Monolithic capsule phase microextraction prior to gas chromatography-mass spectrometry for the determination of organochlorine pesticides in environmental water samples

被引:9
|
作者
Ferracane, Antonio [1 ,2 ]
Manousi, Natalia [2 ,3 ]
Kabir, Abuzar [4 ]
Furton, Kenneth G. [4 ]
Tranchida, Peter Q. [1 ]
Zachariadis, George A. [3 ]
Plotka-Wasylka, Justyna [5 ,6 ]
Mondello, Luigi [1 ,7 ]
Samanidou, Victoria F. [3 ]
Rosenberg, Erwin [2 ]
机构
[1] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[2] Vienna Univ Technol, Inst Chem Technol & Analyt, A-1060 Vienna, Austria
[3] Aristotle Univ Thessaloniki, Dept Chem, Lab Analyt Chem, Thessaloniki 54124, Greece
[4] Florida Int Univ, Dept Chem & Biochem, Miami, FL USA
[5] Gdansk Univ Technol, Fac Chem, Dept Analyt Chem, 1-12 G Narutowicza St, PL-80233 Gdansk, Poland
[6] Gdansk Univ Technol, BioTechMed Ctr, 1-12 G Narutowicza St, PL-80233 Gdansk, Poland
[7] Univ Messina, Chromaleont Srl, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
关键词
Organochlorine pesticides; Capsule phase microextraction; Water; Sample preparation; GC-MS; Monolithic sorbents; EXTRACTION; NANOPARTICLES; FRAMEWORK;
D O I
10.1016/j.microc.2022.108355
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a capsule phase microextraction (CPME) protocol followed by gas chromatography-mass spec-trometry is proposed for the accurate and sensitive monitoring of organochlorine pesticides (OCPs) in envi-ronmental water samples. Different monolithic sol-gel encapsulated sorbents were compared and monolithic sol-gel poly(ethylene glycol)-based sorbent incorporated into porous microextraction capsules resulted in the highest extraction efficiency. Following the selection of the microextraction device, the CPME conditions were optimized, while linearity, limits detection (LODs), limits of quantification (LOQs), accuracy, and precision were the figures-of-merit measured. Under optimum conditions the LODs for the OCPs ranged between 0.01 ng mL-1 and 0.03 ng mL-1. The relative standard deviations were better than 5.3 % and 9.2 % for intra-day and inter-day study, respectively. The relative recoveries ranged between 90.5 and 105.2 % (intra-day) and 93.0-105.0 % (inter-day), demonstrating good method trueness. Finally, the proposed protocol was implemented for the monitoring of OCPs in tap, river, pond, and lake water. The developed method presents better analytical features than existing methods.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Determination of organotin compounds in water by headspace solid phase microextraction with gas chromatography-mass spectrometry
    Chou, CC
    Lee, MR
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1064 (01) : 1 - 8
  • [22] Determination of 27 pesticides in wine by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry
    Chen, Bo
    Wu, Feng-qi
    Wu, Wei-dong
    Jin, Bao-hui
    Xie, Li-qi
    Feng, Wen
    Ouyang, Gangfeng
    MICROCHEMICAL JOURNAL, 2016, 126 : 415 - 422
  • [23] Sensitive determination of polybrominated diphenyl ethers in environmental water samples with etched stainless steel wire based on solid-phase microextraction prior to gas chromatography-mass spectrometry
    Chen, Xiang-Feng
    Cheng, Chuan-Ge
    Wang, Xia
    Zhao, Ru-Song
    ANALYTICAL METHODS, 2012, 4 (09) : 2908 - 2913
  • [24] Determination of organochlorine pesticides in sewage sludge by matrix solid-phase dispersion and gas chromatography-mass spectrometry
    Sanchez-Brunete, Consuelo
    Miguel, Esther
    Tadeo, Jose L.
    TALANTA, 2008, 74 (05) : 1211 - 1217
  • [25] Determination of pesticides in tea by isotope dilution gas chromatography-mass spectrometry coupled with solid-phase microextraction
    Feng, Jie
    Tang, Hua
    Chen, Dazhou
    Wang, Guannan
    Li, Lei
    ANALYTICAL METHODS, 2012, 4 (12) : 4198 - 4203
  • [26] Application of multiwalled carbon nanotubes for the preconcentration and determination of organochlorine pesticides in water samples by gas chromatography with mass spectrometry
    Taghani, Abdollah
    Goudarzi, Naaser
    Bagherian, Ghadamali
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (21) : 4219 - 4226
  • [27] Application of isotope dilution to the determination of anthracene in environmental samples by headspace solid-phase microextraction and gas chromatography-mass spectrometry
    Vilchez, Jose Luis
    Prieto, Avismelsi
    Araujo, Lilia
    Navalon, Alberto
    MICROCHIMICA ACTA, 2006, 155 (3-4) : 435 - 439
  • [28] Analyses of nitrobenzene, benzene and aniline in environmental water samples by headspace solid phase microextraction coupled with gas chromatography-mass spectrometry
    Chen, Ming
    Yin, Yongguang
    Tai, Chao
    Zhang, Qinghua
    Liu, Jiyan
    Hu, Jingtian
    Jiang, Guibin
    CHINESE SCIENCE BULLETIN, 2006, 51 (13): : 1648 - 1651
  • [29] Determination of Organophosphorus Pesticides in Juice and Water by Modified Continuous Sample Drop Flow Microextraction Combined with Gas Chromatography-Mass Spectrometry
    Moinfar, Soleyman
    Jamil, Lazgin Abdi
    Sami, Helan Zeyad
    FOOD ANALYTICAL METHODS, 2020, 13 (05) : 1050 - 1059
  • [30] Determination of four antiepileptic drugs with solvent assisted dispersive solid phase microextraction - Gas chromatography-mass spectrometry in human urine samples
    Mohammadi, Parisa
    Masrournia, Mahboubeh
    Es'haghi, Zarrin
    Pordel, Mehdi
    MICROCHEMICAL JOURNAL, 2020, 159