Risk Factors for the Drift Phenomenon in O-arm Navigation-Assisted Pedicle Screw Placement during Spinal Deformity Surgery

被引:3
|
作者
Zhao, Jianquan [1 ]
Jiang, Heng [1 ]
Zhuge, Yingjie [2 ]
Gao, Rui [1 ]
Wang, Ce [1 ]
Ma, Jun [1 ]
Zhou, Xuhui [1 ]
机构
[1] Second Mil Med Univ, Shanghai Changzheng Hosp, Dept Orthopaed Surg, Shanghai 200003, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Dept Orthopaed Surg, Shanghai, Peoples R China
关键词
Deformity; Drift phenomenon; Navigation; O-arm; Pedicle screw; ANTERIOR VERTEBRAL HEIGHT; FREE-HAND; FRACTURED VERTEBRA; ACCURACY; SCOLIOSIS; RESTORATION; FLUOROSCOPY; INSERTION; FIXATION; SAFETY;
D O I
10.1111/os.13557
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Intraoperative O-arm navigation systems improve the accuracy of spinal instrumentation placement. However, deviation of the pedicle screw from the guide line might occur. The aim of the present study was to explore the causes of and countermeasures for the drift phenomenon during pedicle screw implantation with the aid of an O-arm three-dimensional navigation system in spinal deformity surgery. Methods This was a retrospective analysis of 341 patients with spinal deformity who underwent O-arm navigation system-assisted pedicle screw placement from July 2015 to June 2019. The patient's general condition, Cobb angle, apical vertebra position, softness index, spinal release status, fixed reference frame position, and distance between the navigation vertebral body and the reference frame were collected and compared by independent-samples t test or Pearson's chi-square analysis. The potential risk factors for the drift phenomenon were identified using binary logistic regression analysis. Results The drift phenomenon occurred in 57 patients during the first navigation-assisted pedicle screw placement, for an incidence of 16.7% (57/341). There were significant differences in factors such as the apical vertebra position, softness index, spinal release status, and distance between the vertebral body and the reference frame when the drift phenomenon occurred (P < 0.05). Binary logistic regression analysis showed that the softness index, spinal release status, and distance between the vertebral body and the reference frame when drifting occurred were independent risk factors for the drift phenomenon during O-arm navigation-assisted pedicle screw placement. Conclusion During the use of an O-arm navigation system to assist with pedicle screw placement, pedicle screws should not be placed away from the reference frame, and spinal osteotomy and release should be performed after pedicle screw placement. In addition, the accuracy of O-arm navigation-assisted pedicle screw placement will be affected more in those with larger softness indices.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [11] One-step Minimally Invasive Pedicle Screw Instrumentation Using O-Arm and Stealth Navigation
    Kleck, Christopher J.
    Johnson, Christopher
    Akiyama, Michelle
    Burger, Evalina L.
    Cain, Christopher J.
    Patel, Vikas V.
    CLINICAL SPINE SURGERY, 2018, 31 (05): : 197 - 202
  • [12] O-Arm Assisted Cervicothoracic Spine Pedicle Screw Placement Accuracy Is Higher Than C-Arm Fluoroscopy
    Inoue, Tomohisa
    Wada, Keiji
    Tominaga, Ayako
    Tamaki, Ryo
    Hirota, Tomoya
    Okazaki, Ken
    WORLD NEUROSURGERY, 2022, 158 : E996 - E1001
  • [13] Clinical Assessment of Percutaneous Lumbar Pedicle Screw Placement Using the O-Arm Multidimensional Surgical Imaging System
    Houten, John K.
    Nasser, Rani
    Baxi, Nrupen
    NEUROSURGERY, 2012, 70 (04) : 990 - 995
  • [14] Pedicle Perforation While Inserting Screws Using O-arm Navigation During Surgery for Adolescent Idiopathic Scoliosis Risk Factors and Effect of Insertion Order
    Oba, Hiroki
    Ebata, Shigeto
    Takahashi, Jun
    Koyama, Kensuke
    Uehara, Masashi
    Kato, Hiroyuki
    Haro, Hirotaka
    Ohba, Tetsuro
    SPINE, 2018, 43 (24) : E1463 - E1468
  • [15] O-arm navigation versus C-arm guidance for pedicle screw placement in spine surgery: a systematic review and meta-analysis
    Weili Feng
    Weihao Wang
    Shubiao Chen
    Kezhou Wu
    Hu Wang
    International Orthopaedics, 2020, 44 : 919 - 926
  • [16] Learning curve across 2000 thoracolumbar pedicle screw placements using O-arm navigation: technical difficulties and their solutions
    Hadgaonkar, Shailesh
    Gupta, Alok
    Aiyer, Siddharth
    Bhilare, Pramod
    Sancheti, Parag
    EUROPEAN SPINE JOURNAL, 2023, 32 (11) : 3753 - 3763
  • [17] Safety and Accuracy of Freehand Pedicle Screw Placement and the Role of Intraoperative O-Arm A Single-Institution Experience
    Alomari, Safwan
    Lubelski, Daniel
    Lehner, Kurt
    Tang, Anthony
    Wolinsky, Jean-Paul
    Theodore, Nicholas
    Sciubba, Daniel M.
    Lo, Sheng-fu Larry
    Belzberg, Allan
    Weingart, Jon
    Witham, Timothy
    Gokaslan, Ziya L.
    Bydon, Ali
    SPINE, 2023, 48 (03) : 180 - 188
  • [18] Safety and risk factors of TINAVI robot-assisted percutaneous pedicle screw placement in spinal surgery
    Zhang, Ren-Jie
    Zhou, Lu-Ping
    Zhang, Lai
    Zhang, Hua-Qing
    Zhang, Jian-Xiang
    Shen, Cai-Liang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [19] Intra-operative cone-beam CT (O-arm) and stereotactic navigation in acute spinal trauma surgery
    Schouten, Rowan
    Lee, Robert
    Boyd, Michael
    Paquette, Scott
    Dvorak, Marcel
    Kwon, Brian K.
    Fisher, Charles
    Street, John
    JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (08) : 1137 - 1143
  • [20] Comparison of the Accuracy of Pedicle Screw Placement Using a Fluoroscopy-Assisted Free-Hand Technique with Robotic-Assisted Navigation Using an O-Arm or 3D C-Arm in Scoliosis Surgery
    Li, Chao
    Li, Hao
    Su, Junxiao
    Wang, Zheng
    Li, Donglai
    Tian, Yonghao
    Yuan, Suomao
    Wang, Lianlei
    Liu, Xinyu
    GLOBAL SPINE JOURNAL, 2024, 14 (04) : 1337 - 1346