Monolithic capsule phase microextraction prior to gas chromatography-mass spectrometry for the determination of organochlorine pesticides in environmental water samples

被引:9
作者
Ferracane, Antonio [1 ,2 ]
Manousi, Natalia [2 ,3 ]
Kabir, Abuzar [4 ]
Furton, Kenneth G. [4 ]
Tranchida, Peter Q. [1 ]
Zachariadis, George A. [3 ]
Plotka-Wasylka, Justyna [5 ,6 ]
Mondello, Luigi [1 ,7 ]
Samanidou, Victoria F. [3 ]
Rosenberg, Erwin [2 ]
机构
[1] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[2] Vienna Univ Technol, Inst Chem Technol & Analyt, A-1060 Vienna, Austria
[3] Aristotle Univ Thessaloniki, Dept Chem, Lab Analyt Chem, Thessaloniki 54124, Greece
[4] Florida Int Univ, Dept Chem & Biochem, Miami, FL USA
[5] Gdansk Univ Technol, Fac Chem, Dept Analyt Chem, 1-12 G Narutowicza St, PL-80233 Gdansk, Poland
[6] Gdansk Univ Technol, BioTechMed Ctr, 1-12 G Narutowicza St, PL-80233 Gdansk, Poland
[7] Univ Messina, Chromaleont Srl, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
关键词
Organochlorine pesticides; Capsule phase microextraction; Water; Sample preparation; GC-MS; Monolithic sorbents; EXTRACTION; NANOPARTICLES; FRAMEWORK;
D O I
10.1016/j.microc.2022.108355
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a capsule phase microextraction (CPME) protocol followed by gas chromatography-mass spec-trometry is proposed for the accurate and sensitive monitoring of organochlorine pesticides (OCPs) in envi-ronmental water samples. Different monolithic sol-gel encapsulated sorbents were compared and monolithic sol-gel poly(ethylene glycol)-based sorbent incorporated into porous microextraction capsules resulted in the highest extraction efficiency. Following the selection of the microextraction device, the CPME conditions were optimized, while linearity, limits detection (LODs), limits of quantification (LOQs), accuracy, and precision were the figures-of-merit measured. Under optimum conditions the LODs for the OCPs ranged between 0.01 ng mL-1 and 0.03 ng mL-1. The relative standard deviations were better than 5.3 % and 9.2 % for intra-day and inter-day study, respectively. The relative recoveries ranged between 90.5 and 105.2 % (intra-day) and 93.0-105.0 % (inter-day), demonstrating good method trueness. Finally, the proposed protocol was implemented for the monitoring of OCPs in tap, river, pond, and lake water. The developed method presents better analytical features than existing methods.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry
    Garrido Frenich, Antonia
    Romero-Gonzalez, R.
    Martinez Vidal, Jose Luis
    Martinez Ocana, R.
    Baquero Feria, P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (06) : 2043 - 2059
  • [42] Application of pneumatic nebulization single-drop microextraction for the determination of organophosphorous pesticides by gas chromatography-mass spectrometry
    Wang, Yeqiang
    Wang, Ziming
    Zhang, Huihui
    Shi, Yuhua
    Ren, Ruibing
    Zhang, Hanqi
    Yu, Yong
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (15) : 1880 - 1885
  • [43] Dispersive Liquid-Liquid Microextraction Combined with Gas Chromatography-Mass Spectrometry for the Determination of Multiple Pesticides in Celery
    Wang, Yaru
    Miao, Xuexue
    Wei, Haifeng
    Liu, Deyun
    Xia, Gaofeng
    Yang, Xiaoyun
    FOOD ANALYTICAL METHODS, 2016, 9 (08) : 2133 - 2141
  • [44] Microextraction in Packed Sorbent for the Determination of Pesticides in Honey Samples by Gas Chromatography Coupled to Mass Spectrometry
    Salami, Fernanda H.
    Queiroz, Maria Eugenia C.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2013, 51 (10) : 899 - 904
  • [45] Agarose film liquid phase microextraction combined with gas chromatography-mass spectrometry for the determination of polycyclic aromatic hydrocarbons in water
    Sanagi, Mohd Marsin
    Loh, Saw Hong
    Ibrahim, Wan Aini Wan
    Hasan, Mohamed Noor
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1262 : 43 - 48
  • [46] Two dispersive liquid-liquid microextraction methods coupled with gas chromatography-mass spectrometry for the determination of organophosphorus pesticides in field water
    Chu, Shang-Ping
    Huang, Chun-Kai
    Chen, Pai-Shan
    Huang, Shang-Da
    ENVIRONMENTAL CHEMISTRY, 2014, 11 (06) : 661 - 672
  • [47] Hollow fibre-based liquid-phase microextraction technique combined with gas chromatography-mass spectrometry for the determination of pyrethroid insecticides in water samples
    San Roman, I.
    Alonso, M. L.
    Bartolome, L.
    Alonso, R. M.
    TALANTA, 2012, 100 : 246 - 253
  • [48] Multi-residue determination of organochlorine pesticides in vegetables in Kirklareli, Turkey by gas chromatography-mass spectrometry
    Ozcan, Cemile
    Balkan, Seda
    JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 72 (07) : 761 - 769
  • [49] Study on the Performance of the Headspace Liquid-Phase Microextraction, Gas Chromatography-Mass Spectrometry in the Determination of Sorbic and Benzoic Acids in Soft Drinks and Environmental Water Samples
    Farahani, Hadi
    Ganjali, Mohammad Reza
    Dinarvand, Rassoul
    Norouzi, Parviz
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (07) : 2633 - 2639
  • [50] Simultaneous and rapid determination of three organophosphorus pesticides from vegetable and cereal samples with a magnetic dispersive solid-phase microextraction method by gas chromatography-mass spectrometry
    Sefati, Bahareh
    Masrournia, Mahboubeh
    Beheshti, Hamed Reza
    Feizy, Javad
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 104 (19) : 7457 - 7473