Risk Factors for the Drift Phenomenon in O-arm Navigation-Assisted Pedicle Screw Placement during Spinal Deformity Surgery

被引:3
|
作者
Zhao, Jianquan [1 ]
Jiang, Heng [1 ]
Zhuge, Yingjie [2 ]
Gao, Rui [1 ]
Wang, Ce [1 ]
Ma, Jun [1 ]
Zhou, Xuhui [1 ]
机构
[1] Second Mil Med Univ, Shanghai Changzheng Hosp, Dept Orthopaed Surg, Shanghai 200003, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Dept Orthopaed Surg, Shanghai, Peoples R China
关键词
Deformity; Drift phenomenon; Navigation; O-arm; Pedicle screw; ANTERIOR VERTEBRAL HEIGHT; FREE-HAND; FRACTURED VERTEBRA; ACCURACY; SCOLIOSIS; RESTORATION; FLUOROSCOPY; INSERTION; FIXATION; SAFETY;
D O I
10.1111/os.13557
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Intraoperative O-arm navigation systems improve the accuracy of spinal instrumentation placement. However, deviation of the pedicle screw from the guide line might occur. The aim of the present study was to explore the causes of and countermeasures for the drift phenomenon during pedicle screw implantation with the aid of an O-arm three-dimensional navigation system in spinal deformity surgery. Methods This was a retrospective analysis of 341 patients with spinal deformity who underwent O-arm navigation system-assisted pedicle screw placement from July 2015 to June 2019. The patient's general condition, Cobb angle, apical vertebra position, softness index, spinal release status, fixed reference frame position, and distance between the navigation vertebral body and the reference frame were collected and compared by independent-samples t test or Pearson's chi-square analysis. The potential risk factors for the drift phenomenon were identified using binary logistic regression analysis. Results The drift phenomenon occurred in 57 patients during the first navigation-assisted pedicle screw placement, for an incidence of 16.7% (57/341). There were significant differences in factors such as the apical vertebra position, softness index, spinal release status, and distance between the vertebral body and the reference frame when the drift phenomenon occurred (P < 0.05). Binary logistic regression analysis showed that the softness index, spinal release status, and distance between the vertebral body and the reference frame when drifting occurred were independent risk factors for the drift phenomenon during O-arm navigation-assisted pedicle screw placement. Conclusion During the use of an O-arm navigation system to assist with pedicle screw placement, pedicle screws should not be placed away from the reference frame, and spinal osteotomy and release should be performed after pedicle screw placement. In addition, the accuracy of O-arm navigation-assisted pedicle screw placement will be affected more in those with larger softness indices.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [21] Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique
    Jin, Mengran
    Liu, Zhen
    Liu, Xingyong
    Yan, Huang
    Han, Xiao
    Qiu, Yong
    Zhu, Zezhang
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1729 - 1737
  • [22] Robot-assisted versus navigation-assisted screw placement in spinal vertebrae
    Tong Yu
    Jian-Hang Jiao
    Yang Wang
    Qing-Yu Wang
    Wei-Bo Jiang
    Zhong-Han Wang
    Min-Fei Wu
    International Orthopaedics, 2023, 47 : 527 - 532
  • [23] Comparison of rostral facet joint violations in robotic- and navigation-assisted pedicle screw placement for adult lumbar spine instrumentation
    Nilssen, Paal K.
    Narendran, Nakul
    Skaggs, David L.
    Tuchman, Alexander
    Walker, Corey T.
    Perry, Tiffany G.
    SPINE JOURNAL, 2024, 24 (11): : 2102 - 2109
  • [24] Safety and accuracy of cannulated pedicle screw placement in scoliosis surgery: a comparison of robotic-navigation, O-arm-based navigation, and freehand techniques
    Li, Chao
    Wang, Zheng
    Li, Donglai
    Tian, Yonghao
    Yuan, Suomao
    Wang, Lianlei
    Liu, Xinyu
    EUROPEAN SPINE JOURNAL, 2023, 32 (09) : 3094 - 3104
  • [25] Accuracy and Safety in Screw Placement in the High Cervical Spine Retrospective Analysis of O-arm-based Navigation-assisted C1 Lateral Mass and C2 Pedicle Screws
    Hur, Jung-Woo
    Kim, Jin-Sung
    Ryu, Kyeong-Sik
    Shin, Myeong-Hoon
    CLINICAL SPINE SURGERY, 2019, 32 (04): : E193 - E199
  • [26] A Novel Intraoperative CT Navigation System for Spinal Fusion Surgery in Lumbar Degenerative Disease: Accuracy and Safety of Pedicle Screw Placement
    Kanno, Haruo
    Handa, Kyoichi
    Murotani, Motoki
    Ozawa, Hiroshi
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)
  • [27] Case series: O-arm navigation assisted by the Wiltse approach improves the accuracy of pedicle screw placement in ankylosing spondylitis combined with thoracolumbar fractures
    Li, Chang-Ming
    Zhao, Shi-Jie
    Xu, Jian-Zhu
    Li, Qiang
    Quan, Ren-Fu
    Deng, Xiao-Mei
    MEDICINE, 2023, 102 (52) : E36807
  • [28] Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques
    Silbermann, J.
    Riese, F.
    Allam, Y.
    Reichert, T.
    Koeppert, H.
    Gutberlet, M.
    EUROPEAN SPINE JOURNAL, 2011, 20 (06) : 875 - 881
  • [29] Efficacy and safety for combination of t-EMG with O-arm assisted pedicle screw placement in neurofibromatosis type I scoliosis surgery
    Xiexiang Shao
    Zifang Huang
    Jingfan Yang
    Yaolong Deng
    Junlin Yang
    Wenyuan Sui
    Journal of Orthopaedic Surgery and Research, 16
  • [30] Comparison of Cranial Facet Joint Violation Rates Between Open and Percutaneous Pedicle Screw Placement Using Intraoperative 3-D CT (O-arm) Computer Navigation
    Yson, Sharon C.
    Sembrano, Jonathan N.
    Sanders, Peter C.
    Santos, Edward Rainier G.
    Ledonio, Charles Gerald T.
    Polly, David W., Jr.
    SPINE, 2013, 38 (04) : E251 - E258