liu, Yizhi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 236 : 183 - 192
  • [2] In-the-bag secondary intraocular lens implantation in children
    Wilson, ME
    Englert, JA
    Greenwald, MJ
    JOURNAL OF AAPOS, 1999, 3 (06): : 350 - 355
  • [3] Safety and efficacy in pediatric secondary intraocular lens implantation, in-the-bag versus sulcus implantation: a multicenter, single-blinded randomized controlled trial
    Yingshi Zou
    Ling Jin
    Bo Qu
    Hui Chen
    Mingbing Zeng
    Xia Li
    Xinhua Liu
    Lixia Luo
    Zhenzhen Liu
    Yizhi Liu
    Trials, 24
  • [4] Safety and efficacy in pediatric secondary intraocular lens implantation, in-the-bag versus sulcus implantation: a multicenter, single-blinded randomized controlled trial
    Zou, Yingshi
    Jin, Ling
    Qu, Bo
    Chen, Hui
    Zeng, Mingbing
    Li, Xia
    Liu, Xinhua
    Luo, Lixia
    Liu, Zhenzhen
    Liu, Yizhi
    TRIALS, 2023, 24 (01)
  • [5] Pigmentary glaucoma secondary to in-the-bag intraocular lens implantation
    Boutboul, Sandrine
    Letaief, Imene
    Lalloum, Franck
    Puech, Michel
    Borderie, Vincent
    Laroche, Laurent
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09): : 1595 - 1597
  • [6] Delayed in-the-bag implantation of intraocular lens
    Chen, Yung-Jen
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (01): : 95 - 97
  • [7] Intraocular pressure after extracapsular cataract extraction and posterior chamber lens implantation - Sulcus versus in-the-bag fixation
    Kampmeier, J
    Kurz, S
    Schutte, E
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 211 (02) : 101 - 105
  • [8] In-the-Bag Intraocular Lens Placement via Secondary Capsulorhexis with Radiofrequency Diathermy in Pediatric Aphakic Eyes
    Luo, Lixia
    Lin, Haotian
    Chen, Weirong
    Wang, Chunxiao
    Zhang, Xinyu
    Tang, Xiangchen
    Liu, Jianping
    Congdon, Nathan
    Chen, Jingjing
    Lin, Zhuoling
    Liu, Yizhi
    PLOS ONE, 2013, 8 (04):
  • [9] In-the-bag hyphema after intraocular lens implantation
    Ohmi, S
    Takagishi, C
    Hashizume, N
    Saika, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (06): : 755 - 758
  • [10] The triple procedure: in the bag placement versus ciliary sulcus placement of the intraocular lens
    Borderie, VM
    Touzeau, O
    Bourcier, T
    Carvajal-Gonzalez, S
    Laroche, L
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (04) : 458 - 462